Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC |
Temperature Range | - 40 deg C to +100 deg C |
Standard | ISO 6722 Class B |
Test Voltage | 3 kV |
No. of Cores | Single core |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 20 C | Standard Length* | |||||
Nominal CrossSection | No. of Strands | ||||||||||
2mm | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
*A83205XX | 0.35 | 7 | 0.27 | 0.9 | 0.25 | 1.4 | 5 | 10 | 54.4 | 2000 | |
A83206XX | 0.5 | 19 | 0.19 | 1.1 | 0.28 | 1.6 | 6 | 13 | 37.1 | 2000 | |
A83208XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 17 | 24.7 | 2000 | |
A83210XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 20 | 18.5 | 2000 | |
A83213XX | 1.5 | 19 | 0.33 | 1.8 | 0.3 | 2.4 | 17 | 26 | 12.7 | 2000 |
Product Details:
Brand | Siechem |
Number Of Cores | Single Core |
Country of Origin | Made in India |
Insulation | PVC,Lead-free |
Conductor Material | Copper |
Temperature Range | - 40 to +80 Degree C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
80404XX* | 0.3 | 15 | 0.18 | 0.8 | 0.5 | 1.8 | 1.9 | 7 | 48.9 | 10 | 1000 |
80406XX | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.1 | 9 | 36.7 | 12 | 1000 |
80408XX | 0.75 | 30 | 0.18 | 1.2 | 0.5 | 2.2 | 2.3 | 12 | 24.4 | 15 | 1000 |
80412XX | 1.25 | 50 | 0.18 | 1.5 | 0.5 | 2.5 | 2.6 | 17 | 14.7 | 20 | 1000 |
Product Details:
Brand | Siechem |
Country of Origin | Made in India |
Conductor | E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked Polyethylene |
No. of Cores | Single core |
Temperature Range | - 40 to +120 Degree C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81406XX* | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.2 | 8 | 36.7 | 16 | 1000 |
81408XX | 0.75 | 30 | 0.18 | 1.1 | 0.5 | 2.2 | 2.4 | 11 | 24.4 | 20 | 1000 |
81412XX | 1.25 | 50 | 0.18 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.7 | 28 | 1000 |
Product Details:
Insulation | PVC |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81006XX* | 0.5 | 19 | 0.19 | 1 | 0.3 | 1.4 | 1.5 | 6 | 34.6 | 13 | 1000 |
81008XX | 0.75 | 19 | 0.23 | 1.2 | 0.3 | 1.6 | 1.7 | 9 | 23.6 | 16 | 1000 |
81012XX | 1.25 | 37 | 0.21 | 1.5 | 0.3 | 1.8 | 1.9 | 14 | 14.6 | 22 | 1000 |
Product Details:
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Max. Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81206XX* | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.2 | 9 | 36.7 | 14 | 1000 |
81208XX | 0.75 | 30 | 0.18 | 1.1 | 0.5 | 2.2 | 2.4 | 11 | 24.4 | 18 | 1000 |
81212XX | 1.25 | 50 | 0.18 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.7 | 25 | 1000 |
Product Details:
Conductor | Copper |
Insulation | PVC |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611-94 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Numbe | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Weight Approx. | |||||||
Nom | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
80604XX* | 0.3 | 19 | 0.16 | 0.8 | 0.3 | 1.4 | 1.5 | 5 | 48.8 | 9 | 1000 |
80606XX | 0.5 | 19 | 0.19 | 1 | 0.3 | 1.6 | 1.7 | 7 | 34.6 | 11 | 1000 |
80608XX | 0.75 | 19 | 0.23 | 1.2 | 0.3 | 1.8 | 1.9 | 9 | 23.6 | 14 | 1000 |
80612XX | 1.25 | 37 | 0.21 | 1.5 | 0.3 | 2.1 | 2.2 | 14 | 14.6 | 19 | 1000 |
Product Details:
Conductor | Copper |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81106XX* | 0.5 | 7 | 0.32 | 1 | 0.5 | 2 | 2.2 | 9 | 32.7 | 15 | 1000 |
81154XX | 0.85 | 11 | 0.32 | 1.2 | 0.5 | 2.2 | 2.4 | 12 | 20.8 | 19 | 1000 |
81112XX | 1.25 | 16 | 0.32 | 1.5 | 0.6 | 2.7 | 2.9 | 17 | 14.3 | 25 | 1000 |
Product Details:
Conductor | Copper |
Insulation | PVC,Lead-free |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
80904XX* | 0.3 | 7 | 0.26 | 0.8 | 0.3 | 1.4 | 1.5 | 5 | 50.2 | 10 | 1000 |
80906XX | 0.5 | 7 | 0.32 | 1 | 0.3 | 1.6 | 1.7 | 7 | 32.7 | 14 | 1000 |
80954XX | 0.85 | 19 | 0.24 | 1.2 | 0.3 | 1.8 | 1.9 | 10 | 21.7 | 18 | 1000 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 to +120 Degree C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81554XX* | 0.85 | 19 | 0.24 | 1.21 | 0.3 | 1.9 | 10 | 21.7 | 20 | 1000 |
81514XX | 2 | 37 | 0.26 | 1.83 | 0.4 | 2.7 | 22 | 9.5 | 35 | 500 |
Product Details:
Brand | Siechem |
Insulation | Class 4 |
No. of Cores | Single core |
Rated Voltage | 50 VDC |
Standard | Volvo type |
Temperature Range | - 40 deg C to +150 deg C |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | . Conductor Resistance at 200C | StaC-Max Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86605XX* | 0.35 | 7 | 0.26 | 0.78 | 0.2 | 1.4 | 4.5 | 54.4 | 5 | 500 |
86606XX | 0.5 | 19 | 0.19 | 0.95 | 0.22 | 1.6 | 6 | 37.1 | 8 | 500 |
86608XX | 0.75 | 19 | 0.23 | 0.95 | 0.24 | 1.9 | 9.4 | 24.7 | 10 | 500 |
86610XX | 1 | 32 | 0.2 | 1.5 | 0.24 | 2.1 | 12 | 18.5 | 12 | 500 |
86613XX | 1.5 | 37 | 0.22 | 1.54 | 0.24 | 2.4 | 16 | 12.7 | 16 | 500 |
Product Details:
Brand | Siechem |
Insulation | Class 2 |
No. of Cores | 1 |
Rated Voltage | 100 V |
Standard | Volvo type |
Temperature Range | - 40 deg C to +100 deg C |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86505XX* | 0.35 | 12 | 0.21 | 0.9 | 0.3 | 1.5 | 6 | 54.4 | 5 | 100 |
86506XX | 0.5 | 16 | 0.21 | 1.1 | 0.35 | 1.9 | 8 | 39 | 8 | 100 |
86508XX | 0.75 | 24 | 0.21 | 1.3 | 0.35 | 2.1 | 10 | 26 | 10 | 100 |
86510XX | 1 | 32 | 0.21 | 1.5 | 0.35 | 2.3 | 12 | 19.5 | 12 | 100 |
86513XX | 1.5 | 30 | 0.26 | 1.8 | 0.35 | 2.6 | 17 | 13.3 | 16 | 100 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Conductor | Soft-annealed electrolytic Copper E- Cu ETP1 |
Insulation | PVC, Lead-free |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82561XX* | 13 | 133 | 0.36 | 4.83 | 1.52 | 8.6 | 166 | 1.4 | 93 | 500 |
82562XX | 19 | 133 | 0.46 | 6.09 | 1.65 | 10.5 | 257 | 0.94 | 119 | 500 |
82563XX | 32 | 133 | 0.57 | 7.67 | 1.65 | 12 | 373 | 0.56 | 161 | 500 |
82558XX | 40 | 259 | 0.46 | 8.49 | 1.65 | 13 | 455 | 0.42 | 190 | 500 |
82534XX | 50 | 1026 | 0.26 | 9.47 | 1.65 | 14.5 | 545 | 0.36 | 215 | 500 |
Product Details:
Number of Core | 1 Core |
Conductor | Soft / annealed Plain Copper |
Insulation | PVC |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82261XX* | 13 | 133 | 0.36 | 4.83 | 1.09 | 7.8 | 147 | 1.4 | 126 | 500 |
82262XX | 19 | 133 | 0.46 | 6.09 | 1.12 | 9.5 | 230 | 0.94 | 161 | 500 |
82263XX | 32 | 133 | 0.57 | 7.67 | 1.12 | 11 | 341 | 0.56 | 217 | 500 |
82258XX | 40 | 259 | 0.46 | 8.49 | 1.12 | 12 | 421 | 0.42 | 254 | 500 |
Product Details:
Number of Core | 1 Core |
Type | EB |
Conductor | Soft / annealed Plain Copper |
Insulation | PVC, Lead-free |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
83121XX* | 5 | 7/9/0.32 | 0.32 | 3.1 | 0.6 | 4.3 | 4.7 | 57 | 3.71 | 50 | 500 |
83126XX | 9 | 7/16/0.32 | 0.32 | 4.2 | 0.6 | 5.4 | 5.8 | 94 | 2.09 | 72 | 500 |
83127XX | 10 | 19/6/0.32 | 0.32 | 4.2 | 0.6 | 5.5 | 5.9 | 96 | 2.05 | 72 | 500 |
83155XX | 15 | 19/9/0.32 | 0.32 | 5.3 | 0.6 | 6.5 | 6.9 | 140 | 1.37 | 94 | 500 |
Product Details:
Insulation | Electron Beam Cross-Linked Polyolefin |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +125 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82361XX* | 13 | 133 | 0.36 | 4.83 | 1.52 | 8.6 | 166 | 1.4 | 120 | 500 |
82362XX | 19 | 133 | 0.46 | 6.09 | 1.65 | 10.5 | 257 | 0.94 | 153 | 500 |
82363XX | 32 | 133 | 0.57 | 7.67 | 1.65 | 12 | 373 | 0.56 | 205 | 500 |
82358XX | 40 | 259 | 0.46 | 8.49 | 1.65 | 13 | 453 | 0.42 | 257 | 500 |
Product Details:
Insulation | PVC, Lead-free |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +70 deg C |
Standard | IS 2465 |
Test Voltage | 3 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Approx. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
83028XX* | 16 | 126 | 0.4 | 5.7 | 1 | 8.1 | 171 | 1.21 | 90 | 500 |
83030XX | 25 | 196 | 0.4 | 7.1 | 1.2 | 10 | 263 | 0.78 | 118 | 500 |
83032XX | 35 | 276 | 0.4 | 8.5 | 12 | 11.4 | 357 | 0.554 | 146 | 500 |
83034XX | 50 | 396 | 0.4 | 10.3 | 1.4 | 13.7 | 506 | 0.386 | 185 | 500 |
83037XX | 70 | 360 | 0.5 | 12.4 | 1.4 | 15.8 | 703 | 0.272 | 237 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | XLPE |
Color | Black |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +90 deg C |
Standard | Volvo type |
Rated Voltage | 750 V |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Nominal Thickness of sheath | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Overall Diameter Nom | Weight Approx. | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86406XX* | 10 | 74 | 0.41 | 0.7 | 0.8 | 7.3 | 121 | 1.78 | 60 | 500 |
86408XX | 16 | 118 | 0.41 | 0.7 | 0.8 | 8.3 | 180 | 1.21 | 76 | 500 |
86410XX | 25 | 183 | 0.41 | 0.7 | 0.8 | 9.7 | 280 | 0.78 | 96 | 500 |
86413XX | 35 | 259 | 0.41 | 0.7 | 0.8 | 10.9 | 360 | 0.554 | 120 | 500 |
86416XX | 50 | 382 | 0.41 | 0.8 | 1 | 13 | 510 | 0.386 | 155 | 500 |
Product Details:
No. of Core | Single |
Insulation | PVC, Lead-free |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Color | Black |
Conductor Material | E- Cu ETP1 |
Other Details:
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82461XX* | 13 | 133 | 0.36 | 4.83 | 1.09 | 7.8 | 141 | 1.4 | 93 | 500 |
82462XX | 19 | 133 | 0.46 | 6.09 | 1.12 | 9.5 | 205 | 0.94 | 119 | 500 |
82463XX | 32 | 133 | 0.57 | 7.67 | 1.12 | 11 | 332 | 0.56 | 161 | 500 |
82458XX | 40 | 259 | 0.46 | 8.49 | 1.12 | 12 | 407 | 0.42 | 190 | 500 |
82434XX | 50 | 1026 | 0.26 | 9.47 | 1.12 | 13 | 511 | 0.36 | 211 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | SAE J1128 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | ||
82106XX* | 0.5 | 7 | 0.31 | 0.93 | 0.74 | 2.8 | 11 | 35.7 | 18 | 1000 | |
82160XX | 0.8 | 16 | 0.26 | 1.21 | 0.76 | 3 | 15 | 22.7 | 23 | 1000 | |
82110XX | 1 | 19 | 0.29 | 1.45 | 0.81 | 3.4 | 18 | 15.4 | 29 | 1000 |
Product Details:
Brand | Siechem |
Temperature Range | - 90 deg C to +260 deg C |
Number of Cores | Single |
Standard | ISO 6722, Class H |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PTFE ( Polytetrafluoroethylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
A87405XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.35 | 5 | 12 | 87.9 | 500 | |
A87406XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 17 | 56.8 | 500 | |
A87408XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 22 | 38.6 | 500 | |
A87410XX | 1 | 32 | 0.21 | 1.4 | 0.24 | 1.95 | 11 | 27 | 25.7 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC Compound |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | ISO 6722 Class B |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance 0 at 20 C | Current Carrying Capacity | Standard Length* | |||||
Nominal CrossSection | No. of Strands | ||||||||||
2mm | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | ||
*A83106XX | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 37.1 | 14 | 1000 | |
A83108XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 24.7 | 18 | 1000 | |
A83110XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 18.5 | 22 | 1000 | |
A83113XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 20 | 12.7 | 28 | 1000 | |
A83114XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 9.42 | 33 | 1000 |
Product Details:
Number of Core | 1 Core |
Type | AEX |
Conductor | Soft / annealed Plain Copper |
Temperature Range | - 40 deg C to +120 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81306XX* | 0.5 | 7 | 0.32 | 1 | 0.5 | 2 | 2.2 | 9 | 32.7 | 17 | 1000 |
81354XX | 0.85 | 11 | 0.32 | 1.2 | 0.5 | 2.2 | 2.4 | 12 | 20.8 | 22 | 1000 |
81312XX | 1.25 | 16 | 0.32 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.3 | 28 | 1000 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Conductor resistance (200C) | Insulation Thickness | Cable Overall Diameter | Weight Apporx | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands/Dia of stands pcs/ pcs / mm | Outside Diameter Approx | Nominal | min | Nominal | min | |||||
mm2 | nos. | mm | mm | mm | mm | mm | mm | kg/km | Amps | mtrs | |
87014XX* | 2 | 37/0.26 | 1.8 | 9.5 | 0.6 | 0.48 | 3 | 3.4 | 25 | 27 | 500 |
87017XX | 3 | 58/0.26 | 2.3 | 6.06 | 0.7 | 0.56 | 3.7 | 4 | 36 | 36 | 500 |
87021XX | 5 | 7/9/0.32 | 3.1 | 3.71 | 0.8 | 0.64 | 4.7 | 5 | 60 | 50 | 500 |
87025XX | 8 | 7/22/0.26 | 4.2 | 2.32 | 0.9 | 0.72 | 6 | 6.3 | 91 | 69 | 500 |
Product Details:
Brand | Siechem |
Insulation | PVC |
No. of Cores | Single core |
Standard | ISO 6722 Class B |
Temperature Range | - 40 deg C to +100 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness | Cable | Standard Length | ||||||
Nominal CrossSection | No. of Strands | Diameter of Single wire max. | Conductor Diameter max. | Overall Diameter Max. | Weight Approx. | Current Carrying Capacity | Max. Conductor Resistance 200 C | |||
2 mm | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
*A83306XX | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 12 | 37.1 | 500 |
A83308XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 16 | 24.7 | 500 |
A83310XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 19 | 18.5 | 500 |
A83313XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 15 | 25 | 12.7 | 500 |
Product Details:
Conductor Material | Copper |
Test Voltage, 1min | 3.5 kV AC / 8.4 kV DC |
Min. Bending Radius (fixed) | 4 X Cable dia |
Insulation | Sietherm 155 |
Insulation Colour | White |
Screening | Annealed Tinned Copper Conductor |
Outer Sheath | AX 150 |
Sheath Color | Orange |
Temperature Range | - 40 deg C to +150 deg C |
Voltage Rating (U0/U) | 600V AC / 1000V AC |
Part Number | Conductor Construction | Insulation Thickness Normal | Screen Wire Dia (Normal) | Outer Sheath Thickness (Normal) | Overall Diameter | Weight Approx. | Max. Conductor Resistance at 20°C | Standard Length* | ||
Size | No. of Strands | Diameter of Single wire Max. | ||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
A898130910 | 2.5 | 50 | 0.26 | 0.35 | 0.1 | 0.55 | 5.0 ± 0.3 | 50 | 7.6 | 500 |
A898190910 | 4 | 56 | 0.31 | 0.4 | 0.1 | 0.6 | 5.8 ± 0.3 | 70 | 4.71 | 500 |
A898230910 | 6 | 84 | 0.31 | 0.4 | 0.1 | 0.7 | 6.6 ± 0.3 | 100 | 3.14 | 500 |
A898270910 | 10 | 78 | 0.41 | 0.6 | 0.1 | 0.85 | 8.4 ± 0.3 | 155 | 1.82 | 500 |
A898280910 | 16 | 126 | 0.41 | 0.65 | 0.15 | 0.85 | 9.8 ± 0.3 | 230 | 1.16 | 500 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | Electron Beam Cross-Linked Vinyl |
Temperature Range | - 40 deg C to +100 deg C |
No. of Cores | Single core |
Standard | JASO D D 608 |
Test Voltage | 1 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter | Weight Approx. | ||||||
Normal | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81106XX* | 0.5 | 7 | 0.32 | 1 | 0.5 | 2 | 2.2 | 9 | 32.7 | 15 | 1000 |
81154XX | 0.85 | 11 | 0.32 | 1.2 | 0.5 | 2.2 | 2.4 | 12 | 20.8 | 19 | 1000 |
81112XX | 1.25 | 16 | 0.32 | 1.5 | 0.6 | 2.7 | 2.9 | 17 | 14.3 | 25 | 1000 |
81114XX | 2 | 26 | 0.32 | 1.9 | 0.6 | 3.1 | 3.4 | 26 | 8.81 | 34 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Standard | JASO D 611 |
Test Voltage | 1 kV |
EB | Grounding Bond |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter | Weight Approx. | ||||||
Normal | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
83226XX* | 9 | 112 | 0.32 | 4.2 | 1 | 6.2 | 6.5 | 102 | 2.09 | 73 | 500 |
83255XX | 15 | 171 | 0.32 | 5.3 | 1.1 | 7.5 | 8 | 152 | 1.37 | 95 | 500 |
83256XX | 20 | 247 | 0.32 | 6.5 | 1.1 | 8.7 | 9.3 | 210 | 0.966 | 120 | 500 |
83257XX | 30 | 361 | 0.32 | 7.8 | 1.4 | 10.6 | 11.3 | 311 | 0.647 | 150 | 500 |
Product Details:
Insulation | PVC, Lead-free |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +70 deg C |
Standard | IS 2465 |
Test Voltage | 3 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82906XX* | 0.5 | 16 | 0.2 | 0.93 | 0.6 | 2.5 | 17 | 39 | 11 | 1000 |
82908XX | 0.75 | 24 | 0.2 | 1.14 | 0.6 | 2.7 | 25 | 26 | 13 | 1000 |
82910XX | 1 | 32 | 0.2 | 1.32 | 0.7 | 3.1 | 28 | 19.5 | 16 | 1000 |
82913XX | 1.5 | 30 | 0.2 | 1.6 | 0.7 | 3.4 | 38 | 13.3 | 20 | 1000 |
Product Details:
Brand | Siechem |
Number Of Cores | Single Core |
I Deal In | New Only |
Temperature Range | - 40 to +85 Degree C |
Country of Origin | Made in India |
Conductor Material | Copper |
Insulation Material | PVC |
Voltage Rating | 60 Volts |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current carrying capacity | Standard Length* | |||
Size | No. of Strands | Diameter of Single wire max. | Overall Diameter Max | Weight Approx | ||||
mm2 | nos. | mm | mm | mm | kg/km | Amps | mtrs | |
A88106XX* | 0.5 | 7 | 0.31 | 0.91 | 3.1 | 14 | 14 | 500 |
A88160XX | 0.8 | 16 | 0.26 | 0.94 | 3.4 | 20 | 18 | 500 |
A88110XX | 1 | 19 | 0.29 | 1.02 | 3.7 | 25 | 24 | 500 |
A88111XX | 2 | 19 | 0.36 | 1.04 | 4.2 | 33 | 32 | 500 |
A88117XX | 3 | 19 | 0.45 | 1.17 | 5.1 | 49 | 43 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 to +85 Degree C |
Standard | SAE J1128 |
Country of Origin | Made in India |
Insulation | PVC |
No. of Cores | Single core |
Test Voltage | 1 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current carrying capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Diameter of Single wire max | Overall Diameter Max | Weight Approx. | ||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | mtrs | |
85102XX* | 0.22 | 7 | 0.21 | 0.63 | 0.4 | 1.5 | 5 | 7 | 500 |
85105XX | 0.35 | 7 | 0.26 | 0.78 | 0.4 | 1.7 | 6 | 9 | 500 |
85106XX | 0.5 | 7 | 0.31 | 0.93 | 0.4 | 1.9 | 8 | 12 | 500 |
85160XX | 0.8 | 16 | 0.26 | 1.21 | 0.4 | 2.2 | 10 | 17 | 500 |
85110XX | 1 | 19 | 0.29 | 1.45 | 0.4 | 2.4 | 13 | 22 | 500 |
Product Details:
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | SAE J1128 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Number of Core | 1 Core |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82006XX* | 0.5 | 7 | 0.31 | 0.93 | 0.58 | 2.4 | 11 | 35.7 | 17 | 1000 |
82060XX | 0.8 | 16 | 0.26 | 1.21 | 0.58 | 2.5 | 15 | 22.7 | 22 | 1000 |
82010XX | 1 | 19 | 0.29 | 1.45 | 0.58 | 2.9 | 20 | 15.4 | 28 | 1000 |
82014XX | 2 | 19 | 0.36 | 1.8 | 0.58 | 3.2 | 29 | 9.3 | 38 | 500 |
Product Details:
Brand | Siechem |
Number Of Cores | Single |
Standard | Volvo type |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +70 deg C |
Rated voltage two-coloured | 100 V |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
86806XX* | 0.5 | 16 | 0.21 | 1.1 | 0.6 | 2.6 | 9 | 39 | 8 | 500 |
86808XX | 0.75 | 24 | 0.21 | 1.3 | 0.6 | 2.8 | 11 | 26 | 10 | 500 |
86810XX | 1 | 32 | 0.21 | 1.5 | 0.6 | 3 | 13 | 19.5 | 12 | 500 |
Product Details:
Number of Core | 1 Core |
Insulation | PVC |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +125 deg C |
Standard | Volvo type |
Rated Voltage | 50 V |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | ||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
86928XX* | 16 | 536 | 0.2 | 5.5 | 1 | 7.5 | 177 | 1.16 | 1000 |
86930XX | 25 | 826 | 0.2 | 9.7 | 1.3 | 9.7 | 275 | 0.74 | 1000 |
86932XX | 35 | 1184 | 0.2 | 11.2 | 1.3 | 11.2 | 369 | 0.527 | 1000 |
86934XX | 50 | 1144 | 0.23 | 13 | 1.5 | 13 | 525 | 0.368 | 500 |
Product Details:
Insulation Material | XLPE |
Conductor Type | Solid |
Temperature Range | - 40 deg C to +100 deg C |
Standard | Volvo type |
Rated Voltage | 750 V |
Sheath | PVC Compound type TI 3 |
Conductor | IEC 60228 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Nominal Thickness of sheath | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Overall Diameter | Weight Approx | |||||||
Normal | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86708XX* | 16 | 112 | 0.41 | 0.7 | 0.8 | 8.3 | 8.5 | 180 | 1.21 | 76 | 500 |
86710XX | 25 | 183 | 0.41 | 0.7 | 0.8 | 9.7 | 9.9 | 280 | 0.78 | 96 | 500 |
86713XX | 35 | 259 | 0.41 | 0.7 | 0.8 | 10.9 | 11.2 | 360 | 0.554 | 120 | 500 |
86716XX | 50 | 382 | 0.41 | 0.8 | 1 | 13 | 13.4 | 510 | 0.386 | 155 | 500 |
Product Details:
Brand | Siechem |
Conductor | Copper |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Insulation | PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A82305XX* | 0.35 | 7 | 0.27 | 0.9 | 0.25 | 1.3 | 5 | 9 | 54.4 | 2000 |
A82306XX | 0.5 | 19 | 0.19 | 1.1 | 0.28 | 1.6 | 6 | 11 | 37.1 | 2000 |
A82308XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 15 | 24.7 | 2000 |
A82310XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 18 | 18.5 | 2000 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC Compound |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A82406XX** | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 11 | 37.1 | 500 |
A82408XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 14 | 24.7 | 500 |
A82410XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 17 | 18.5 | 500 |
A82413XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 14 | 22 | 12.7 | 500 |
A82414XX | 2 | 19 | 0.38 | 2 | 0.25 | 2.4 | 20 | 27 | 9.42 | 500 |
Product Details:
Brand | Siechem |
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A81306XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 18 | 37.1 | 1000 |
A81308XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 23 | 24.7 | 1000 |
A81310XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 28 | 18.5 | 1000 |
A81313XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 35 | 12.7 | 1000 |
A81314XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 42 | 9.42 | 1000 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | PE-X |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class C |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84305XX * | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 12 | 54.4 | 500 |
84306XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
84308XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 20 | 24.7 | 500 |
84310XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 24 | 18.5 | 500 |
84313XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +125 deg C (3000 Hours) |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722, ClassC |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PE-X with properties according to ISO 6722 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84202XX* | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 9 | 84.8 | 500 |
84205XX | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
84206XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 15 | 37.1 | 500 |
84208XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 20 | 24.7 | 500 |
84210XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 24 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +150 deg C |
Voltage | 60 V |
Conductor | Copper |
Insulation | EBXL |
No. of Cores | 1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Max. Conductor Resistance at 200C | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84105XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
84106XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 15 | 37.1 | 500 |
84108XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
Product Details:
Brand | Siechem |
Insulated material | EBXL Special polymer sheathed |
Conductor Type | Soft-annealed electrolytic Copper construction |
Number Of Core | Single |
Temperature Range | - 40 deg C to +150 deg C |
Voltage | 60 V |
Scrape Abrasion | SA 2 as per volvo std 525-0001 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | ||||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Max. | Overall Diameter | Weight Approx. | ||||||
Min. | Normal | Max. | |||||||||
mm2 | nos. | mm | mm | mm | mm | mm | mm | kg/km | Amps | kg/km | |
86005XX* | 0.35 | 7 | 0.27 | 0.8 | 0.35 | 1.2 | 1.3 | 1.4 | 5 | 13 | 52 |
86006XX | 0.5 | 19 | 0.19 | 1 | 0.35 | 1.4 | 1.5 | 1.6 | 7 | 16 | 37.1 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft / annealed Plain Copper |
Insulation | Electron Beam Crossed Linked Polyolefin Class E |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
A84206XX* * | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 37.1 | 17 | 500 |
A84208XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 22.7 | 22 | 500 |
A84210XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 18.5 | 26 | 500 |
A84213XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 15 | 12.7 | 34 | 500 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Number Of Core | Single |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max | Conductor Diameter Max | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A84105XX* | 0.35 | 7 | 0.27 | 0.9 | 0.3 | 1.3 | 5 | 13 | 54.4 | 2000 |
A84106XX | 0.5 | 19 | 0.19 | 1.1 | 0.3 | 1.6 | 6 | 18 | 37.1 | 2000 |
A84108XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 23 | 24.7 | 2000 |
A84110XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 28 | 18.5 | 2000 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | Electron Beam Crossed Linked Polyolefin Class E |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max | Overall Diameter Weight Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A84006XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 20 | 37.1 | 1000 |
A84008XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 25 | 24.7 | 1000 |
A84010XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 30 | 18.5 | 1000 |
A84013XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 38 | 12.7 | 1000 |
A84014XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 45 | 9.42 | 1000 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Temperature Range | - 40 deg C to +125 deg C |
No. of Cores | 1 |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | No. of Strands | Conductor Diameter max. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A81506XX* * | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.4 | 6 | 16 | 37.1 | 500 |
A81508XX | 0.75 | 19 | 0.24 | 1.3 | 0.35 | 1.6 | 8 | 20 | 24.7 | 500 |
A81510XX | 1 | 19 | 0.27 | 1.5 | 0.35 | 1.75 | 10 | 24 | 18.5 | 500 |
A81513XX | 1.5 | 19 | 0.33 | 1.8 | 0.35 | 2.1 | 15 | 32 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 90 deg C to +260 deg C |
Number of Cores | Single |
Standard | ISO 6722, Class H |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PTFE ( Polytetrafluoroethylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
A87302XX * | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 12 | 87.9 | 500 | |
A87305XX | 0.35 | 7 | 0.27 | 0.8 | 0.2 | 1.35 | 5 | 15 | 56.8 | 500 | |
A87306XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 21 | 38.6 | 500 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | PFA |
No. of Cores | 1 |
Temperature Range | - 65 deg C to +260 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class H |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | No. of Strands | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
85005XX* | 0.35 | 7 | 0.25 | 0.8 | 0.2 | 1.3 | 4 | 15 | 52 | 500 |
85006XX | 0.5 | 19 | 0.18 | 1 | 0.22 | 1.6 | 6 | 20 | 37.1 | 500 |
85008XX | 0.75 | 19 | 0.22 | 1.2 | 0.24 | 1.9 | 9 | 27 | 24.7 | 500 |
85010XX | 1 | 19 | 0.25 | 1.35 | 0.24 | 2.1 | 11 | 32 | 18.5 | 500 |
85013XX | 1.5 | 19 | 0.31 | 1.7 | 0.24 | 2.4 | 16 | 41 | 12.7 | 500 |
Product Details:
Temperature Range | - 65 deg C to +210 deg C |
Brand | Siechem |
Conductor | Soft-annealed electrolytic Copper |
Insulation | FEP |
No. of Cores | 1 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84905XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 15 | 52 | 500 |
84906XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 19 | 37.1 | 500 |
84908XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84910XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84913XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 65 deg C to +210 deg C |
No. Of Core | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | LV 112-1 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | FEP (Fluorinated Ethylene propylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
84805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 4 | 14 | 54.4 | 500 |
84806XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 19 | 37.1 | 500 |
84808XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84810XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84813XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 80 deg C to +200 deg C |
Conductor | Copper |
Insulation | Silicon Rubber |
Standard | ISO 6722 , Class F |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87127XX* | 10 | 50 | 0.52 | 4.5 | 0.8 | 6.5 | 55 | 105 | 3.03 | 500 |
A87128XX | 16 | 78 | 0.52 | 5.8 | 0.8 | 8.3 | 76 | 141 | 1.93 | 500 |
A87130XX | 25 | 122 | 0.52 | 7.2 | 1.04 | 10.4 | 117 | 184 | 1.24 | 500 |
A87132XX | 35 | 172 | 0.52 | 8.5 | 1.04 | 11.6 | 152 | 226 | 0.878 | 500 |
A87134XX | 50 | 247 | 0.52 | 10.5 | 1.2 | 13.5 | 213 | 287 | 0.613 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 80 deg C to +200 deg C |
No. Of Core | Single |
Standard | ISO 6722 , Class F |
Test Voltage | 3 kV |
Conductor | Copper |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87005XX * | 0.35 | 12 | 0.21 | 0.9 | 0.5 | 2 | 7 | 16 | 54.4 | 500 |
A87006XX | 0.5 | 16 | 0.21 | 1 | 0.6 | 2.3 | 10 | 21 | 37.1 | 500 |
A87008XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 26 | 24.7 | 500 |
A87010XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 31 | 18.5 | 500 |
A87013XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3.1 | 21 | 40 | 12.7 | 500 |
Product Details:
Conductor Material | Copper |
Brand | Siechem |
Temperature Range | - 65 deg C to +180 deg C |
Test Voltage | 3 kV |
Standard | DBL 6312 |
Insulation | ETFE |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
84705XX * | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 14 | 52 | 500 |
84706XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 7 | 18 | 37.1 | 500 |
84708XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 10 | 23 | 24.7 | 500 |
84710XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2 | 12 | 28 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | 65 deg C to +180 deg C (3000 Hours) |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg /km | mtrs | |
84605XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 13 | 52 | 500 |
84606XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 18 | 37.1 | 500 |
84608XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 23 | 24.7 | 500 |
84610XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 28 | 18.5 | 500 |
84613XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 36 | 12.7 | 500 |
Product Details:
Conductor Material | Copper |
Insulation | FEP |
No. of Cores | Single core |
Temperature Range | - 65 deg C to +210 deg C |
Test Voltage | 3 kV |
Standard | LV 112-1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 4 | 14 | 54.4 | 500 |
84806XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 19 | 37.1 | 500 |
84808XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84810XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84813XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 40 deg C to +150 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722,Class D |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | TPE-E |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84405XX* | 0.35 | 7 | 0.26 | 0.8 | 0.35 | 1.3 | 5 | 12 | 52 | 500 |
84406XX | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.6 | 6 | 16 | 37.1 | 500 |
84408XX | 0.75 | 19 | 0.23 | 1.2 | 0.35 | 1.9 | 9 | 22 | 24.1 | 500 |
84410XX | 1 | 19 | 0.26 | 1.35 | 0.35 | 2.1 | 11 | 26 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | -40 deg C to +105 deg C |
No. Of Core | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | PSA STE 9641879499 IR |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.4 | 5 | 10 | 55.9 | 500 |
83806XX | 0.5 | 16 | 0.21 | 1 | 0.28 | 1.7 | 7 | 14 | 37.1 | 500 |
83808XX | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 1.9 | 10 | 17 | 24.7 | 500 |
83810XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.15 | 12 | 21 | 19.5 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +125 deg C |
Insulation | Plasticized PVC |
No. of Cores | 1 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83705XX* | 0.35 | 12 | 0.21. | 0.9 | 0.2 | 1.4 | 5 | 12 | 54.4 | 500 |
83706XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
83708XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
83710XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 23 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 50 deg C to +125 deg C |
No. Of Core | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Soft PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87505XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A87506XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
A87508XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
A87510XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 23 | 18.5 | 500 |
A87513XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 16 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 50 deg C to +125 deg C (3000 Hours) |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87505XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A87506XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
A87508XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
A87510XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 23 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 50 deg C to +105 deg C (3000 Hours) |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | Bosch 5998342 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Plasticized PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83606XX * | 0.5 | 16 | 0.2 | 1 | 0.28 | 1.6 | 6 | 13 | 37.1 | 500 |
83610XX | 0.75 | 24 | 0.2 | 1.2 | 0.6 | 2.5 | 33 | 19 | 24.7 | 500 |
83613XX | 1 | 32 | 0.2 | 1.4 | 0.3 | 2.1 | 57 | 21 | 18.5 | 500 |
83616XX | 1.5 | 30 | 0.25 | 1.7 | 0.3 | 2.4 | 111 | 27 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | Bosch 5998342 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Soft PVC Cold resistant |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A88406XX* | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 7 | 13 | 37.1 | 500 |
A88410XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.1 | 12 | 21 | 18.5 | 500 |
A88413XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 27 | 12.7 | 500 |
A88416XX | 2.5 | 50 | 0.26 | 2.1 | 0.7 | 3.7 | 33 | 39 | 7.6 | 500 |
Product Details:
Conductor | Copper |
Insulation | Plasticized PVC |
No. of Cores | Single core |
Temperature Range | - 50 deg C to +105 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722,Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | meter | |
83506XX* | 0.5 | 28 | 0.16 | 1.1 | 0.6 | 2.3 | 11 | 15 | 37.7 | 500 |
83508XX | 0.75 | 42 | 0.16 | 1.3 | 0.6 | 2.5 | 14 | 19 | 25.1 | 500 |
83510XX | 1 | 57 | 0.16 | 1.5 | 0.6 | 2.7 | 17 | 23 | 18.8 | 500 |
83513XX | 4.5 | 84 | 0.16 | 1.8 | 0.6 | 3 | 23 | 29 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Insulation | Plasticized PVC |
No. of Cores | Single core |
Test Voltage | 3 kV |
Standard | Bosch 598341 |
Standard type | DBL 6312 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | meter | |
83406XX* | 0.5 | 16 | 0.21 | 01/01/00 | 0.6 | 2.3 | 10 | 16 | 37.1 | 500 |
83408XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 21 | 24.7 | 500 |
83410XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 25 | 18.5 | 500 |
83413XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3 | 21 | 32 | 12.7 | 500 |
Product Details:
Temperature Range | - 40 deg C to +105 deg C |
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Insulation | Plasticized PVC |
No. of Cores | 1 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83306XX * | 0.5 | 16 | 0.21 | 1 | 0.6 | 2.3 | 10 | 15 | 37.1 | 500 |
83308XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 19 | 24.7 | 500 |
83310XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 22 | 18.5 | 500 |
83313XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3 | 21 | 28 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 40 deg C to +105 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | PSA STE 96 41879499 IR |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Plasticized PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.4 | 5 | 11 | 55.9 | 500 |
83806XX | 0.5 | 16 | 0.21 | 1 | 0.28 | 1.7 | 6 | 15 | 37.1 | 500 |
83808XX | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 1.9 | 9 | 19 | 24.1 | 500 |
83810XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.15 | 12 | 23 | 19.5 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +125 deg C (3000 Hours) |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class C |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked EVA (Ethylene Vinyl Acetate) |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath Thickness | Cable | Max. Conductor Resistance at 200 C | Standard Length | |||||
Nominal Cross- Section | No. of Core | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | |||||
mm2 | mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
FLR4G11Y | |||||||||||
8560502 | 0.35 | 2 | 19 | 0.16 | 0.8 | 0.35 | 0.5 | 4.8 | 29 | 54.5 | 500 |
8560602 | 0.5 | 2 | 28 | 0.16 | 1 | 0.35 | 0.55 | 5.2 | 36 | 40.1 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +105 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722, Class B |
Sheath | PVC, Lead-free Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath wall Thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max. | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
85508XX* | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 0.3 | 2.7 | 20 | 20 | 24.7 | 500 |
85510XX | 1 | 32 | 0.21 | 1.35 | 0.3 | 0.3 | 2.9 | 23 | 24 | 18.5 | 500 |
85513XX | 1.5 | 30 | 0.26 | 1.7 | 0.3 | 0.3 | 3.2 | 29 | 30 | 12.7 | 500 |
Product Details:
Conductor | Copper |
Insulation | PVC |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +105 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Sheath Thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
85419XX* | 4 | 56 | 0.31 | 2.75 | 0.8 | 2 | 8.4 | 123 | 61 | 4.71 | 500 | |
85423XX | 6 | 84 | 0.31 | 3.3 | 0.8 | 2 | 9 | 149 | 77 | 3.1 | 500 | |
85427XX | 10 | 80 | 0.41 | 4.5 | 1 | 3 | 12.8 | 267 | 263 | 1.82 | 500 |
Product Details:
Conductor Material | Copper |
Temperature Range | - 40 deg C to +105 deg C |
Brand | Siechem |
Insulation | Plasticized PVC |
Standard | LV112-1 |