Siechem Technologies Pvt. Ltd
Siechem Technologies Pvt. Ltd
Errabalu Chetty Street, Chennai, Tamil Nadu
SEND SMS
SEND EMAIL

Standard Cables

Leading Manufacturer of fly standard cable, automotive engine harness wire, auto 125p cable, auto 180e-a wire, auto 180e-b cable and auto 210f- a wire from Chennai.

FLY Standard Cable

FLY Standard Cable
  • FLY Standard Cable
Ask For Price

Product Details:

Power/Voltage5 kV (r.m.s.)
Length 1.5 mm2

Application:
  • Low-tension electric wire for Automobiles.
  • Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper E-Cu ETP1 according to DIN EN 13602, bare conductor
  • Insulation: Plasticized PVC with properties according to ISO 6722, Class B, Lead free
  • Colour: As per customer order
  • Single core

Technical Data:
  • Temperature Range: – 40°C to +105°C (3000 Hours)
  • Test Voltage: 3 kV (r.m.s.) for cables < 0.5 mm2
  • 5 kV (r.m.s.) for cables ≥ 0.5 mm2
  • FL: Automotive cable
  • Y: PVC insulation
  • Standard: LV112
  • BMW GS 95007-1-1
  • VM 60306-1

Features:
  • Flame retardant
  • Highly resistant against acids, lyes, Petrol and diesel.
  • Flexible conductors with PVC thick wall insulation with increased mechanical strength.
  • Extra flexibility.

Specifications:

Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200C
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor
Diameter
Normal
Overall
Diameter Max.
Weight
Approx.

mm2nos.mmmmmmmmkg/kmAmps???/kmmeters
83306XX *0.5160.2110.62.3101537.1500
83308XX0.75240.211.20.62.5131924.7500
83310XX1320.211.350.62.7162218.5500
83313XX1.5300.261.70.63212812.7500
Request
Callback
Yes! I am interested
View PDF

Automotive Engine Harness Wire

Automotive Engine Harness Wire
  • Automotive Engine Harness Wire
Ask For Price

Product Details:

Black in colour60 V

Application:
  • For use in automotive engine compartment to withstand excessive heat and to give protection from engine fluids.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper construction
  • Insulation: EBXL Special polymer uni sheathed
  • Colour: As per customer order
  • Single core, Single layer insulation

Technical Data:
  • Temperature Range: – 40°C to +150°C (3000 Hours)
  • Voltage: 60 V
  • Scrape Abrasion: SA 2 as per volvo std 525-0001
  • Thermal Life, Heat Shock, Shrinkage, Ozone Resistance, Volume Resistivity etc as per ISO 6722.
  • Hot oil (ASTM1): No breakdown at 1 kV
  • Battery Acid Resistance: <1% swell
  • Auto Transmission Fluid (Dexon III)
  • Hydrolysis: Pass (35 days, 850C, 48V)
  • Salt spray test as per ASTM B 117-73

Technical Details:
  • ISO 6722
  • BMW GS.95
  • VW 60306
  • FORD, WSK – 1A348-A4
  • FIAT 9 91107

Features:
  • High-temperature resistance
  • Electron Beam Cross-Linked
  • Class D Compliant
  • Available in twisted pairs and triples
  • Thin wall designs
  • Excellent oil resistance at high temperature
  • T4 Rated (4000 hrs 1500 C)
  • Designed for 1500 C continuous use.

Specifications:

Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200 C
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor
Diameter
Max.
Overall DiameterWeight
Approx.
Min.NormalMax.

mm2nos.mmmmmmmmmmmmkg/kmAmps???/km
86005XX*0.3570.270.80.351.21.31.451352
86006XX0.5190.1910.351.41.51.671637.1
86008XX0.75190.231.20.351.71.81.992124.7
Request
Callback
Yes! I am interested
View PDF

Auto 125P Cable

Auto 125P Cable
  • Auto 125P Cable
Ask For Price
Application:
  • For use in automotive engine compartment to withstand excessive heat and to give protection from engine fluids.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper construction
  • Insulation: EBXL Special polymer uni sheathed
  • Colour: As per customer order
  • Single core, Single layer insulation

Technical Data:
  • Temperature Range: – 40°C to +150°C (3000 Hours)
  • Voltage: 60 V
  • Scrape Abrasion: SA 2 as per volvo std 525-0001
  • Thermal Life, Heat Shock, Shrinkage, Ozone Resistance, Volume Resistivity etc as per ISO 6722.
  • Hot oil (ASTM1): No breakdown at 1 kV
  • Battery Acid Resistance: <1% swell
  • Auto Transmission Fluid (Dexon III)
  • Hydrolysis: Pass (35 days, 850C, 48V)
  • Salt spray test as per ASTM B 117-73

Technical Details:
  • ISO 6722
  • BMW GS.95
  • VW 60306
  • FORD, WSK – 1A348-A4
  • FIAT 9 91107

Features:
  • High-temperature resistance
  • Electron Beam Cross-Linked
  • Class D Compliant
  • Available in twisted pairs and triples
  • Thin wall designs
  • Excellent oil resistance at high temperature
  • T4 Rated (4000 hrs  1500 C)
  • Designed for 1500 C continuous use.
  • Flame Retardant
  • Mechanically Robust

Specifications:

Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200C
Max.
Conductor
Resistance
at 200C
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max
Conductor
Diameter
Normal
Overall
Diameter
Max
Weight
Approx.

mm2nos.mmmmmmmmkg/kmAmps???/kmmtrs
84105XX*0.3570.260.80.21.351154.4500
84106XX0.5190.1910.221.671537.1500
84108XX0.75240.211.20.241.991924.7500
Request
Callback
Yes! I am interested
View PDF

Auto 180E-A Wire

Auto 180E-A Wire
  • Auto 180E-A Wire
Ask For Price
Application:
  • Low-tension electric wire for Automobiles
  • Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper E-Cu ETP1 according to DIN 13602, bare conductor
  • Insulation: EBXL ETFE
  • Colour: As per customer order
  • Single core, Single layer insulation

Technical Data:
  • Temperature Range: – 65°C to +180°C (3000 Hours)
  • Test Voltage: 3 kV (r.m.s.) for cables < 0.5 mm2
  • 5 kV (r.m.s.) for cables ≥ 0.5 mm2
  • Standard: DBL 6312
  • VW 60306-1
  • LV 112-1

Features:
  • Flame retardant
  • Highly resistant against acids, Petrol, and diesel.
  • Resistance To hydrolysis
  • Resistance to battery cable
  • Extra flexibility.

Specifications:

Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200C
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max
Conductor
Diameter
Normal
Overall
Diameter
Max.
Weight
Approx.

mm2nos.mmmmmmmmkg/kmAmps???/kmmtrs
84605XX*0.3570.260.80.21.351352500
84606XX0.5190.1910.221.661837.1500
84608XX0.75190.231.20.241.992324.7500
84610XX1190.261.350.242.1112818.5500
Request
Callback
Yes! I am interested
View PDF

Auto 180E-B Cable

Auto 180E-B Cable
  • Auto 180E-B Cable
Ask For Price

Product Details:

Power/Voltage5 kV (r.m.s.)
Length1mm

Application:
  • Low-tension electric wire for Automobiles.
  • Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper E-Cu ETP1 according to DIN EN 13602, bare conductor (also available in multi-stand version)
  • Insulation: FEP (Fluorinated Ethylene propylene) with properties
  • according to ISO 6722-1, Class F
  • Colour: As per customer order
  • Single core

Technical Data:
  • Temperature Range: – 65°C to +210°C (3000 Hours)
  • Test Voltage: 3 kV (r.m.s.) for cables < 0.5 mm2
  • 5 kV (r.m.s.) for cables ≥ 0.5 mm2
  • Standard: LV 112-1
  • VM

Features:
  • Good mechanical and thermal properties
  • Excellent chemical resistance

Specifications:

Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200 C
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max
Conductor
Diameter
Normal
Overall
Diameter
Max
Weight
Approx.

mm2nos.mmmmmmmmkg/kmAmps???/kmmeters
84705XX *0.35120.210.90.21.451452500
84706XX0.5160.2110.221.671837.1500
84708XX0.75240.211.20.241.9102324.7500
84710XX1320.211.350.242122818.5500
Request
Callback
Yes! I am interested
View PDF

Auto 210F- A Wire

Auto 210F- A Wire
  • Auto 210F- A Wire
Ask For Price
Application:
  • Low-tension electric wire for Automobiles.
  • Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper E-Cu ETP1 according to DIN EN 13602, bare conductor (also available in multi-stand version)
  • Insulation: FEP (Fluorinated Ethylene propylene) with properties
  • according to ISO 6722-1, Class F
  • Colour: As per customer order
  • Single core

Technical Data:
  • Temperature Range: – 65°C to +210°C (3000 Hours)
  • Test Voltage: 3 kV (r.m.s.) for cables < 0.5 mm2
  • 5 kV (r.m.s.) for cables ≥ 0.5 mm2
  • Standard: LV 112-1
  • VM

Features:
  • Good mechanical and thermal properties
  • Excellent chemical resistance

Specifications:
Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200C
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor
Diameter
Normal
Overall
Diameter
Max
Weight
Approx

mm2nos.mmmmmmmmkg/kmAmps???/kmmtrs
84805XX*0.3570.260.80.21.341454.4500
84806XX0.5190.1910.221.671937.1500
84808XX0.75190.231.20.241.992524.7500
Request
Callback
Yes! I am interested
View PDF

Auto 210F-B Cable

Auto 210F-B Cable
  • Auto 210F-B Cable
Ask For Price

Product Details:

Power/Voltage5 kV (r.m.s.)
Length0.75mm

Application:
  • Low-tension electric wire for Automobiles.
  • Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.

Product Construction:
  • Conductor: Soft-annealed electrolytic Copper E-Cu ETP1 according to DIN EN 13602, bare conductor (also available in multi-stand version)
  • Insulation: FEP (Fluorinated Ethylene propylene) with properties
  • accoriding to ISO 6722-1, Class F
  • Colour: As per customer order
  • Single core

Technical Data:
  • Temperature Range: – 65°C to +210°C (3000 Hours)
  • Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm2
  • 5kV (r.m.s.) for cables ≥ 0.5 mm2
  • Standard: LV112-1
  • VM 60306-1
  • PSA B25 1110

Features:
  • Good mechanical and thermal properties
  • Excellent chemical resistance

Specifications:

Part
Number
Conductor ConstructionInsulation
Wall Thickness
Normal
CableCurrent
Carrying
Capacity
Max.
Conductor
Resistance
at 200C
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor
Diameter
Normal
Overall
Diameter
Max
Weight
Approx

mm2nos.mmmmmmmmkg/kmAmps???/kmmtrs
84905XX*0.35120.210.90.21.451552500
84906XX0.5160.2110.221.661937.1500
84908XX0.75240.211.20.241.992524.7500
Request
Callback
Yes! I am interested
View PDF
X
Looking for “Standard Cables”?


Reach Us
Arun Kumar (Executive Director)
No. 26/27, Errabalu Chetty Street
Chennai- 600001, Tamil Nadu, India


Call Us

Send E-mail

Send SMS