Product Details:
Brand | Siechem |
Country of Origin | Made in India |
Conductor | E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked Polyethylene |
No. of Cores | Single core |
Temperature Range | - 40 to +120 Degree C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81406XX* | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.2 | 8 | 36.7 | 16 | 1000 |
81408XX | 0.75 | 30 | 0.18 | 1.1 | 0.5 | 2.2 | 2.4 | 11 | 24.4 | 20 | 1000 |
81412XX | 1.25 | 50 | 0.18 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.7 | 28 | 1000 |
Product Details:
Brand | Siechem |
Number Of Cores | Single Core |
Country of Origin | Made in India |
Insulation | PVC,Lead-free |
Conductor Material | Copper |
Temperature Range | - 40 to +80 Degree C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
80404XX* | 0.3 | 15 | 0.18 | 0.8 | 0.5 | 1.8 | 1.9 | 7 | 48.9 | 10 | 1000 |
80406XX | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.1 | 9 | 36.7 | 12 | 1000 |
80408XX | 0.75 | 30 | 0.18 | 1.2 | 0.5 | 2.2 | 2.3 | 12 | 24.4 | 15 | 1000 |
80412XX | 1.25 | 50 | 0.18 | 1.5 | 0.5 | 2.5 | 2.6 | 17 | 14.7 | 20 | 1000 |
Product Details:
Brand | Siechem |
Temperature Range | - 90 deg C to +260 deg C |
Number of Cores | Single |
Standard | ISO 6722, Class H |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PTFE ( Polytetrafluoroethylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
A87405XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.35 | 5 | 12 | 87.9 | 500 | |
A87406XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 17 | 56.8 | 500 | |
A87408XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 22 | 38.6 | 500 | |
A87410XX | 1 | 32 | 0.21 | 1.4 | 0.24 | 1.95 | 11 | 27 | 25.7 | 500 |
Product Details:
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Max. Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81206XX* | 0.5 | 20 | 0.18 | 1 | 0.5 | 2 | 2.2 | 9 | 36.7 | 14 | 1000 |
81208XX | 0.75 | 30 | 0.18 | 1.1 | 0.5 | 2.2 | 2.4 | 11 | 24.4 | 18 | 1000 |
81212XX | 1.25 | 50 | 0.18 | 1.5 | 0.6 | 2.7 | 2.9 | 18 | 14.7 | 25 | 1000 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC Compound |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | ISO 6722 Class B |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance 0 at 20 C | Current Carrying Capacity | Standard Length* | |||||
Nominal CrossSection | No. of Strands | ||||||||||
2mm | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | ||
*A83106XX | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 37.1 | 14 | 1000 | |
A83108XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 24.7 | 18 | 1000 | |
A83110XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 18.5 | 22 | 1000 | |
A83113XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 20 | 12.7 | 28 | 1000 | |
A83114XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 9.42 | 33 | 1000 |
Product Details:
Conductor | Copper |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +100 deg C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81106XX* | 0.5 | 7 | 0.32 | 1 | 0.5 | 2 | 2.2 | 9 | 32.7 | 15 | 1000 |
81154XX | 0.85 | 11 | 0.32 | 1.2 | 0.5 | 2.2 | 2.4 | 12 | 20.8 | 19 | 1000 |
81112XX | 1.25 | 16 | 0.32 | 1.5 | 0.6 | 2.7 | 2.9 | 17 | 14.3 | 25 | 1000 |
Product Details:
Insulation | PVC, Lead-free |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +70 deg C |
Standard | IS 2465 |
Test Voltage | 3 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82906XX* | 0.5 | 16 | 0.2 | 0.93 | 0.6 | 2.5 | 17 | 39 | 11 | 1000 |
82908XX | 0.75 | 24 | 0.2 | 1.14 | 0.6 | 2.7 | 25 | 26 | 13 | 1000 |
82910XX | 1 | 32 | 0.2 | 1.32 | 0.7 | 3.1 | 28 | 19.5 | 16 | 1000 |
82913XX | 1.5 | 30 | 0.2 | 1.6 | 0.7 | 3.4 | 38 | 13.3 | 20 | 1000 |
Product Details:
Brand | Siechem |
Number Of Cores | Single Core |
I Deal In | New Only |
Temperature Range | - 40 to +85 Degree C |
Country of Origin | Made in India |
Conductor Material | Copper |
Insulation Material | PVC |
Voltage Rating | 60 Volts |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current carrying capacity | Standard Length* | |||
Size | No. of Strands | Diameter of Single wire max. | Overall Diameter Max | Weight Approx | ||||
mm2 | nos. | mm | mm | mm | kg/km | Amps | mtrs | |
A88106XX* | 0.5 | 7 | 0.31 | 0.91 | 3.1 | 14 | 14 | 500 |
A88160XX | 0.8 | 16 | 0.26 | 0.94 | 3.4 | 20 | 18 | 500 |
A88110XX | 1 | 19 | 0.29 | 1.02 | 3.7 | 25 | 24 | 500 |
A88111XX | 2 | 19 | 0.36 | 1.04 | 4.2 | 33 | 32 | 500 |
A88117XX | 3 | 19 | 0.45 | 1.17 | 5.1 | 49 | 43 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 to +85 Degree C |
Standard | SAE J1128 |
Country of Origin | Made in India |
Insulation | PVC |
No. of Cores | Single core |
Test Voltage | 1 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current carrying capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Diameter of Single wire max | Overall Diameter Max | Weight Approx. | ||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | mtrs | |
85102XX* | 0.22 | 7 | 0.21 | 0.63 | 0.4 | 1.5 | 5 | 7 | 500 |
85105XX | 0.35 | 7 | 0.26 | 0.78 | 0.4 | 1.7 | 6 | 9 | 500 |
85106XX | 0.5 | 7 | 0.31 | 0.93 | 0.4 | 1.9 | 8 | 12 | 500 |
85160XX | 0.8 | 16 | 0.26 | 1.21 | 0.4 | 2.2 | 10 | 17 | 500 |
85110XX | 1 | 19 | 0.29 | 1.45 | 0.4 | 2.4 | 13 | 22 | 500 |
Product Details:
Brand | Siechem |
Number Of Cores | Single |
Standard | Volvo type |
No. of Cores | 1 |
Temperature Range | - 40 to +70 deg C |
Rated voltage two-coloured | 100 V |
Wire length | 500 Meter |
Part Number |
Conductor Construction | Insulation Wall Thickness Normal |
Cable | Max. Conductor Resistance at 200C |
Current Carrying Capacity |
Standard Length* |
||||
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Normal |
Overall Diameter Max. |
Weight Approx |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
86806XX* | 0.5 | 16 | 0.21 | 1.1 | 0.6 | 2.6 | 9 | 39 | 8 | 500 |
86808XX | 0.75 | 24 | 0.21 | 1.3 | 0.6 | 2.8 | 11 | 26 | 10 | 500 |
86810XX | 1 | 32 | 0.21 | 1.5 | 0.6 | 3 | 13 | 19.5 | 12 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC Compound |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A82406XX** | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 11 | 37.1 | 500 |
A82408XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 14 | 24.7 | 500 |
A82410XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 17 | 18.5 | 500 |
A82413XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 14 | 22 | 12.7 | 500 |
A82414XX | 2 | 19 | 0.38 | 2 | 0.25 | 2.4 | 20 | 27 | 9.42 | 500 |
Product Details:
Brand | Siechem |
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A81306XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 18 | 37.1 | 1000 |
A81308XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 23 | 24.7 | 1000 |
A81310XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 28 | 18.5 | 1000 |
A81313XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 35 | 12.7 | 1000 |
A81314XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 42 | 9.42 | 1000 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | PE-X |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class C |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84305XX * | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 12 | 54.4 | 500 |
84306XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
84308XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 20 | 24.7 | 500 |
84310XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 24 | 18.5 | 500 |
84313XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +125 deg C (3000 Hours) |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722, ClassC |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PE-X with properties according to ISO 6722 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84202XX* | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 9 | 84.8 | 500 |
84205XX | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
84206XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 15 | 37.1 | 500 |
84208XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 20 | 24.7 | 500 |
84210XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 24 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +150 deg C |
Voltage | 60 V |
Conductor | Copper |
Insulation | EBXL |
No. of Cores | 1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Max. Conductor Resistance at 200C | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84105XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
84106XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 15 | 37.1 | 500 |
84108XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft / annealed Plain Copper |
Insulation | Electron Beam Crossed Linked Polyolefin Class E |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
A84206XX* * | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 37.1 | 17 | 500 |
A84208XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 22.7 | 22 | 500 |
A84210XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 18.5 | 26 | 500 |
A84213XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 15 | 12.7 | 34 | 500 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Number Of Core | Single |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max | Conductor Diameter Max | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A84105XX* | 0.35 | 7 | 0.27 | 0.9 | 0.3 | 1.3 | 5 | 13 | 54.4 | 2000 |
A84106XX | 0.5 | 19 | 0.19 | 1.1 | 0.3 | 1.6 | 6 | 18 | 37.1 | 2000 |
A84108XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 23 | 24.7 | 2000 |
A84110XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 28 | 18.5 | 2000 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Temperature Range | - 40 deg C to +125 deg C |
No. of Cores | 1 |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | No. of Strands | Conductor Diameter max. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A81506XX* * | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.4 | 6 | 16 | 37.1 | 500 |
A81508XX | 0.75 | 19 | 0.24 | 1.3 | 0.35 | 1.6 | 8 | 20 | 24.7 | 500 |
A81510XX | 1 | 19 | 0.27 | 1.5 | 0.35 | 1.75 | 10 | 24 | 18.5 | 500 |
A81513XX | 1.5 | 19 | 0.33 | 1.8 | 0.35 | 2.1 | 15 | 32 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 90 deg C to +260 deg C |
Number of Cores | Single |
Standard | ISO 6722, Class H |
Test Voltage | 3 kV (r.m.s.) for cables |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PTFE ( Polytetrafluoroethylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
A87302XX * | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 12 | 87.9 | 500 | |
A87305XX | 0.35 | 7 | 0.27 | 0.8 | 0.2 | 1.35 | 5 | 15 | 56.8 | 500 | |
A87306XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 21 | 38.6 | 500 |
Product Details:
Temperature Range | - 65 deg C to +210 deg C |
Brand | Siechem |
Conductor | Soft-annealed electrolytic Copper |
Insulation | FEP |
No. of Cores | 1 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84905XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 15 | 52 | 500 |
84906XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 19 | 37.1 | 500 |
84908XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84910XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84913XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 65 deg C to +210 deg C |
No. Of Core | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | LV 112-1 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | FEP (Fluorinated Ethylene propylene) |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
84805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 4 | 14 | 54.4 | 500 |
84806XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 7 | 19 | 37.1 | 500 |
84808XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 25 | 24.7 | 500 |
84810XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
84813XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 80 deg C to +200 deg C |
Conductor | Copper |
Insulation | Silicon Rubber |
Standard | ISO 6722 , Class F |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87127XX* | 10 | 50 | 0.52 | 4.5 | 0.8 | 6.5 | 55 | 105 | 3.03 | 500 |
A87128XX | 16 | 78 | 0.52 | 5.8 | 0.8 | 8.3 | 76 | 141 | 1.93 | 500 |
A87130XX | 25 | 122 | 0.52 | 7.2 | 1.04 | 10.4 | 117 | 184 | 1.24 | 500 |
A87132XX | 35 | 172 | 0.52 | 8.5 | 1.04 | 11.6 | 152 | 226 | 0.878 | 500 |
A87134XX | 50 | 247 | 0.52 | 10.5 | 1.2 | 13.5 | 213 | 287 | 0.613 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 80 deg C to +200 deg C |
No. Of Core | Single |
Standard | ISO 6722 , Class F |
Test Voltage | 3 kV |
Conductor | Copper |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87005XX * | 0.35 | 12 | 0.21 | 0.9 | 0.5 | 2 | 7 | 16 | 54.4 | 500 |
A87006XX | 0.5 | 16 | 0.21 | 1 | 0.6 | 2.3 | 10 | 21 | 37.1 | 500 |
A87008XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 26 | 24.7 | 500 |
A87010XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 31 | 18.5 | 500 |
A87013XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3.1 | 21 | 40 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | 65 deg C to +180 deg C (3000 Hours) |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg /km | mtrs | |
84605XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 13 | 52 | 500 |
84606XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 18 | 37.1 | 500 |
84608XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 23 | 24.7 | 500 |
84610XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 28 | 18.5 | 500 |
84613XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 17 | 36 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 40 deg C to +150 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722,Class D |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | TPE-E |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
84405XX* | 0.35 | 7 | 0.26 | 0.8 | 0.35 | 1.3 | 5 | 12 | 52 | 500 |
84406XX | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.6 | 6 | 16 | 37.1 | 500 |
84408XX | 0.75 | 19 | 0.23 | 1.2 | 0.35 | 1.9 | 9 | 22 | 24.1 | 500 |
84410XX | 1 | 19 | 0.26 | 1.35 | 0.35 | 2.1 | 11 | 26 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | -40 deg C to +105 deg C |
No. Of Core | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | PSA STE 9641879499 IR |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.4 | 5 | 10 | 55.9 | 500 |
83806XX | 0.5 | 16 | 0.21 | 1 | 0.28 | 1.7 | 7 | 14 | 37.1 | 500 |
83808XX | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 1.9 | 10 | 17 | 24.7 | 500 |
83810XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.15 | 12 | 21 | 19.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 50 deg C to +125 deg C |
No. Of Core | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Soft PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87505XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A87506XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
A87508XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
A87510XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 23 | 18.5 | 500 |
A87513XX | 1.5 | 19 | 0.32 | 1.7 | 0.24 | 2.4 | 16 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 40 deg C to +105 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | PSA STE 96 41879499 IR |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Plasticized PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83805XX* | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.4 | 5 | 11 | 55.9 | 500 |
83806XX | 0.5 | 16 | 0.21 | 1 | 0.28 | 1.7 | 6 | 15 | 37.1 | 500 |
83808XX | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 1.9 | 9 | 19 | 24.1 | 500 |
83810XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.15 | 12 | 23 | 19.5 | 500 |
Product Details:
Conductor | Copper |
Insulation | PVC |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +105 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722, Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Sheath Thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
85419XX* | 4 | 56 | 0.31 | 2.75 | 0.8 | 2 | 8.4 | 123 | 61 | 4.71 | 500 | |
85423XX | 6 | 84 | 0.31 | 3.3 | 0.8 | 2 | 9 | 149 | 77 | 3.1 | 500 | |
85427XX | 10 | 80 | 0.41 | 4.5 | 1 | 3 | 12.8 | 267 | 263 | 1.82 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +105 deg C |
Standard | DIN 72551 - 6 |
Test Voltage | 3kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | ||||||
Bare | Tinned | ||||||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | ???/km | Amps | mtrs | |
81805XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 52 | 54.5 | 11 | 500 |
81806XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 37.1 | 38.2 | 13 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +105 deg C |
Standard | DIN 72551 - 6 |
Test Voltage | 3kV (r.m.s.) for cables |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Max. | Overall Diameter Max. | Weight Approx | ||||||
Bare | Tinned | ||||||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | ???/km | Amps | mtrs | |
81702XX * | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 84.8 | 86.5 | 8 | 500 |
81705XX | 0.35 | 7 | 0.26 | 0.8 | 0.22 | 1.3 | 5 | 52 | 54.5 | 10 | 500 |
81706XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 37.1 | 38.2 | 13 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +125 deg C |
Number of Cores | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class C |
Outer Sheath | TPE-U |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath Thickness | Cable | Conductor Resistance at 200 C | Standard Length* | ||||||
Nominal Cross- Section | No. of Core | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | Bare | Tinned | ||||
mm2 | mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | ???/km | mtrs | |
8570502* | 0.35 | 2 | 12 | 0.21 | 0.9 | 0.25 | 0.5 | 3.9 | 25 | 52 | 54.5 | 500 |
8570602 | 0.5 | 2 | 19 | 0.19 | 1 | 0.3 | 0.65 | 4.6 | 35 | 37.1 | 40.1 | 500 |
8570602 | 0.5 | 2 | 28 | 0.16 | 1 | 0.3 | 0.65 | 4.6 | 36 | 37.1 | 40.1 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40C to +125C |
Standard | SAEJ 1939/15 |
Test Voltage | 1 kV |
Test Method | SAEJ1128 |
Characteristic Impedance | 120 +/- 12 ohm |
Specific Resistance | 50mohm/m(Max) |
Specific Capacitance | 40 pF/m |
Cable Bending Radius | 4 X Cable Dia |
Part Number | Conductor Construction | Nominal Insulation Thickness | Core Diameter | Sheath Thickness Nominal | Cable Diameter | |||||
Nominal Cross Section | No.of Strands | Strand Diameter Max. | Conductor Diameter Nom. | Min | max | Min | Max | |||
Sq.mm/AWG | Nos | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 Sq.mm | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 Sq.mm | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Brand | Siechem |
Temperature Range | - 40C to +150C |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class D |
Conductor | Soft-annealed electrolytic Copper Cu - ETP1 |
Insulation | TPE- E (Thermoplastic Polyester Elastomer) |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A89302XX* | 0.22 | 7 | 0.2 | 0.6 | 0.2 | 1.2 | 3 | 10 | 84.8 | 500 |
A89305XX | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A89306XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 14 | 37.1 | 500 |
A89308XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 18 | 24.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 950C to +210C (3000 Hours) |
Number of Cores | Single core |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | LV 112-1 |
Wire Code | FLR6Y-B |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A89505XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 15 | 52 | 500 |
A89506XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 7 | 19 | 37.1 | 500 |
A89508XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 10 | 25 | 24.7 | 500 |
A89510XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 30 | 18.5 | 500 |
A89513XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 18 | 38 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3kV |
Standard | ISO 6722, Class C |
Conductor | Copper E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked EVA (Ethylene Vinyl Acetate) |
Siechem is India’s No.1 manufacturer & exporter of Automotive Wires & Cables. We manufacture almost all the types of automotive wires & cables that meet Japanese, Korean, American and European OEM specification. Some of the details are listed below :
JIS C 3406, JASO D 611, JASO D 608, ISO 6722, IS 2465, SAE J 1128, SAE J 1127, SAE J 1678, SAE J 1939/15 Volvo, Ford ES –AU5T -1A348, ES 91110-05, YPES-17-21-005, YPES-17-21-004, DIN 72551-6 & customized to your specification.
Types of Cable: AV, AV-f, AVS, AVS-f, AVSS, AVSS-f, AVSSH-f, AVSSX, AVSSX-f, AVX, AVX-f, AEX, AEX-f, AESSX, AESSX-f, CPE-FR, CPE –FR TW, EB, HEB, HDEB, GPT, HDT, TWP, TXL, GXL, SXL, STT, SGT, STX, SGX, WTA, WXC, RK, SK, RXKB, SXKB, R2, R4, Auto 85, Auto 85-TW, Auto 85-UTW, Auto 100, Auto 100 TW, Auto UTW, Auto 125, Auto 125-TW, Auto 125-UTW, Auto 150, Auto 150-TW, Auto 150-UTW, Auto 175, Auto 175-TW, Auto 175-UTW, ACW 150, Auto 125 P, Auto 125X-A & B, Auto 150 A-A & A-B, Auto 180 E-A & E-B, Auto 200G, Auto 200G AL, Auto 210F-A & B, Auto 260T, Auto 260 R-A & R-B, FLY, FLYW, FLYK, FLRYK, FLYWK, FLRYWK, FLRYW-A & B, FLRY T2 IR, FRLY T3 IR, FLR4Y-A & B, FL91Y-FL11Y, FLYY, FLRY-A,B&H, FLYOY-FLYKOY, FLRYDY, FLR4G11Y-FL4G11Y, FLR2X11Y, FLR31Y11Y, FLRY11Y, FLALRY, FLALRYW, FLR6Y-B, FLR12Y-A, ABS Sensor & CAN BUS UTP.
Product Details:
Brand | Siechem |
No. Of Core | Single |
Conductor | Aluminium 99.7 % 1.25mm2 |
Insulation | Soft -PVC With properties according |
Test Voltage | 3kV (r.m.s.) |
Standard | ISO 6722,Class C |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87908XX* | 0.75 | 11 | 0.3 | 1.3 | 0.24 | 1.9 | 4 | 15 | 43.6 | 500 |
A87910XX | 1 | 16 | 0.29 | 1.5 | 0.24 | 2.1 | 5 | 18 | 32.7 | 500 |
A87912XX | 1.25 | 16 | 0.32 | 1.7 | 0.24 | 2.3 | 6 | 21 | 24.8 | 500 |
A87913XX | 1.5 | 16 | 0.35 | 1.8 | 0.24 | 2.4 | 7 | 23 | 21.2 | 500 |
A87914XX | 2 | 15 | 0.42 | 2 | 0.28 | 2.8 | 9 | 28 | 15.7 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
A81206XX* | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 37.1 | 14 | 500 |
A81208XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 1.6 | 8 | 24.7 | 18 | 500 |
A81210XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 18.5 | 22 | 500 |
A81213XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 15 | 12.7 | 29 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 to +120 Degree C |
Standard | JASO D 608 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81554XX* | 0.85 | 19 | 0.24 | 1.21 | 0.3 | 1.9 | 10 | 21.7 | 20 | 1000 |
81514XX | 2 | 37 | 0.26 | 1.83 | 0.4 | 2.7 | 22 | 9.5 | 35 | 500 |
Product Details:
Insulation | EBXL- CPE- FR |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +125 deg C |
Standards | ISO 6722 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
A82602XX* | 0.22 | 7 | 0.21 | 0.7 | 0.2 | 1.2 | 3 | 84.8 | 9 | 500 |
A82605XX | 0.35 | 7 | 0.26 | 0.9 | 0.2 | 1.4 | 5 | 54.5 | 12 | 500 |
A82606XX | 0.5 | 19 | 0.19 | 1.1 | 0.22 | 1.6 | 6 | 37.1 | 15 | 500 |
A82608XX | 0.75 | 19 | 0.23 | 1.3 | 0.24 | 1.9 | 9 | 24.7 | 20 | 500 |
Product Details:
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | SAE J1128 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81902XX* | 0.22 | 7 | 0.21 | 0.63 | 0.4 | 1.5 | 5 | 84.4 | 9 | 1000 |
81905XX | 0.35 | 7 | 0.26 | 0.78 | 0.4 | 1.7 | 6 | 52 | 13 | 1000 |
81906XX | 0.5 | 7 | 0.31 | 0.93 | 0.4 | 1.9 | 8 | 35.7 | 16 | 1000 |
81960XX | 0.8 | 16 | 0.26 | 1.21 | 0.4 | 2.2 | 11 | 22.7 | 21 | 1000 |
Product Details:
Brand | Siechem |
Insulation | Class 4 |
No. of Cores | Single core |
Rated Voltage | 50 VDC |
Standard | Volvo type |
Temperature Range | - 40 deg C to +150 deg C |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | . Conductor Resistance at 200C | StaC-Max Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86605XX* | 0.35 | 7 | 0.26 | 0.78 | 0.2 | 1.4 | 4.5 | 54.4 | 5 | 500 |
86606XX | 0.5 | 19 | 0.19 | 0.95 | 0.22 | 1.6 | 6 | 37.1 | 8 | 500 |
86608XX | 0.75 | 19 | 0.23 | 0.95 | 0.24 | 1.9 | 9.4 | 24.7 | 10 | 500 |
86610XX | 1 | 32 | 0.2 | 1.5 | 0.24 | 2.1 | 12 | 18.5 | 12 | 500 |
86613XX | 1.5 | 37 | 0.22 | 1.54 | 0.24 | 2.4 | 16 | 12.7 | 16 | 500 |
Product Details:
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | ISO 6722 Class C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Max. Conductor Resistance at 200C | Current Carrying capacity | StandardLength* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
A81105XX** | 0.35 | 7 | 0.27 | 0.9 | 0.3 | 1.4 | 5 | 54.4 | 12 | 2000 |
A81106XX | 0.5 | 19 | 0.19 | 1.1 | 0.3 | 1.6 | 6 | 37.1 | 15 | 2000 |
A81108XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 24.7 | 20 | 2000 |
A81110XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 18.5 | 24 | 2000 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Conductor resistance (200C) | Insulation Thickness | Cable Overall Diameter | Weight Apporx | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands/Dia of stands pcs/ pcs / mm | Outside Diameter Approx | Nominal | min | Nominal | min | |||||
mm2 | nos. | mm | mm | mm | mm | mm | mm | kg/km | Amps | mtrs | |
87014XX* | 2 | 37/0.26 | 1.8 | 9.5 | 0.6 | 0.48 | 3 | 3.4 | 25 | 27 | 500 |
87017XX | 3 | 58/0.26 | 2.3 | 6.06 | 0.7 | 0.56 | 3.7 | 4 | 36 | 36 | 500 |
87021XX | 5 | 7/9/0.32 | 3.1 | 3.71 | 0.8 | 0.64 | 4.7 | 5 | 60 | 50 | 500 |
87025XX | 8 | 7/22/0.26 | 4.2 | 2.32 | 0.9 | 0.72 | 6 | 6.3 | 91 | 69 | 500 |
Product Details:
Number of Core | 1 Core |
Type | EB |
Conductor | Soft / annealed Plain Copper |
Insulation | PVC,Lead-free |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
83121XX* | 5 | 7/9/0.32 | 0.32 | 3.1 | 0.6 | 4.3 | 4.7 | 57 | 3.71 | 50 | 500 |
83126XX | 9 | 7/16/0.32 | 0.32 | 4.2 | 0.6 | 5.4 | 5.8 | 94 | 2.09 | 72 | 500 |
83127XX | 10 | 19/6/0.32 | 0.32 | 4.2 | 0.6 | 5.5 | 5.9 | 96 | 2.05 | 72 | 500 |
83155XX | 15 | 19/9/0.32 | 0.32 | 5.3 | 0.6 | 6.5 | 6.9 | 140 | 1.37 | 94 | 500 |
Product Details:
No. of Core | Single |
Insulation | PVC, Lead-free |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Color | Black |
Conductor Material | E- Cu ETP1 |
Other Details:
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82461XX* | 13 | 133 | 0.36 | 4.83 | 1.09 | 7.8 | 141 | 1.4 | 93 | 500 |
82462XX | 19 | 133 | 0.46 | 6.09 | 1.12 | 9.5 | 205 | 0.94 | 119 | 500 |
82463XX | 32 | 133 | 0.57 | 7.67 | 1.12 | 11 | 332 | 0.56 | 161 | 500 |
82458XX | 40 | 259 | 0.46 | 8.49 | 1.12 | 12 | 407 | 0.42 | 190 | 500 |
82434XX | 50 | 1026 | 0.26 | 9.47 | 1.12 | 13 | 511 | 0.36 | 211 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | SAE J1128 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | ||
82106XX* | 0.5 | 7 | 0.31 | 0.93 | 0.74 | 2.8 | 11 | 35.7 | 18 | 1000 | |
82160XX | 0.8 | 16 | 0.26 | 1.21 | 0.76 | 3 | 15 | 22.7 | 23 | 1000 | |
82110XX | 1 | 19 | 0.29 | 1.45 | 0.81 | 3.4 | 18 | 15.4 | 29 | 1000 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Conductor | Soft-annealed electrolytic Copper E- Cu ETP1 |
Insulation | PVC, Lead-free |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82561XX* | 13 | 133 | 0.36 | 4.83 | 1.52 | 8.6 | 166 | 1.4 | 93 | 500 |
82562XX | 19 | 133 | 0.46 | 6.09 | 1.65 | 10.5 | 257 | 0.94 | 119 | 500 |
82563XX | 32 | 133 | 0.57 | 7.67 | 1.65 | 12 | 373 | 0.56 | 161 | 500 |
82558XX | 40 | 259 | 0.46 | 8.49 | 1.65 | 13 | 455 | 0.42 | 190 | 500 |
82534XX | 50 | 1026 | 0.26 | 9.47 | 1.65 | 14.5 | 545 | 0.36 | 215 | 500 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | Electron Beam Cross-Linked Vinyl |
Temperature Range | - 40 deg C to +100 deg C |
No. of Cores | Single core |
Standard | JASO D D 608 |
Test Voltage | 1 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter | Weight Approx. | ||||||
Normal | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
81106XX* | 0.5 | 7 | 0.32 | 1 | 0.5 | 2 | 2.2 | 9 | 32.7 | 15 | 1000 |
81154XX | 0.85 | 11 | 0.32 | 1.2 | 0.5 | 2.2 | 2.4 | 12 | 20.8 | 19 | 1000 |
81112XX | 1.25 | 16 | 0.32 | 1.5 | 0.6 | 2.7 | 2.9 | 17 | 14.3 | 25 | 1000 |
81114XX | 2 | 26 | 0.32 | 1.9 | 0.6 | 3.1 | 3.4 | 26 | 8.81 | 34 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Standard | JASO D 611 |
Test Voltage | 1 kV |
EB | Grounding Bond |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200 C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter | Weight Approx. | ||||||
Normal | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
83226XX* | 9 | 112 | 0.32 | 4.2 | 1 | 6.2 | 6.5 | 102 | 2.09 | 73 | 500 |
83255XX | 15 | 171 | 0.32 | 5.3 | 1.1 | 7.5 | 8 | 152 | 1.37 | 95 | 500 |
83256XX | 20 | 247 | 0.32 | 6.5 | 1.1 | 8.7 | 9.3 | 210 | 0.966 | 120 | 500 |
83257XX | 30 | 361 | 0.32 | 7.8 | 1.4 | 10.6 | 11.3 | 311 | 0.647 | 150 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 50 deg C to +125 deg C (3000 Hours) |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | DBL 6312 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87505XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A87506XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
A87508XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
A87510XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 23 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Rating | - 50 deg C to +105 deg C (3000 Hours) |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | Bosch 5998342 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Plasticized PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83606XX * | 0.5 | 16 | 0.2 | 1 | 0.28 | 1.6 | 6 | 13 | 37.1 | 500 |
83610XX | 0.75 | 24 | 0.2 | 1.2 | 0.6 | 2.5 | 33 | 19 | 24.7 | 500 |
83613XX | 1 | 32 | 0.2 | 1.4 | 0.3 | 2.1 | 57 | 21 | 18.5 | 500 |
83616XX | 1.5 | 30 | 0.25 | 1.7 | 0.3 | 2.4 | 111 | 27 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | Bosch 5998342 |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Soft PVC Cold resistant |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A88406XX* | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 7 | 13 | 37.1 | 500 |
A88410XX | 1 | 32 | 0.21 | 1.4 | 0.3 | 2.1 | 12 | 21 | 18.5 | 500 |
A88413XX | 1.5 | 30 | 0.26 | 1.7 | 0.24 | 2.4 | 17 | 27 | 12.7 | 500 |
A88416XX | 2.5 | 50 | 0.26 | 2.1 | 0.7 | 3.7 | 33 | 39 | 7.6 | 500 |
Product Details:
Conductor | Copper |
Insulation | Plasticized PVC |
No. of Cores | Single core |
Temperature Range | - 50 deg C to +105 deg C |
Test Voltage | 3 kV |
Standard | ISO 6722,Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | meter | |
83506XX* | 0.5 | 28 | 0.16 | 1.1 | 0.6 | 2.3 | 11 | 15 | 37.7 | 500 |
83508XX | 0.75 | 42 | 0.16 | 1.3 | 0.6 | 2.5 | 14 | 19 | 25.1 | 500 |
83510XX | 1 | 57 | 0.16 | 1.5 | 0.6 | 2.7 | 17 | 23 | 18.8 | 500 |
83513XX | 4.5 | 84 | 0.16 | 1.8 | 0.6 | 3 | 23 | 29 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Insulation | Plasticized PVC |
No. of Cores | Single core |
Test Voltage | 3 kV |
Standard | Bosch 598341 |
Standard type | DBL 6312 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | meter | |
83406XX* | 0.5 | 16 | 0.21 | 01/01/00 | 0.6 | 2.3 | 10 | 16 | 37.1 | 500 |
83408XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 21 | 24.7 | 500 |
83410XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 25 | 18.5 | 500 |
83413XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3 | 21 | 32 | 12.7 | 500 |
Product Details:
Temperature Range | - 40 deg C to +105 deg C |
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Insulation | Plasticized PVC |
No. of Cores | 1 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
83306XX * | 0.5 | 16 | 0.21 | 1 | 0.6 | 2.3 | 10 | 15 | 37.1 | 500 |
83308XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 19 | 24.7 | 500 |
83310XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 22 | 18.5 | 500 |
83313XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3 | 21 | 28 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +125 deg C (3000 Hours) |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class C |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Electron Beam Cross-Linked EVA (Ethylene Vinyl Acetate) |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath Thickness | Cable | Max. Conductor Resistance at 200 C | Standard Length | |||||
Nominal Cross- Section | No. of Core | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max | Weight Approx | |||||
mm2 | mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
FLR4G11Y | |||||||||||
8560502 | 0.35 | 2 | 19 | 0.16 | 0.8 | 0.35 | 0.5 | 4.8 | 29 | 54.5 | 500 |
8560602 | 0.5 | 2 | 28 | 0.16 | 1 | 0.35 | 0.55 | 5.2 | 36 | 40.1 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +105 deg C |
Test Voltage | 3 kV (r.m.s.) for cables |
Standard | ISO 6722, Class B |
Sheath | PVC, Lead-free Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath wall Thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max. | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
85508XX* | 0.75 | 24 | 0.21 | 1.2 | 0.3 | 0.3 | 2.7 | 20 | 20 | 24.7 | 500 |
85510XX | 1 | 32 | 0.21 | 1.35 | 0.3 | 0.3 | 2.9 | 23 | 24 | 18.5 | 500 |
85513XX | 1.5 | 30 | 0.26 | 1.7 | 0.3 | 0.3 | 3.2 | 29 | 30 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
No. Of Core | Single |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | Plasticized PVC |
Temperature Range | - 40 deg C to +105 deg C |
Standard | ISO 6722,Class B |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Sheath wall thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | ||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
85306XX* | 0.5 | 16 | 0.21 | 1 | 0.6 | 0.4 | 3.1 | 11 | 17 | 37.1 | 500 |
85308XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 0.4 | 3.3 | 14 | 22 | 24.7 | 500 |
85310XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 0.4 | 3.6 | 17 | 26 | 18.5 | 500 |
Product Details:
Brand | Siechem |
No. Of Core | Single |
Temperature Range | - 40C to +105C |
Test Voltage | 3kV |
Standard | ISO 6722, Class B |
Conductor | E-Cu ETP1 |
Insulation | PA (Polyamide) |
Product Details:
Brand | Siechem |
Temperature Rating | - 40 deg C to +105 deg C |
No. Of Core | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class B |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A87605XX* | 0.35 | 7 | 0.26 | 0.8 | 0.2 | 1.3 | 5 | 11 | 54.4 | 500 |
A87606XX | 0.5 | 19 | 0.19 | 1 | 0.22 | 1.6 | 6 | 14 | 37.1 | 500 |
A87608XX | 0.75 | 19 | 0.23 | 1.2 | 0.24 | 1.9 | 9 | 18 | 24.7 | 500 |
A87610XX | 1 | 19 | 0.26 | 1.35 | 0.24 | 2.1 | 11 | 22 | 18.5 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +110 deg C |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class C |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | FL11Y- TPE-U |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | FL91Y | FL11Y | ||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | Amps | ???/km | mtrs | |
85223XX* | 6 | 84 | 0.31 | 3.3 | 0.8 | 5 | 73 | 77 | 72 | 3.14 | 500 |
85227XX | 10 | 80 | 0.41 | 4.5 | 1 | 6.5 | 120 | 110 | 102 | 1.82 | 500 |
85228XX | 16 | 126 | 0.41 | 6.3 | 1 | 8.1 | 177 | 148 | 137 | 1.16 | 500 |
85230XX | 25 | 196 | 0.41 | 7.8 | 1.3 | 10.2 | 275 | 195 | 181 | 0.743 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +105 deg C |
Number of Cores | Single |
Test Voltage | 3kV (r.m.s.) for cables |
Standard | ISO 6722, Class B |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PA (Polyamide) |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A84005XX* | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 11 | 54.4 | 500 |
A84006XX | 0.5 | 16 | 0.21 | 1 | 0.2 | 1.6 | 6 | 14 | 37.1 | 500 |
A84008XX | 0.75 | 24 | 0.21 | 1.2 | 0.2 | 1.9 | 9 | 18 | 24.7 | 500 |
A84010XX | 1 | 32 | 0.21 | 1.35 | 0.25 | 2.1 | 12 | 22 | 18.5 | 500 |
A84013XX | 1.5 | 30 | 0.26 | 1.7 | 0.25 | 2.4 | 16 | 28 | 12.7 | 500 |
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +125 deg C |
Insulation | PVC |
Pouter Sheath | TPE-U |
Test Voltage | 3 kV |
Standard | ISO6722, Class B |
Siechem is India’s No.1 manufacturer & exporter of Automotive Wires & Cables. We manufacture almost all the types of automotive wires & cables that meet Japanese, Korean, American and European OEM specification. Some of the details are listed below :
Specification: JIS C 3406, JASO D 611, JASO D 608, ISO 6722, IS 2465, SAE J 1128, SAE J 1127, SAE J 1678, SAE J 1939/15 Volvo, Ford ES –AU5T -1A348, ES 91110-05, YPES-17-21-005, YPES-17-21-004, DIN 72551-6 & customized to your specification.
Types of Cable: AV, AV-f, AVS, AVS-f, AVSS, AVSS-f, AVSSH-f, AVSSX, AVSSX-f, AVX, AVX-f, AEX, AEX-f, AESSX, AESSX-f, CPE-FR, CPE –FR TW, EB, HEB, HDEB, GPT, HDT, TWP, TXL, GXL, SXL, STT, SGT, STX, SGX, WTA, WXC, RK, SK, RXKB, SXKB, R2, R4, Auto 85, Auto 85-TW, Auto 85-UTW, Auto 100, Auto 100 TW, Auto UTW, Auto 125, Auto 125-TW, Auto 125-UTW, Auto 150, Auto 150-TW, Auto 150-UTW, Auto 175, Auto 175-TW, Auto 175-UTW, ACW 150, Auto 125 P, Auto 125X-A & B, Auto 150 A-A & A-B, Auto 180 E-A & E-B, Auto 200G, Auto 200G AL, Auto 210F-A & B, Auto 260T, Auto 260 R-A & R-B, FLY, FLYW, FLYK, FLRYK, FLYWK, FLRYWK, FLRYW-A & B, FLRY T2 IR, FRLY T3 IR, FLR4Y-A & B, FL91Y-FL11Y, FLYY, FLRY-A,B&H, FLYOY-FLYKOY, FLRYDY, FLR4G11Y-FL4G11Y, FLR2X11Y, FLR31Y11Y, FLRY11Y, FLALRY, FLALRYW, FLR6Y-B, FLR12Y-A, ABS Sensor & CAN BUS UTP.
Features
Electron beam cross linked
Flame retardant and increased mechanical strength
Heat resistant and highly resistant against acids, petrol and diesel
Extra flexible conductors and super thin wall insulation for smaller diameter and lesser weight
High temperature & oil resistant cables for engine compartment
Applications
Low-tension electric wire for automobiles
ABS sensor cables with connectors
Used in all types of vehicles for starting, charging, lighting, signal and instrument panel circuits
Especially used for circuits requiring heat resistance properties
Product Details:
Temperature Range | - 40 deg C to +125 deg C |
Standard | SAE J1678 |
Conductor | Copper |
Insulation | XLPE |
Part Number | Size | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current carrying capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | ||||||
AWG | mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
A88383XX* | 22 | 0.35 | 7 | 0.25 | 0.76 | 0.2 | 1.35 | 4 | 53.9 | 12 | 500 |
A88382XX | 20 | 0.5 | 7 | 0.32 | 0.97 | 0.2 | 1.55 | 7 | 34.3 | 16 | 500 |
A88381XX | 18 | 0.8 | 19 | 0.23 | 1.17 | 0.2 | 1.75 | 8 | 23 | 21 | 500 |
A88380XX | 16 | 1.3 | 19 | 0.28 | 1.45 | 0.2 | 2.03 | 12 | 15.5 | 27 | 500 |
A88379XX | 14 | 2 | 19 | 0.36 | 1.8 | 0.2 | 2.39 | 19 | 9.44 | 37 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC |
Temperature Range | - 40 deg C to +100 deg C |
Standard | ISO 6722 Class B |
Test Voltage | 3 kV |
No. of Cores | Single core |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 20 C | Standard Length* | |||||
Nominal CrossSection | No. of Strands | ||||||||||
2mm | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | ||
*A83205XX | 0.35 | 7 | 0.27 | 0.9 | 0.25 | 1.4 | 5 | 10 | 54.4 | 2000 | |
A83206XX | 0.5 | 19 | 0.19 | 1.1 | 0.28 | 1.6 | 6 | 13 | 37.1 | 2000 | |
A83208XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 17 | 24.7 | 2000 | |
A83210XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 20 | 18.5 | 2000 | |
A83213XX | 1.5 | 19 | 0.33 | 1.8 | 0.3 | 2.4 | 17 | 26 | 12.7 | 2000 |
Product Details:
Brand | Siechem |
Insulation | PVC |
No. of Cores | Single core |
Standard | ISO 6722 Class B |
Temperature Range | - 40 deg C to +100 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness | Cable | Standard Length | ||||||
Nominal CrossSection | No. of Strands | Diameter of Single wire max. | Conductor Diameter max. | Overall Diameter Max. | Weight Approx. | Current Carrying Capacity | Max. Conductor Resistance 200 C | |||
2 mm | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
*A83306XX | 0.5 | 19 | 0.19 | 1.1 | 0.2 | 1.4 | 6 | 12 | 37.1 | 500 |
A83308XX | 0.75 | 19 | 0.24 | 1.3 | 0.2 | 01/01/60 | 8 | 16 | 24.7 | 500 |
A83310XX | 1 | 19 | 0.27 | 1.5 | 0.2 | 1.75 | 10 | 19 | 18.5 | 500 |
A83313XX | 1.5 | 19 | 0.33 | 1.8 | 0.2 | 2.1 | 15 | 25 | 12.7 | 500 |
Product Details:
Conductor Material | Copper |
Test Voltage, 1min | 3.5 kV AC / 8.4 kV DC |
Min. Bending Radius (fixed) | 4 X Cable dia |
Insulation | Sietherm 155 |
Insulation Colour | White |
Screening | Annealed Tinned Copper Conductor |
Outer Sheath | AX 150 |
Sheath Color | Orange |
Temperature Range | - 40 deg C to +150 deg C |
Voltage Rating (U0/U) | 600V AC / 1000V AC |
Part Number | Conductor Construction | Insulation Thickness Normal | Screen Wire Dia (Normal) | Outer Sheath Thickness (Normal) | Overall Diameter | Weight Approx. | Max. Conductor Resistance at 20°C | Standard Length* | ||
Size | No. of Strands | Diameter of Single wire Max. | ||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
A898130910 | 2.5 | 50 | 0.26 | 0.35 | 0.1 | 0.55 | 5.0 ± 0.3 | 50 | 7.6 | 500 |
A898190910 | 4 | 56 | 0.31 | 0.4 | 0.1 | 0.6 | 5.8 ± 0.3 | 70 | 4.71 | 500 |
A898230910 | 6 | 84 | 0.31 | 0.4 | 0.1 | 0.7 | 6.6 ± 0.3 | 100 | 3.14 | 500 |
A898270910 | 10 | 78 | 0.41 | 0.6 | 0.1 | 0.85 | 8.4 ± 0.3 | 155 | 1.82 | 500 |
A898280910 | 16 | 126 | 0.41 | 0.65 | 0.15 | 0.85 | 9.8 ± 0.3 | 230 | 1.16 | 500 |
Product Details:
Brand | Siechem |
Conductor | Copper |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Insulation | PVC |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A82305XX* | 0.35 | 7 | 0.27 | 0.9 | 0.25 | 1.3 | 5 | 9 | 54.4 | 2000 |
A82306XX | 0.5 | 19 | 0.19 | 1.1 | 0.28 | 1.6 | 6 | 11 | 37.1 | 2000 |
A82308XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 15 | 24.7 | 2000 |
A82310XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 18 | 18.5 | 2000 |
Product Details:
Brand | Siechem |
Insulated material | EBXL Special polymer sheathed |
Conductor Type | Soft-annealed electrolytic Copper construction |
Number Of Core | Single |
Temperature Range | - 40 deg C to +150 deg C |
Voltage | 60 V |
Scrape Abrasion | SA 2 as per volvo std 525-0001 |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | ||||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Max. | Overall Diameter | Weight Approx. | ||||||
Min. | Normal | Max. | |||||||||
mm2 | nos. | mm | mm | mm | mm | mm | mm | kg/km | Amps | kg/km | |
86005XX* | 0.35 | 7 | 0.27 | 0.8 | 0.35 | 1.2 | 1.3 | 1.4 | 5 | 13 | 52 |
86006XX | 0.5 | 19 | 0.19 | 1 | 0.35 | 1.4 | 1.5 | 1.6 | 7 | 16 | 37.1 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | Electron Beam Crossed Linked Polyolefin Class E |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max | Overall Diameter Weight Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | ???/km | mtrs | |
A84006XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 20 | 37.1 | 1000 |
A84008XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 25 | 24.7 | 1000 |
A84010XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 30 | 18.5 | 1000 |
A84013XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 38 | 12.7 | 1000 |