Product Details:
Brand | Siechem |
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A81306XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 18 | 37.1 | 1000 |
A81308XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 23 | 24.7 | 1000 |
A81310XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 28 | 18.5 | 1000 |
A81313XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 35 | 12.7 | 1000 |
A81314XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 42 | 9.42 | 1000 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | PE-X |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class C |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84305XX * | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 12 | 54.4 | 500 |
84306XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
84308XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 20 | 24.7 | 500 |
84310XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 24 | 18.5 | 500 |
84313XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40C to +125C |
Standard | SAEJ 1939/15 |
Test Voltage | 1 kV |
Test Method | SAEJ1128 |
Characteristic Impedance | 120 +/- 12 ohm |
Specific Resistance | 50mohm/m(Max) |
Specific Capacitance | 40 pF/m |
Cable Bending Radius | 4 X Cable Dia |
Part Number | Conductor Construction | Nominal Insulation Thickness | Core Diameter | Sheath Thickness Nominal | Cable Diameter | |||||
Nominal Cross Section | No.of Strands | Strand Diameter Max. | Conductor Diameter Nom. | Min | max | Min | Max | |||
Sq.mm/AWG | Nos | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 Sq.mm | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 Sq.mm | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Brand | Siechem |
Country of Origin | Made in India |
Conductor | E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked Polyethylene |
No. of Cores | Single core |
Temperature Range | - 40 to +120 Degree C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81406XX* | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.2 | 8 | 36.7 | 16 | 1000 |
81408XX | 0.75 | 30 | 0.18 | 1.1 | 0.5 | 2.2 | 2.4 | 11 | 24.4 | 20 | 1000 |
81412XX | 1.25 | 50 | 0.18 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.7 | 28 | 1000 |
Product Details:
Brand | Siechem |
Number Of Cores | Single Core |
Country of Origin | Made in India |
Insulation | PVC,Lead-free |
Conductor Material | Copper |
Temperature Range | - 40 to +80 Degree C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
80404XX* | 0.3 | 15 | 0.18 | 0.8 | 0.5 | 1.8 | 1.9 | 7 | 48.9 | 10 | 1000 |
80406XX | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.1 | 9 | 36.7 | 12 | 1000 |
80408XX | 0.75 | 30 | 0.18 | 1.2 | 0.5 | 2.2 | 2.3 | 12 | 24.4 | 15 | 1000 |
80412XX | 1.25 | 50 | 0.18 | 1.5 | 0.5 | 2.5 | 2.6 | 17 | 14.7 | 20 | 1000 |
Product Details:
Conductor | Copper |
Insulation | PVC |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +105 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Sheath Thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
85419XX* | 4 | 56 | 0.31 | 2.75 | 0.8 | 2 | 8.4 | 123 | 61 | 4.71 | 500 | |
85423XX | 6 | 84 | 0.31 | 3.3 | 0.8 | 2 | 9 | 149 | 77 | 3.1 | 500 | |
85427XX | 10 | 80 | 0.41 | 4.5 | 1 | 3 | 12.8 | 267 | 263 | 1.82 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40C to +150C |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class D |
Conductor | Soft-annealed electrolytic Copper Cu - ETP1 |
Insulation | TPE- E (Thermoplastic Polyester Elastomer) |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A89302XX* | 0.22 | 7 | 0.2 | 0.6 | 0.2 | 1.2 | 3 | 10 | 84.8 | 500 |
A89305XX | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A89306XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 14 | 37.1 | 500 |
A89308XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 18 | 24.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3kV |
Standard | ISO 6722, Class C |
Conductor | Copper E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked EVA (Ethylene Vinyl Acetate) |
Siechem is India’s No.1 manufacturer & exporter of Automotive Wires & Cables. We manufacture almost all the types of automotive wires & cables that meet Japanese, Korean, American and European OEM specification. Some of the details are listed below :
JIS C 3406, JASO D 611, JASO D 608, ISO 6722, IS 2465, SAE J 1128, SAE J 1127, SAE J 1678, SAE J 1939/15 Volvo, Ford ES –AU5T -1A348, ES 91110-05, YPES-17-21-005, YPES-17-21-004, DIN 72551-6 & customized to your specification.
Types of Cable: AV, AV-f, AVS, AVS-f, AVSS, AVSS-f, AVSSH-f, AVSSX, AVSSX-f, AVX, AVX-f, AEX, AEX-f, AESSX, AESSX-f, CPE-FR, CPE –FR TW, EB, HEB, HDEB, GPT, HDT, TWP, TXL, GXL, SXL, STT, SGT, STX, SGX, WTA, WXC, RK, SK, RXKB, SXKB, R2, R4, Auto 85, Auto 85-TW, Auto 85-UTW, Auto 100, Auto 100 TW, Auto UTW, Auto 125, Auto 125-TW, Auto 125-UTW, Auto 150, Auto 150-TW, Auto 150-UTW, Auto 175, Auto 175-TW, Auto 175-UTW, ACW 150, Auto 125 P, Auto 125X-A & B, Auto 150 A-A & A-B, Auto 180 E-A & E-B, Auto 200G, Auto 200G AL, Auto 210F-A & B, Auto 260T, Auto 260 R-A & R-B, FLY, FLYW, FLYK, FLRYK, FLYWK, FLRYWK, FLRYW-A & B, FLRY T2 IR, FRLY T3 IR, FLR4Y-A & B, FL91Y-FL11Y, FLYY, FLRY-A,B&H, FLYOY-FLYKOY, FLRYDY, FLR4G11Y-FL4G11Y, FLR2X11Y, FLR31Y11Y, FLRY11Y, FLALRY, FLALRYW, FLR6Y-B, FLR12Y-A, ABS Sensor & CAN BUS UTP.
Product Details:
Insulation | EBXL- CPE- FR |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +125 deg C |
Standards | ISO 6722 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
A82602XX* | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 84.8 | 9 | 500 |
A82605XX | 0.35 | 7 | 0.26 | 0.9 | 0.2 | 1.4 | 5 | 54.5 | 12 | 500 |
A82606XX | 0.5 | 19 | 0.19 | 1.1 | 0.22 | 1.6 | 6 | 37.1 | 15 | 500 |
A82608XX | 0.75 | 19 | 0.23 | 1.3 | 0.24 | 1.9 | 9 | 24.7 | 20 | 500 |
Product Details:
Conductor | Copper |
Insulation | Plasticized PVC |
No. of Cores | Single core |
Temperature Range | - 50 deg C to +105 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722,Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | meter | |
83506XX* | 0.5 | 28 | 0.16 | 1.1 | 0.6 | 2.3 | 11 | 15 | 37.7 | 500 |
83508XX | 0.75 | 42 | 0.16 | 1.3 | 0.6 | 2.5 | 14 | 19 | 25.1 | 500 |
83510XX | 1 | 57 | 0.16 | 1.5 | 0.6 | 2.7 | 17 | 23 | 18.8 | 500 |
83513XX | 4.5 | 84 | 0.16 | 1.8 | 0.6 | 3 | 23 | 29 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 90 deg C to +260 deg C |
Number of Cores | Single |
Standard | ISO 6722, Class H |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PTFE ( Polytetrafluoroethylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
A87405XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.35 | 5 | 12 | 87.9 | 500 | |
A87406XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 17 | 56.8 | 500 | |
A87408XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 22 | 38.6 | 500 | |
A87410XX | 1 | 32 | 0.21 | 1.4 | 0.24 | 1.95 | 11 | 27 | 25.7 | 500 |
Product Details:
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Max. Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81206XX* | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.2 | 9 | 36.7 | 14 | 1000 |
81208XX | 0.75 | 30 | 0.18 | 1.1 | 0.5 | 2.2 | 2.4 | 11 | 24.4 | 18 | 1000 |
81212XX | 1.25 | 50 | 0.18 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.7 | 25 | 1000 |
Product Details:
Brand | Siechem |
Number Of Cores | Single Core |
I Deal In | New Only |
Temperature Range | - 40 to +85 Degree C |
Country of Origin | Made in India |
Conductor Material | Copper |
Insulation Material | PVC |
Voltage Rating | 60 Volts |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current carrying capacity | Standard Length* | |||
Size | No. of Strands | Diameter of Single wire max. | Overall Diameter Max | Weight Approx | ||||
mm2 | nos. | mm | mm | mm | kg/km | Amps | mtrs | |
A88106XX* | 0.5 | 7 | 0.31 | 0.91 | 3.1 | 14 | 14 | 500 |
A88160XX | 0.8 | 16 | 0.26 | 0.94 | 3.4 | 20 | 18 | 500 |
A88110XX | 1 | 19 | 0.29 | 1.02 | 3.7 | 25 | 24 | 500 |
A88111XX | 2 | 19 | 0.36 | 1.04 | 4.2 | 33 | 32 | 500 |
A88117XX | 3 | 19 | 0.45 | 1.17 | 5.1 | 49 | 43 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 to +85 Degree C |
Standard | SAE J1128 |
Country of Origin | Made in India |
Insulation | PVC |
No. of Cores | Single core |
Test Voltage | 1 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current carrying capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Diameter of Single wire max | Overall Diameter Max | Weight Approx. | ||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | mtrs | |
85102XX* | 0.22 | 7 | 0.21 | 0.63 | 0.4 | 1.5 | 5 | 7 | 500 |
85105XX | 0.35 | 7 | 0.26 | 0.78 | 0.4 | 1.7 | 6 | 9 | 500 |
85106XX | 0.5 | 7 | 0.31 | 0.93 | 0.4 | 1.9 | 8 | 12 | 500 |
85160XX | 0.8 | 16 | 0.26 | 1.21 | 0.4 | 2.2 | 10 | 17 | 500 |
85110XX | 1 | 19 | 0.29 | 1.45 | 0.4 | 2.4 | 13 | 22 | 500 |
Product Details:
Brand | Siechem |
Number Of Cores | Single |
Standard | Volvo type |
No. of Cores | 1 |
Temperature Range | - 40 to +70 deg C |
Rated voltage two-coloured | 100 V |
Wire length | 500 Meter |
Part Number |
Conductor Construction | Insulation Wall Thickness Normal |
Cable | Max. Conductor Resistance at 200C |
Current Carrying Capacity |
Standard Length* |
||||
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Normal |
Overall Diameter Max. |
Weight Approx |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
86806XX* | 0.5 | 16 | 0.21 | 1.1 | 0.6 | 2.6 | 9 | 39 | 8 | 500 |
86808XX | 0.75 | 24 | 0.21 | 1.3 | 0.6 | 2.8 | 11 | 26 | 10 | 500 |
86810XX | 1 | 32 | 0.21 | 1.5 | 0.6 | 3 | 13 | 19.5 | 12 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC Compound |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A82406XX** | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 11 | 37.1 | 500 |
A82408XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 14 | 24.7 | 500 |
A82410XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 17 | 18.5 | 500 |
A82413XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 14 | 22 | 12.7 | 500 |
A82414XX | 2 | 19 | 0.38 | 2 | 0.25 | 2.4 | 20 | 27 | 9.42 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +125 deg C (3000 Hours) |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722, ClassC |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PE-X with properties according to ISO 6722 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84202XX* | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 9 | 84.8 | 500 |
84205XX | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
84206XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 15 | 37.1 | 500 |
84208XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 20 | 24.7 | 500 |
84210XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 24 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +150 deg C |
Voltage | 60 V |
Conductor | Copper |
Insulation | EBXL |
No. of Cores | 1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Max. Conductor Resistance at 200C | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84105XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
84106XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 15 | 37.1 | 500 |
84108XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Number Of Core | Single |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max | Conductor Diameter Max | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A84105XX* | 0.35 | 7 | 0.27 | 0.9 | 0.3 | 1.3 | 5 | 13 | 54.4 | 2000 |
A84106XX | 0.5 | 19 | 0.19 | 1.1 | 0.3 | 1.6 | 6 | 18 | 37.1 | 2000 |
A84108XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 23 | 24.7 | 2000 |
A84110XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 28 | 18.5 | 2000 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Temperature Range | - 40 deg C to +125 deg C |
No. of Cores | 1 |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | No. of Strands | Conductor Diameter max. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A81506XX* * | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.4 | 6 | 16 | 37.1 | 500 |
A81508XX | 0.75 | 19 | 0.24 | 1.3 | 0.35 | 1.6 | 8 | 20 | 24.7 | 500 |
A81510XX | 1 | 19 | 0.27 | 1.5 | 0.35 | 1.75 | 10 | 24 | 18.5 | 500 |
A81513XX | 1.5 | 19 | 0.33 | 1.8 | 0.35 | 2.1 | 15 | 32 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 90 deg C to +260 deg C |
Number of Cores | Single |
Standard | ISO 6722, Class H |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PTFE ( Polytetrafluoroethylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
A87302XX * | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 12 | 87.9 | 500 | |
A87305XX | 0.35 | 7 | 0.27 | 0.8 | 0.2 | 1.35 | 5 | 15 | 56.8 | 500 | |
A87306XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 21 | 38.6 | 500 |
Product Details:
Temperature Range | - 65 deg C to +210 deg C |
Brand | Siechem |
Conductor | Soft-annealed electrolytic Copper |
Insulation | FEP |
No. of Cores | 1 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84905XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 15 | 52 | 500 |
84906XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 19 | 37.1 | 500 |
84908XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84910XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84913XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 65 deg C to +210 deg C |
No. Of Core | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | LV 112-1 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | FEP (Fluorinated Ethylene propylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
84805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 4 | 14 | 54.4 | 500 |
84806XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 19 | 37.1 | 500 |
84808XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84810XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84813XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 80 deg C to +200 deg C |
Conductor | Copper |
Insulation | Silicon Rubber |
Standard | ISO 6722 , Class F |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87127XX* | 10 | 50 | 0.52 | 4.5 | 0.8 | 6.5 | 55 | 105 | 3.03 | 500 |
A87128XX | 16 | 78 | 0.52 | 5.8 | 0.8 | 8.3 | 76 | 141 | 1.93 | 500 |
A87130XX | 25 | 122 | 0.52 | 7.2 | 1.04 | 10.4 | 117 | 184 | 1.24 | 500 |
A87132XX | 35 | 172 | 0.52 | 8.5 | 1.04 | 11.6 | 152 | 226 | 0.878 | 500 |
A87134XX | 50 | 247 | 0.52 | 10.5 | 1.2 | 13.5 | 213 | 287 | 0.613 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 80 deg C to +200 deg C |
No. Of Core | Single |
Standard | ISO 6722 , Class F |
Test Voltage | 3 kV |
Conductor | Copper |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87005XX * | 0.35 | 12 | 0.21 | 0.9 | 0.5 | 2 | 7 | 16 | 54.4 | 500 |
A87006XX | 0.5 | 16 | 0.21 | 1 | 0.6 | 2.3 | 10 | 21 | 37.1 | 500 |
A87008XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 26 | 24.7 | 500 |
A87010XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 31 | 18.5 | 500 |
A87013XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3.1 | 21 | 40 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | 65 deg C to +180 deg C (3000 Hours) |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg /km | mtrs | |
84605XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 13 | 52 | 500 |
84606XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 18 | 37.1 | 500 |
84608XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 23 | 24.7 | 500 |
84610XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 28 | 18.5 | 500 |
84613XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 36 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 40 deg C to +150 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722,Class D |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | TPE-E |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84405XX* | 0.35 | 7 | 0.26 | 0.8 | 0.35 | 1.3 | 5 | 12 | 52 | 500 |
84406XX | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.6 | 6 | 16 | 37.1 | 500 |
84408XX | 0.75 | 19 | 0.23 | 1.2 | 0.35 | 1.9 | 9 | 22 | 24.1 | 500 |
84410XX | 1 | 19 | 0.26 | 1.35 | 0.35 | 2.1 | 11 | 26 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | -40 deg C to +105 deg C |
No. Of Core | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | PSA STE 9641879499 IR |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.4 | 5 | 10 | 55.9 | 500 |
83806XX | 0.5 | 16 | 0.21 | 1 | 0.28 | 1.7 | 7 | 14 | 37.1 | 500 |
83808XX | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 1.9 | 10 | 17 | 24.7 | 500 |
83810XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.15 | 12 | 21 | 19.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 50 deg C to +125 deg C |
No. Of Core | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Soft PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87505XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A87506XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
A87508XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
A87510XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 23 | 18.5 | 500 |
A87513XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 16 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 40 deg C to +105 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | PSA STE 96 41879499 IR |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Plasticized PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.4 | 5 | 11 | 55.9 | 500 |
83806XX | 0.5 | 16 | 0.21 | 1 | 0.28 | 1.7 | 6 | 15 | 37.1 | 500 |
83808XX | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 1.9 | 9 | 19 | 24.1 | 500 |
83810XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.15 | 12 | 23 | 19.5 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +105 deg C |
Standard | DIN 72551 - 6 |
Test Voltage | 3kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | ||||||
Bare | Tinned | ||||||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | ???/km | Amps | mtrs | |
81805XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 52 | 54.5 | 11 | 500 |
81806XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 37.1 | 38.2 | 13 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +105 deg C |
Standard | DIN 72551 - 6 |
Test Voltage | 3kV (r.m.s.) for cables |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Max. | Overall Diameter Max. | Weight Approx | ||||||
Bare | Tinned | ||||||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | ???/km | Amps | mtrs | |
81702XX * | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 84.8 | 86.5 | 8 | 500 |
81705XX | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.3 | 5 | 52 | 54.5 | 10 | 500 |
81706XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 37.1 | 38.2 | 13 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +125 deg C |
Number of Cores | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class C |
Outer Sheath | TPE-U |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath Thickness | Cable | Conductor Resistance at 200 C | Standard Length* | ||||||
Nominal Cross- Section | No. of Core | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | Bare | Tinned | ||||
mm2 | mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | ???/km | mtrs | |
8570502* | 0.35 | 2 | 12 | 0.21 | 0.9 | 0.25 | 0.5 | 3.9 | 25 | 52 | 54.5 | 500 |
8570602 | 0.5 | 2 | 19 | 0.19 | 1 | 0.3 | 0.65 | 4.6 | 35 | 37.1 | 40.1 | 500 |
8570602 | 0.5 | 2 | 28 | 0.16 | 1 | 0.3 | 0.65 | 4.6 | 36 | 37.1 | 40.1 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 950C to +210C (3000 Hours) |
Number of Cores | Single core |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | LV 112-1 |
Wire Code | FLR6Y-B |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A89505XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 15 | 52 | 500 |
A89506XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 7 | 19 | 37.1 | 500 |
A89508XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 10 | 25 | 24.7 | 500 |
A89510XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
A89513XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 18 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Conductor | Aluminium 99.7 % 1.25mm2 |
Insulation | Soft -PVC With properties according |
Test Voltage | 3kV (r.m.s.) |
Standard | ISO 6722,Class C |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87908XX* | 0.75 | 11 | 0.3 | 1.3 | 0.24 | 1.9 | 4 | 15 | 43.6 | 500 |
A87910XX | 1 | 16 | 0.29 | 1.5 | 0.24 | 2.1 | 5 | 18 | 32.7 | 500 |
A87912XX | 1.25 | 16 | 0.32 | 1.7 | 0.24 | 2.3 | 6 | 21 | 24.8 | 500 |
A87913XX | 1.5 | 16 | 0.35 | 1.8 | 0.24 | 2.4 | 7 | 23 | 21.2 | 500 |
A87914XX | 2 | 15 | 0.42 | 2 | 0.28 | 2.8 | 9 | 28 | 15.7 | 500 |
Product Details:
Brand | Siechem |
Insulation | Class 2 |
No. of Cores | 1 |
Rated Voltage | 100 V |
Standard | Volvo type |
Temperature Range | - 40 deg C to +100 deg C |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86505XX* | 0.35 | 12 | 0.21 | 0.9 | 0.3 | 1.5 | 6 | 54.4 | 5 | 100 |
86506XX | 0.5 | 16 | 0.21 | 1.1 | 0.35 | 1.9 | 8 | 39 | 8 | 100 |
86508XX | 0.75 | 24 | 0.21 | 1.3 | 0.35 | 2.1 | 10 | 26 | 10 | 100 |
86510XX | 1 | 32 | 0.21 | 1.5 | 0.35 | 2.3 | 12 | 19.5 | 12 | 100 |
86513XX | 1.5 | 30 | 0.26 | 1.8 | 0.35 | 2.6 | 17 | 13.3 | 16 | 100 |
Product Details:
Number of Core | 1 Core |
Type | EB |
Conductor | Soft / annealed Plain Copper |
Insulation | PVC,Lead-free |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
83121XX* | 5 | 7/9/0.32 | 0.32 | 3.1 | 0.6 | 4.3 | 4.7 | 57 | 3.71 | 50 | 500 |
83126XX | 9 | 7/16/0.32 | 0.32 | 4.2 | 0.6 | 5.4 | 5.8 | 94 | 2.09 | 72 | 500 |
83127XX | 10 | 19/6/0.32 | 0.32 | 4.2 | 0.6 | 5.5 | 5.9 | 96 | 2.05 | 72 | 500 |
83155XX | 15 | 19/9/0.32 | 0.32 | 5.3 | 0.6 | 6.5 | 6.9 | 140 | 1.37 | 94 | 500 |
Product Details:
Brand | Siechem |
Insulation | Class 4 |
No. of Cores | Single core |
Rated Voltage | 50 VDC |
Standard | Volvo type |
Temperature Range | - 40 deg C to +150 deg C |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | . Conductor Resistance at 200C | StaC-Max Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86605XX* | 0.35 | 7 | 0.26 | 0.78 | 0.2 | 1.4 | 4.5 | 54.4 | 5 | 500 |
86606XX | 0.5 | 19 | 0.19 | 0.95 | 0.22 | 1.6 | 6 | 37.1 | 8 | 500 |
86608XX | 0.75 | 19 | 0.23 | 0.95 | 0.24 | 1.9 | 9.4 | 24.7 | 10 | 500 |
86610XX | 1 | 32 | 0.2 | 1.5 | 0.24 | 2.1 | 12 | 18.5 | 12 | 500 |
86613XX | 1.5 | 37 | 0.22 | 1.54 | 0.24 | 2.4 | 16 | 12.7 | 16 | 500 |
Product Details:
No. of Core | Single |
Insulation | PVC, Lead-free |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Color | Black |
Conductor Material | E- Cu ETP1 |
Other Details:
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82461XX* | 13 | 133 | 0.36 | 4.83 | 1.09 | 7.8 | 141 | 1.4 | 93 | 500 |
82462XX | 19 | 133 | 0.46 | 6.09 | 1.12 | 9.5 | 205 | 0.94 | 119 | 500 |
82463XX | 32 | 133 | 0.57 | 7.67 | 1.12 | 11 | 332 | 0.56 | 161 | 500 |
82458XX | 40 | 259 | 0.46 | 8.49 | 1.12 | 12 | 407 | 0.42 | 190 | 500 |
82434XX | 50 | 1026 | 0.26 | 9.47 | 1.12 | 13 | 511 | 0.36 | 211 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
A81206XX* | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 37.1 | 14 | 500 |
A81208XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 1.6 | 8 | 24.7 | 18 | 500 |
A81210XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 18.5 | 22 | 500 |
A81213XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 15 | 12.7 | 29 | 500 |