Siechem Technologies Pvt. Ltd
Siechem Technologies Pvt. Ltd
Errabalu Chetty Street, Chennai, Tamil Nadu
SEND SMS
SEND EMAIL

Jelly Filled Telecom Cables

Leading Manufacturer of jelly filled telecommunication cables, jelly filled telecom instrumentation cables and jelly filled telecom cables from Chennai.

Jelly Filled Telecommunication Cables

Jelly Filled Telecommunication Cables
  • Jelly Filled Telecommunication Cables
Ask For Price
Application:
  • These cables are used for distribution in Exchange area and usually conduit or direct burial application
  • Suitable for underground applications.
  • Twisted Pair, Triad/Quad construction with short pitch individual aluminum tape shielding, offers excellent immunity to crosstalk and low frequency (up to 10 KHz) electrostatic and electromagnetic interference.
  • For BS 5308, these cables are designed for use in communication and instrumentation applications in and around process industries like oil exploration, cement, paper, steel, power generation and others.

Product Construction:
  • Conductor: Soft-annealed solid electrolytic copper
  • Insulation: Polyethylene
  • Inner Sheath: Polyethylene
  • Armouring: Galvanised steel tape, double steel tape
  • Outer Sheath: Polyethylene, PVC ST1
  • Colour: As per customer spec
  • Multi-pair

Technical Data:
  • Specification: BSNL Spec. No. GR / CUG-01/03, Aug. 2003
  • Flame retardant (Fire Resistance) test as per IS: 10810-Part 61
  • Carbon black content, 2.5% min as per BS: 6234
  • Volume resistivity at 100°C is ≥ 1 x 1010 W.cm
  • Nominal mutual capacitance 0.05 mF/km
  • Capacitance unbalance between pairs ≤ 300 pF
  • Spark test voltage 3 kV AC
  • Laid up pairs flooded with water resistant jelly.
  • Longitudinally applied polyethylene coated aluminium moisture barrier tape
  • PE inner sheath / outer sheath, Spark test at 11 kV AC
  • Near end crosstalk between adjacent pairs – better than 55 dB
  • Far end cross-linked talk between adjacent pairs – better than 67.8 dB/km

Features:
  • Up to 2400 pairs
  • Uniformly drawn circular solid copper conductor
  • MDPE / HDPE extruded insulation
  • Insulation resistance not less than 5000 mW km (VR not less than 1×1015 W.cm)
Specifications:
Type no.Max.dia. of SpliceMin.dia.of SpliceMaximum permissible Splice openingCABLE TO WHICH APPLICABLE

(mm)(mm)(mm)0.4
(mm)
0.5
(mm)
0.63
(mm)
0.9
(mm)
TSF- 0428805
10
5
10
5
10
5
10
TSF- 1428225202020
TSF- 242835050505020
TSF- 3622235010010010050
TSF- 49230500200200200100
Request
Callback
Yes! I am interested
View PDF

Jelly Filled Telecommunication Cables

Jelly Filled Telecommunication Cables
  • Jelly Filled Telecommunication Cables
Ask For Price
Application:
  • These cables are used for distribution in Exchange area and usually conduit or direct burial application
  • Suitable for underground applications.
  • Twisted Pair, Triad/Quad construction with short pitch individual aluminum tape shielding, offers excellent immunity to cross talk and low frequency (upto 10 KHz) electrostatic and electromagnetic interference.
  • For BS 5308, these cables are designed for use in communication and instrumentation applications in and around process industries like oil exploration, cement, paper, steel, power generation and others.

Product Construction:
  • Conductor: Soft-annealed solid electrolytic copper
  • Insulation: Polyethylene
  • Inner Sheath: Polyethylene
  • Armouring: Galvanised steel tape, double steel tape
  • Outer Sheath: Polyethylene, PVC ST1
  • Multi-pair

Technical Data:

  • Flame retardant (Fire Resistance) test as per IS: 10810-Part 61
  • Carbon black content, 2.5% min as per BS: 6234
  • Volume resistivity at 100°C is ≥ 1 x 1010 W.cm
  • Nominal mutual capacitance 0.05 mF/km
  • Capacitance unbalance between pairs ≤ 300 pF
  • Spark test voltage 3 kV AC
  • Laid up pairs flooded with water resistant jelly.
  • Longitudinally applied polyethylene coated aluminium moisture barrier tape
  • PE inner sheath / outer sheath, Spark test at 11 kV AC
  • Near end cross talk between adjacent pairs – better than 55 dB
  • Far end cross-linked talk between adjacent pairs – better than 67.8 dB/km

Features:
  • Upto 2400 pairs
  • Uniformly drawn circular solid copper conductor
  • MDPE / HDPE extruded insulation
  • Insulation resistance not less than 5000 mW (VR not less than 1×1015 W cm)

Specifications:

Type no.Max.dia. of SpliceMin.dia.of SpliceMaximum permissible Splice openingCABLE TO WHICH APPLICABLE

(mm)(mm)(mm)0.4
(mm)
0.5
(mm)
0.63
(mm)
0.9
(mm)
TSF- 0428805
10
5
10
5
10
5
10
TSF- 1428225202020
TSF- 242835050505020
TSF- 3622235010010010050
TSF- 49230500200200200100
Request
Callback
Yes! I am interested

Jelly Filled Telecom Instrumentation Cables

Jelly Filled Telecom Instrumentation Cables
  • Jelly Filled Telecom Instrumentation Cables
Ask For Price
BS 5308 Jelly Filled Telecom Instrumentation Cables
Application:
  • For signal and data transmission used in measurement and control technology such as in control room at industrial plants, power stations, refineries, petrochemical plants.
  • Suitable for underground applications.
  • Twisted Pair, Triad/Quad construction with short pitch individual aluminum tape shielding, offers excellent immunity to cross talk and low frequency (upto 10 KHz) electrostatic and electromagnetic interference.
  • For BS 5308, these cables are designed for use in communication and instrumentation applications in and around process industries like oil exploration, cement, paper, steel, power generation and others.

Product Construction:
  • Conductor: Flexible / Stranded / Solid, Plain / Tinned
  • Insulation: PVC / HR PVC / Zero Halogen
  • Shielding : Al. Mylar tape
  • Drain wire : Annealed tinned copper wire
  • Armouring: GI wire / GI strip
  • Outer sheath: PVC / HR PVC / Zero Halogen

Technical Data:
  • Operating Temperature: PVC: -40°C to +70°C
  • HR PVC: -40 C to +105 C
  • Voltage Rating:300/500 V
  • Conductor Resistance at 20 C: IS 8130/(2013) – Ohm / Km
  • Insulation Resistance at 20??C: PVC – 25 MΩ (min)
  • Maximum AC Voltage Withstand: 1 kV
  • Mutual Capacitance of Pairs: 250 pF/m
  • Conductor to Screen Capacitance: 400 pF/m

Features:
  • High current carrying capacity
  • Low conductor resistance
  • Oil and flame resistance
  • Heat Resistant
  • Excellent flexibility
  • Ozone resistant
  • Exceptional mechanical properties

Specifications:
Cable Type12121212121212
Normal Thickness of sheath/ Bedding (mm)1.11.11.21.21.31.31.51.51.51.51.71.72.22.2
Normal Diameter over Sheath/ Bedding (mm)111114.214.220.120.123.523.526.326.331.331.340.740.7
Normal Size of Armour wire (mm)
0.9
1.25
1.6
1.6
1.6
2
2.5
Request
Callback
Yes! I am interested
View PDF

Jelly Filled Telecom Cables

Jelly Filled Telecom Cables
  • Jelly Filled Telecom Cables
Ask For Price

Product Details:

Minimum Order Quantity1 Meter
Conductor Diameter0.25mm
Number of Pairs25.0
Conductor TypeStranded
ArmouredYes

Siechem is India’s No.1 leading manufacturer & exporter of Telecommunication Cables. Equipped with most sophisticated, state-of-the-art jelly-filled telecommunication cable plant, fully equipped testing lab and highly skilled technical personnel, the cables are manufactured to every national and international standard covering from 5 pairs upto 2400 pairs with conductors of sizes 0.4mm / 0.5mm / 0.63mm and 0.9mm.These water resistant landline cables ensures best communication and data transmission needs throughout the year even during the hostile weather conditions

Features:
  • Upto 2400 pairs
  • Uniformly drawn circular solid copper conductor
  • MDPE / HDPE extruded insulation
  • Insulation resistance not less than 5000 mW.km (VR not less than 1x1015 W.cm)

Applications:

  • These cables are used for distribution in Exchange area and usually conduit or direct burial application

Product Construction:
  • Conductor: Soft-annealed solid electrolytic copper
  • Insulation: Polyethylene
  • Inner Sheath: Polyethylene
  • Armouring: Galvanized steel tape, double steel tape
  • Outer Sheath: Polyethylene, PVC ST1
  • Colour: As per customer spec

Technical Specifications:
  • Flame retardant (Fire Resistance) test as per IS : 10810-Part 61
  • Carbon black content, 2.5% min as per BS : 6234
  • Volume resistivity at 100°C is ≥ 1 x 1010 W.cm
  • Nominal mutual capacitance 0.05 mF/km
  • Capacitance unbalance between pairs ≤ 300 pF
  • Spark test voltage 3 kV AC
  • Laid up pairs flooded with water resistant jelly.
  • Longitudinally applied polyethylene coated aluminium moisture barrier tape
  • PE inner sheath / outer sheath, Spark test at 11 kV AC
  • Near end cross talk between adjacent pairs – better than 55 dB
  • Far end cross linked talk between adjacent pairs – better than 67.8 dB/km

Approvals:
  • ISO 9001, ISO 14001, OHSAS 18001
  • BSNL

 

Request
Callback
Yes! I am interested
View PDF
X
Looking for “Jelly Filled Telecom Cables”?


Reach Us
Arun Kumar (Executive Director)
No. 26/27, Errabalu Chetty Street
Chennai- 600001, Tamil Nadu, India


Call Us

Send E-mail

Send SMS