Welding Cables

Our range of products include 3kv flexible cables rohs, 1 kv flexible cable rohs, sflex fd 820 h 0.75kv flexible cables rohs, sflex fd 820 ch 0.75kv flexible cables rohs, sy cable and flexible cables rohs.

3kV Flexible Cables RoHS

3kV Flexible Cables RoHS
  • 3kV Flexible Cables RoHS
Ask For Price

Product Details:

Power/Voltage3kV
Length22mm

Siechem NSGAFOU 1.8/ 3kV Flexible Cables RoHS

Application:
  • For fixed installation in track bound vehicles
  • In dry locations

Product Construction:
  • Conductor: Fine strands of tinned Copper Wires. Class 5 as per EN 60228
  • Insulation: EBXL – EPR
  • Colour: Light / as per Customer requirement
  • Outer Sheath: EBXL – CPE
  • Colour: Black / as per Customer requirement

Technical Data:
  • Specification: DIN VDE 0207
  • Temperature Range
  • Flexible applications – 250°C to +1200°C
  • Fixed Installation – 400°C to +1200°C
  • Test Voltage: 6 kV
  • Max. Short circuit Temperature: 2800C for 5s.
  • Rated Voltage (U /U): 1.8/3 kV
  • Minimum Bending Radius :
  • Flexible use: 10 X OD
  • Fixed installation: 6 X OD

Features:
  • Excellent Flexibility.
  • Excellent Flame Retardant.
  • Highly Resistive to Oil and Ozone
  • Highly short circuit rated and earth fault resistance cable.
Specifications:
Part Number Conductor sizeOuter Diameter Nom.Conductor resistance at 200C Weight (Approx)

mm2mmΩ/KmKg/Km
64013XX1.55.613.753
64016XX2.56.18.2166
64019XX46.65.0984
64023XX67.23.39107
64027XX108.51.95167
64028XX169.61.24231
64030XX2511.70.795347
64032XX3512.90.565446
64034XX5014.40.393593
64037XX7016.20.277791
Request
Callback
Yes! I am interested

1 kV Flexible Cable RoHS

1 kV Flexible Cable RoHS
  • 1 kV Flexible Cable RoHS
Ask For Price

Product Details:

Power/Voltage1kv
Length19mm

SFLEX SERVO 2YSLCYK-JB  1 kV Flexible Cable RoHS

Application:
  • Interconnection between frequency converter and motor
  • Paper industry
  • Chemical industry
  • Heavy industry

Product Construction:
  • Conductor: Fine Strands of bare copper wires
  • Core Insulation: Polyethylene (PE)
  • Core Twisted concentrically (this is respectively between the gusset in Protective conductors divided into three)
  • Over the Cores aluminum foil
  • Screening braid of tinned copper wires
  • 3+3 Cond version: PVC-outer sheath, black, for outdoor use and direct burial

Technical Data:
  • Temperature Range: – 50C to +700C
  • Fixed installation: – 400C to +700C
  • Rated Voltage (U0/U): 0.6 /1KV
  • Test Voltage: 4000V

Bending Radius:
  • Occasional Flexing: 15 X Outer diameter
  • Fixed installation: 4 X Outer diameter
  • Specification Resistance: 20GΩ X cm

Features:
  • Its low capacity design allows longer cable lengths between the frequency converter and motor.
  • Its low capacity design occurs significant lower level of interference currents
  • In dry, wet and damp interiors
Specifications:
Part NumberNumber of Cores and mm2 Per ConductorOuter Diameter in mm Nom.Max. conductor resistance at 200C Ω /kmWeight Kg/Km approx.
A07913063 X 1.5 + 3G0.25111 3 . 71 6 0
A07916063 X 2.5 + 3G0.512.27 . 9 82 2 0
A07919063 X 4.0 + 3G0.7514.24 . 9 53 2 5
A07923063 X 6.0 + 3G1.015.53 . 3 04 2 5
A07927063 X 10 + 3G1.517.91 . 9 16 2 5
A07928063 X 16 + 3G2.520.21 . 2 18 2 0
A07930063 X 25 + 3G4.023.80.781280
A07932063 X 35 + 3G6.026.90.5541690
A07934063 X 50 + 3G10320.3862400
Request
Callback
Yes! I am interested

SFLEX FD 820 H 0.75kV Flexible Cables RoHS

SFLEX FD 820 H 0.75kV Flexible Cables RoHS
  • SFLEX FD 820 H 0.75kV Flexible Cables RoHS
Ask For Price
Application:
  • Used in damp and wet areas.
  • Used in measuring control and Regulating Circuits.
  • In Power Circuits

Product Construction:
  • Conductor: Finely Stranded Bare Copper Wires
  • Insulation: Halogen Free Compound
  • Nonwoven Wrapping Over Insulation.
  • Inner Sheath: Grey Halogen Free Thermoplastic
  • Braiding: Tinned Copper Wire.
  • Outer Sheath: Silver Grey Halogen Free Thermoplastic
  • Core identification: Black with White Numbers.

Technical Data:

  • Flexible applications: – 250°C to +700°C
  • Fixed Installation: – 400°C to +700°C
  • Testing Voltage: 4 kV
  • Protective Conductor(PC): G- With green/yellow PC X-Without PC
  • Bending Radius(Minimum) :
  • Flexing: 7.5 x Cable Diameter
  • Static: 4 x Cable Diameter
  • Rated Voltage: (U /U) 300/500 V 0
  • 450/750 V
  • Specific Insulation Resistance: 1 T Ohm x cm
  • As per VDE 0281

Features:
  • Medium mechanical Stress.
  • Flexibility
  • Excellent UV Protection.
  • Excellent Flame retardant.

Specifications:

Part NumberNumber of Cores and mm2 Per ConductorOuter Diameter in mm approx.Copper Index Kg/KmWeight Kg/Km approx.
62608022 C x 0 .7 56 .2 61 55 5 .8 3
62608033 C x 0 .7 56 .6 32 26 6 .8 3
6260803G3 G 0 .7 56 .6 32 26 6 .8 3
6260804G4 G 0 .7 57 .2 32 98 1 .8 0
6260805G5 G 0 .7 57 .8 83 79 9 .3 8
6260807G7 G 0 .7 59 .3 85 11 3 9 .4 8
6260812G1 2 G 0 .7 51 1 .0 88 71 7 5 .6 4
6260818G1 8 G 0 .7 51 3 .2 41 3 02 5 8 .5 1
Request
Callback
Yes! I am interested

SFLEX FD 820 CH 0.75kV Flexible Cables RoHS

SFLEX FD 820 CH 0.75kV Flexible Cables RoHS
  • SFLEX FD 820 CH 0.75kV Flexible Cables RoHS
Ask For Price
Application:
  • Used in damp and wet areas.
  • Used in measuring control and Regulating Circuits.
  • In Power Circuits

Product Construction:
  • Conductor: Finely Stranded Bare Copper Wires
  • Insulation: Halogen Free Compound
  • Non woven Wrapping Over Insulation
  • Inner Sheath: Grey Halogen Free Thermoplastic
  • Polyolefin Copolymer Compound
  • Braiding: Tinned Copper Wire
  • Outer Sheath: Silver Grey Halogen Free Thermoplastic
  • Core identification: Black with White Numbers

Technical Data:

  • Flexible applications: – 250C to +700C
  • Fixed Installation: – 400C to +700C
  • Testing Voltage: 4 kV
  • Protective Conductor(PC): G- With green/yellow PC X-Without PC
  • Bending Radius(Minimum) :
  • Flexing: 7.5 x Cable Diameter
  • Static: 4 x Cable Diameter
  • Rated Voltage: (U /U) 300/500 V 0 450/750 V
  • Specific Insulation Resistance: 1 T Ohm x cm
  • As per VDE 0281

Features:
  • Medium mechanical Stress.
  • Flexibility
  • Excellent UV Protection.
  • Excellent Flame retardant.

Specifications:
Part NumberNumber of Cores and mm2 Per ConductorOuter Diameter in mm approx.Copper Index Kg/KmWeight Kg/Km approx.
62708022 C x 0 .7 57 .2 33 9 .0 01 1 8 .7 9
62708033 C x 0 .7 57 .6 04 8 .0 01 3 4 .1 7
6270803G3 G 0 .7 57 .6 04 8 .0 01 3 4 .1 7
6270804G4 G 0 .7 58 .2 15 9 .0 01 5 7 .1 2
6270805G5 G 0 .7 58 .8 76 9 .0 01 8 1 .0 9
6270807G7 G 0 .7 59 .5 79 0 .0 02 1 6 .8 5
6270812G1 2 G 0 .7 51 1 .7 81 2 9 .0 03 2 7 .7 4
Request
Callback
Yes! I am interested

SY Cable

SY Cable
  • SY Cable
Ask For Price

Product Details:

Power/Voltage1500V
Length22.8 mm

Application:
  • Suited for use in Control units, production lines, communication systems, conveyor belts, ship building.
  • Used for fixed or mobile installation in dry, damp or wet areas.

Product Construction:
  • Conductor: Fine wire stranded, plain copper conductor
  • Insulation: PVC
  • Screening: Tinned Steel-wire braided
  • Outer Sheath: PVC

Technical Data:
  • Temperature Range: -40°C to +120°C
  • Rated Voltage (U°/U): 60 V
  • Test Voltage: 1500 V

Features:
  • Flame retardant
  • Smoke density
  • Gases corrosivity
  • Gases toxicity
  • Electro magnetic interference resistance.

Specifications:

Part NumberNumber of Cores and mm2
Per Conductor
Outer Diameter in
mm approx.
Copper Index
Kg/Km
Total Weight
Kg/Km approx.
339 23 XX1C X 68.551139
339 27 XX1C X 1010.485212
339 28 XX1C X 1611.9132290
339 30 XX1C X 2513.6207403
339 32 XX1C X 3515289516
339 34 XX1C X 5018413731
339 37 XX1 x 7021579996
339 38 XX1 x 9522.87851250
Request
Callback
Yes! I am interested

Flexible Cables RoHS

Flexible Cables RoHS
  • Flexible Cables RoHS
Ask For Price

Product Details:

Power/Voltage500V
Length6mm

NSSHOU 1kV EBXL Flexible Cables RoHS
Application:
  • Moving equipment and machinery.
  • Dry and damp interiors.
  • Underground mining as well as in Surface
  • mining
  • Fixed installations and building sites.
  • Robots and handling units
  • Electricity transferring units where constant
  • mobility is needed.
  • Used at high mechanical stress.
  • Suitable for industry under extreme environmental
  • conditions.
  • Outdoor uses.

Product Construction:
  • Conductor: Finely Stranded tinned Copper Wires
  • Insulation: Electron Beam Cross Linked Polyolefin.
  • Cores – Twisted.
  • Inner Sheath: Electron Beam Cross Linked Polyolefin.
  • Outer Sheath: Electron Beam Cross Linked Polyolefin(Yellow) or as per customer order

Technical Data:
  • Temperature Range:
  • Flexible applications: – 250C to +1250C
  • Fixed Installation: – 400C to +1250C
  • Test Voltage: 3 kV
  • Protective Conductor(PC): G- With green/yellow PC
  • X -Without PC
  • Bending Radius(Minimum):
  • Flexing: 10 x Cable Diameter
  • Static: 5 x Cable Diameter
  • Rated Voltage (U /U): 600/1000 V
  • Specific Insulation Resistance: >1 G Ohm x cm

Features:
  • Electron Beam Cross Linked
  • High damage resistant
  • Ozone resistant.
  • Resistant against oil, fat and chemicals
  • High insulation resistant.
  • Low abrasion.
  • Single core cables are used in welding equipments.
  • High notch resistance.

Specifications:

Part NumberNumber of Cores and mm2 Per ConductorOuter Diameter in mm approx.Copper Index Kg/KmWeight Kg/Km approx.
6391303G3G 1 .510.9243173.14
6391304G4 G 1 .511.858208.26
6391305G5 G 1 .512.7572246.25
6391603G3 G 2 .512.7572246.6
6391604G4 G 2 .513.896297.9
6391605G5 G 2 .514.94120354.66
6391607G7 G 2 .516.15168435.89
6391612G1 2 G 2 .520.85288732.52
Request
Callback
Yes! I am interested

100 V Welding Cable RoHS

100 V Welding Cable RoHS
  • 100 V Welding Cable RoHS
Ask For Price

Product Details:

BrandSiechem
ModelH01N2-D

H01N2-D 100 V Welding Cable RoHS

Application:
  • For transmission high currents from the electric welding device to the welding tool
  • On assembly lines and conveyor systems

Product Construction:
  • Conductor: Annealed Copper conductor, Class 6 flexible cable as per EN 60228
  • Optional: Tinned copper
  • Separator: Dry Paper, Polyester Tape
  • Sheath: Covering in two layers – Outer Layer EM5 Conforms to EN 50363-2-2 Inner layer EM5 or EI7 Conforms to EN 50363-1
  • Color: Orange or Black

Technical Data:
  • Temperature Range: 85°C
  • Rated Voltage: 100/100 V
  • Bending Radius(Minimum): 10 x Overall dia.
  • Type: HO1N2-D
  • Specification: BS EN 50525-2-81 BS 638-4
  • Conductor resistance: EN 60228

Features:
  • Oil resistant
  • Extra flexible
  • Heat resistant
  • Medium mechanical stress

Specifications:

Part NumberSizeConductor diameterStand dia Max.Thickness of coveringOverall diameterMaximum conductor resistance 20°C Ω/kmWeight approx.
MinimumMaximumTinned
Wires
Plain
Wires

mm2mmmmmmmmmmΩ/kmΩ/kmKg/Km
A05427XX105.10.2127.79.71.951.91149
A05428XX166.30.2128.8111.241.21207
A05430XX257.80.21210.112.70.7950.78291