Siechem is India’s No.1 manufacturer & exporter of Battery Cables for the Automotive Industry. These cables are manufactured with Electrolytic grade high purity copper insulated with thermoplastic and elastomeric compound, electron beam irradiated and having thin wall and ultra thin wall thickness. Some of details are listed below.
Product Details:
Brand | Siechem |
Temperature Range | - 40 deg C to +80 deg C (3000 Hours) |
Conductor | Soft-annealed electrolytic Copper E-Cu ETP1 |
Insulation | PVC, Lead-free |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Max. Conductor Resistance at 20°C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Approx | Overall Diameter | Weight Approx. | ||||||
Nom | Max. | ||||||||||
mm2 | nos | mm | mm | mm | mm | mm | kg/mm | ???/km | Amps | mtrs | |
80106XX | 0.5 | 7 | 0.32 | 1 | 0.6 | 2.2 | 2.4 | 10 | 32.7 | 13 | 1000 |
80154XX | 0.85 | 11 | 0.32 | 1.2 | 0.6 | 2.4 | 2.6 | 13 | 20.8 | 17 | 1000 |
80112XX | 1.25 | 16 | 0.32 | 1.5 | 0.6 | 2.7 | 2.9 | 17 | 14.3 | 21 | 1000 |
Product Details:
Insulation | PVC, Lead-free |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
art Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx | ||||||
Nom. | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
83121XX* | 5 | 7/9/0.32 | 0.32 | 3.1 | 0.6 | 4.3 | 4.7 | 57 | 3.71 | 50 | 500 |
83126XX | 9 | 7/16/0.32 | 0.32 | 4.2 | 0.6 | 5.4 | 5.8 | 94 | 2.09 | 72 | 500 |
83127XX | 10 | 19/6/0.32 | 0.32 | 4.2 | 0.6 | 5.5 | 5.9 | 96 | 2.05 | 72 | 500 |
83155XX | 15 | 19/9/0.32 | 0.32 | 5.3 | 0.6 | 6.5 | 6.9 | 140 | 1.37 | 94 | 500 |
Product Details:
Color | Red |
Brand | Siechem |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Sheath Thickness | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | ||
85419XX* | 4 | 56 | 0.31 | 2.75 | 0.8 | 2 | 8.4 | 123 | 61 | 4.71 | 500 | |
85423XX | 6 | 84 | 0.31 | 3.3 | 0.8 | 2 | 9 | 149 | 77 | 3.1 | 500 | |
85427XX | 10 | 80 | 0.41 | 4.5 | 1 | 3 | 12.8 | 267 | 263 | 1.82 | 500 |
Product Details:
No. of Cores | Multi Core |
Conductor | Copper |
Temperature Range | - 80 deg C to +200 deg C |
Standard | ISO 6722 |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A87127XX* | 10 | 50 | 0.52 | 4.5 | 0.8 | 6.5 | 55 | 105 | 3.03 | 500 |
A87128XX | 16 | 78 | 0.52 | 5.8 | 0.8 | 8.3 | 76 | 141 | 1.93 | 500 |
A87130XX | 25 | 122 | 0.52 | 7.2 | 1.04 | 10.4 | 117 | 184 | 1.24 | 500 |
A87132XX | 35 | 172 | 0.52 | 8.5 | 1.04 | 11.6 | 152 | 226 | 0.878 | 500 |
A87134XX | 50 | 247 | 0.52 | 10.5 | 1.2 | 13.5 | 213 | 287 | 0.613 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max | Conductor Diameter Max | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A84105XX* | 0.35 | 7 | 0.27 | 0.9 | 0.3 | 1.3 | 5 | 13 | 54.4 | 2000 |
A84106XX | 0.5 | 19 | 0.19 | 1.1 | 0.3 | 1.6 | 6 | 18 | 37.1 | 2000 |
A84108XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 23 | 24.7 | 2000 |
A84110XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 28 | 18.5 | 2000 |
Product Details:
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Min. | Cable | Max. Conductor Resistance at 20°C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single Wire Max. | Conductor Diameter Max. | Overall Diameter Max. | Weight Approx. | |||||
Sq.mm | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
84105XX | 0.35 | 12 | 0.21 | 0.9 | 0.2 | 1.4 | 5 | 54.4 | 11 | 500 |
84106XX | 0.5 | 16 | 0.21 | 1.1 | 0.22 | 1.6 | 7 | 37.1 | 15 | 500 |
84108XX | 0.75 | 24 | 0.21 | 1.3 | 0.24 | 1.9 | 9 | 24.7 | 19 | 500 |
84110XX | 1 | 32 | 0.21 | 1.5 | 0.24 | 2.1 | 13 | 18.5 | 23 | 500 |
84113XX | 1.5 | 30 | 0.26 | 1.8 | 0.24 | 2.4 | 17 | 12.7 | 30 | 500 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Standard | ISO 6722 Class D |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Max. | Overall Diameter Max. | Weight Approx. | |||||
A81006XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 37.1 | 17 | 500 |
A81008XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 24.7 | 21 | 500 |
A81010XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 18.5 | 25 | 500 |
A81013XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 20 | 12.7 | 32 | 500 |
A81014XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 25 | 9.42 | 38 | 500 |
A81016XX | 2.5 | 37 | 0.29 | 2.2 | 0.7 | 3.6 | 31 | 7.6 | 44 | 500 |
Product Details:
Conductor | Soft-annealed electrolytic Copper |
Insulation | PVC, Lead-free |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Conductor resistance (200C) | Insulation Thickness | Cable Overall Diameter | Weight Apporx | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands/Dia of stands pcs/ pcs / mm | Outside Diameter Approx | Nominal | min | Nominal | min | |||||
mm2 | nos. | mm | mm | mm | mm | mm | mm | kg/km | Amps | mtrs | |
87014XX* | 2 | 37/0.26 | 1.8 | 9.5 | 0.6 | 0.48 | 3 | 3.4 | 25 | 27 | 500 |
87017XX | 3 | 58/0.26 | 2.3 | 6.06 | 0.7 | 0.56 | 3.7 | 4 | 36 | 36 | 500 |
87021XX | 5 | 7/9/0.32 | 3.1 | 3.71 | 0.8 | 0.64 | 4.7 | 5 | 60 | 50 | 500 |
Product Details:
Brand | Siechem |
Conductor | Stranded Copper |
No. of Cores | 1 |
Rated voltage | 100 V |
Standard | Volvo type |
Temperature Range | - 40 deg C to +70 deg C |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86806XX* | 0.5 | 16 | 0.21 | 1.1 | 0.6 | 2.6 | 9 | 39 | 8 | 500 |
86808XX | 0.75 | 24 | 0.21 | 1.3 | 0.6 | 2.8 | 11 | 26 | 10 | 500 |
86810XX | 1 | 32 | 0.21 | 1.5 | 0.6 | 3 | 13 | 19.5 | 12 | 500 |
86813XX | 1.5 | 30 | 0.26 | 1.8 | 0.7 | 3.5 | 19 | 13.3 | 16 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC, Lead-free |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +80 deg C |
Standard | SAE J1127 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
82461XX* | 13 | 133 | 0.36 | 4.83 | 1.09 | 7.8 | 141 | 1.4 | 93 | 500 |
82462XX | 19 | 133 | 0.46 | 6.09 | 1.12 | 9.5 | 205 | 0.94 | 119 | 500 |
82463XX | 32 | 133 | 0.57 | 7.67 | 1.12 | 11 | 332 | 0.56 | 161 | 500 |
82458XX | 40 | 259 | 0.46 | 8.49 | 1.12 | 12 | 407 | 0.42 | 190 | 500 |
Product Details:
Color | As per customer order |
Brand | Siechem |
YW | Heat hot pressure resistance |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
83406XX* | 0.5 | 16 | 0.21 | 01/01/00 | 0.6 | 2.3 | 10 | 16 | 37.1 | 500 |
83408XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 21 | 24.7 | 500 |
83410XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 25 | 18.5 | 500 |
83413XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3 | 21 | 32 | 12.7 | 500 |
Product Details:
Conductor | Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +175 deg C |
Standard | ISO 6722 Class E |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max | Overall Diameter Weight Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A84006XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 20 | 37.1 | 1000 |
A84008XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 25 | 24.7 | 1000 |
A84010XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 30 | 18.5 | 1000 |
A84013XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 38 | 12.7 | 1000 |
A84014XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 45 | 9.42 | 1000 |
Product Details:
Insulation | PVC, Lead-free |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Diameter of Single wire max. | Overall Diameter Max. | Weight Max. | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | ||
82606XX* | 0.5 | 16 | 0.21 | 1.1 | 0.6 | 2.3 | 10 | 37.1 | 17 | 500 | |
82608XX | 0.75 | 24 | 0.21 | 1.3 | 0.6 | 2.5 | 13 | 24.7 | 22 | 500 | |
82610XX | 1 | 32 | 0.21 | 1.8 | 0.6 | 2.7 | 16 | 18.5 | 26 | 500 | |
82613XX | 1.5 | 30 | 0.26 | 1.8 | 0.6 | 3 | 21 | 12.7 | 32 | 500 |
Product Details:
Brand | Siechem |
Number of Cores | Single |
Temperature Range | - 40 deg C to +80 deg C |
Standard | JASO D 611 |
Test Voltage | 1 kV |
Conductor Resistance | IEC 60228/BS 6360 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter | Weight Approx. | ||||||
Nom | Max. | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
83226XX* | 9 | 112 | 0.32 | 4.2 | 1 | 6.2 | 6.5 | 102 | 2.09 | 73 | 500 |
83255XX | 15 | 171 | 0.32 | 5.3 | 1.1 | 7.5 | 8 | 152 | 1.37 | 95 | 500 |
83256XX | 20 | 247 | 0.32 | 6.5 | 1.1 | 8.7 | 9.3 | 210 | 0.966 | 120 | 500 |
83257XX | 30 | 361 | 0.32 | 7.8 | 1.4 | 10.6 | 11.3 | 311 | 0.647 | 150 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | Electron Beam Cross-Linked Polyolefin |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +150 deg C |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A81405XX* | 0.35 | 7 | 0.27 | 0.9 | 0.35 | 1.3 | 5 | 12 | 54.4 | 2000 |
A81406XX | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.6 | 6 | 16 | 37.1 | 2000 |
A81408XX | 0.75 | 19 | 0.24 | 1.3 | 0.35 | 1.9 | 9 | 22 | 24.7 | 2000 |
A81410XX | 1 | 19 | 0.27 | 1.5 | 0.35 | 2.1 | 12 | 26 | 18.5 | 2000 |
Product Details:
Conductor Material | Soft / annealed Plain Copper |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +125 deg C |
Standard | ISO 6722 Class C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Max. Conductor Resistance at 200C | Current Carrying capacity | StandardLength* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
A81105XX** | 0.35 | 7 | 0.27 | 0.9 | 0.3 | 1.4 | 5 | 54.4 | 12 | 2000 |
A81106XX | 0.5 | 19 | 0.19 | 1.1 | 0.3 | 1.6 | 6 | 37.1 | 15 | 2000 |
A81108XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 24.7 | 20 | 2000 |
A81110XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 18.5 | 24 | 2000 |
Product Details:
Conductor Material | Soft / annealed Plain Copper |
Insulation | PVC Compound |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | ISO 6722 Class B |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
A83106XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 37.1 | 14 | 1000 |
A83108XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 24.7 | 18 | 1000 |
A83110XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 18.5 | 22 | 1000 |
A83113XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 20 | 12.7 | 28 | 1000 |
A83114XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 9.42 | 33 | 1000 |
Product Details:
Conductor Material | Copper |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +150 deg C |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A81405XX* | 0.35 | 7 | 0.27 | 0.9 | 0.35 | 1.3 | 5 | 12 | 54.4 | 2000 |
A81406XX | 0.5 | 19 | 0.19 | 1.1 | 0.35 | 1.6 | 6 | 16 | 37.1 | 2000 |
A81408XX | 0.75 | 19 | 0.24 | 1.3 | 0.35 | 1.9 | 9 | 22 | 24.7 | 2000 |
A81410XX | 1 | 19 | 0.27 | 1.5 | 0.35 | 2.1 | 12 | 26 | 18.5 | 2000 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A82206XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 13 | 37.1 | 1000 |
A82208XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 16 | 24.7 | 1000 |
A82210XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 19 | 18.5 | 1000 |
A82213XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 20 | 25 | 12.7 | 1000 |
A82214XX | 2 | 19 | 0.38 | 2 | 0.6 | 3.3 | 26 | 29 | 9.42 | 1000 |
Product Details:
Conductor | Soft / annealed Plain Copper |
Insulation | PVC |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter max | Overall Diameter Max. | Weight Approx | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
A82305XX* | 0.35 | 7 | 0.27 | 0.9 | 0.25 | 1.3 | 5 | 9 | 54.4 | 2000 |
A82306XX | 0.5 | 19 | 0.19 | 1.1 | 0.28 | 1.6 | 6 | 11 | 37.1 | 2000 |
A82308XX | 0.75 | 19 | 0.24 | 1.3 | 0.3 | 1.9 | 9 | 15 | 24.7 | 2000 |
A82310XX | 1 | 19 | 0.27 | 1.5 | 0.3 | 2.1 | 11 | 18 | 18.5 | 2000 |
A82313XX | 1.5 | 19 | 0.33 | 1.8 | 0.3 | 2.4 | 16 | 23 | 12.7 | 2000 |
Product Details:
Insulation | Lead-free PVC |
Temperature Range | - 40 deg C to +70 deg C |
Test Voltage | 3 kV |
Conductor Resistance | IS 8130 |
Standard | IS 2465 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 20°C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single Wire Max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
Sq.mm | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
83028XX | 16 | 126 | 0.4 | 5.7 | 1 | 8.1 | 171 | 1.21 | 90 | 500 |
83030XX | 25 | 196 | 0.4 | 7.1 | 1.2 | 10 | 263 | 0.78 | 118 | 500 |
83032XX | 35 | 276 | 0.4 | 8.5 | 1.2 | 11.4 | 357 | 0.554 | 146 | 500 |
Product Details:
Insulation | Sietherm 155 |
Min. Bending Radius (fixed) | 4 X Cable diameter |
Insulation Colour | White |
Screening | Annealed Tinned Copper Conductor |
Outer Sheath | AX 150 |
Sheath Colour | Orange |
Temperature Range | - 40 deg C to +150 deg C |
Voltage Rating (U0/U) | 600 V AC / 1000 V AC |
Standard | ISO 6722 Class D |
Test Voltage | 3.5 kV AC / 8.4 kV DC |
Part Number | Conductor Construction | Insulation Thickness Normal | Screen Wire Dia (Normal) | Outer Sheath Thickness (Normal) | Overall Diameter | Weight Approx. | Max. Conductor Resistance at 20°C | Standard Length* | ||
Size | No. of Strands | Diameter of Single wire Max. | ||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
A898130910 | 2.5 | 50 | 0.26 | 0.35 | 0.1 | 0.55 | 5.0 ± 0.3 | 50 | 7.6 | 500 |
A898190910 | 4 | 56 | 0.31 | 0.4 | 0.1 | 0.6 | 5.8 ± 0.3 | 70 | 4.71 | 500 |
A898230910 | 6 | 84 | 0.31 | 0.4 | 0.1 | 0.7 | 6.6 ± 0.3 | 100 | 3.14 | 500 |
A898270910 | 10 | 78 | 0.41 | 0.6 | 0.1 | 0.85 | 8.4 ± 0.3 | 155 | 1.82 | 500 |
A898280910 | 16 | 126 | 0.41 | 0.65 | 0.15 | 0.85 | 9.8 ± 0.3 | 230 | 1.16 | 500 |
Product Details:
Conductor | Copper |
Insulation | Plasticized PVC |
Temperature Range | - 40 deg C to +125 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
83705XX* | 0.35 | 12 | 0.21. | 0.9 | 0.2 | 1.4 | 5 | 12 | 54.4 | 500 |
83706XX | 0.5 | 16 | 0.21 | 1 | 0.22 | 1.6 | 6 | 15 | 37.1 | 500 |
83708XX | 0.75 | 24 | 0.21 | 1.2 | 0.24 | 1.9 | 9 | 19 | 24.7 | 500 |
83710XX | 1 | 32 | 0.21 | 1.35 | 0.24 | 2.1 | 12 | 23 | 18.5 | 500 |
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | 1 |
Insulation | PVC |
Temperature Range | - 40 deg C to +85 deg C |
Standard | ISO 6722 Class A |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
83506XX* | 0.5 | 28 | 0.16 | 1.1 | 0.6 | 2.3 | 11 | 15 | 37.7 | 500 |
83508XX | 0.75 | 42 | 0.16 | 1.3 | 0.6 | 2.5 | 14 | 19 | 25.1 | 500 |
83510XX | 1 | 57 | 0.16 | 1.5 | 0.6 | 2.7 | 17 | 23 | 18.8 | 500 |
83513XX | 4.5 | 84 | 0.16 | 1.8 | 0.6 | 3 | 23 | 29 | 12.7 | 500 |
83516XX | 2 | 140 | 0.16 | 2.3 | 0.7 | 3.9 | 36 | 40 | 7.54 | 500 |
Product Details:
Conductor | Copper |
Insulation | Plasticized PVC |
Temperature Range | - 40 deg C to +105 deg C |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg/km | mtrs | |
83306XX * | 0.5 | 16 | 0.21 | 1 | 0.6 | 2.3 | 10 | 15 | 37.1 | 500 |
83308XX | 0.75 | 24 | 0.21 | 1.2 | 0.6 | 2.5 | 13 | 19 | 24.7 | 500 |
83310XX | 1 | 32 | 0.21 | 1.35 | 0.6 | 2.7 | 16 | 22 | 18.5 | 500 |
83313XX | 1.5 | 30 | 0.26 | 1.7 | 0.6 | 3 | 21 | 28 | 12.7 | 500 |
Product Details:
Conductor Material | Copper |
Insulation | Class 2 |
No. of Cores | 1 |
Temperature Range | - 40 deg C to +100 deg C |
Standard | Volvo type |
Rated Voltage | 100 V |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Nom | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | kg/km | Amps | mtrs | |
86505XX* | 0.35 | 12 | 0.21 | 0.9 | 0.3 | 1.5 | 6 | 54.4 | 5 | 100 |
86506XX | 0.5 | 16 | 0.21 | 1.1 | 0.35 | 1.9 | 8 | 39 | 8 | 100 |
86508XX | 0.75 | 24 | 0.21 | 1.3 | 0.35 | 2.1 | 10 | 26 | 10 | 100 |
86510XX | 1 | 32 | 0.21 | 1.5 | 0.35 | 2.3 | 12 | 19.5 | 12 | 100 |
Product Details:
Temperature Range | - 40 deg C to +100 deg C |
Standard | Volvo type |
Rated Voltage | 750 V |
Sheath | PVC Compound type TI 3 |
Conductor | IEC 60228 |
Insulation | XLPE |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Nominal Thickness of sheath | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Overall Diameter | Weight Approx | |||||||
Nom | Max | ||||||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86708XX* | 16 | 112 | 0.41 | 0.7 | 0.8 | 8.3 | 8.5 | 180 | 1.21 | 76 | 500 |
86710XX | 25 | 183 | 0.41 | 0.7 | 0.8 | 9.7 | 9.9 | 280 | 0.78 | 96 | 500 |
86713XX | 35 | 259 | 0.41 | 0.7 | 0.8 | 10.9 | 11.2 | 360 | 0.554 | 120 | 500 |
86716XX | 50 | 382 | 0.41 | 0.8 | 1 | 13 | 13.4 | 510 | 0.386 | 155 | 500 |
Product Details:
Color | Black |
Conductor | IEC 60228 |
Insulation | XLPE |
Sheath | PVC Compound type TI 3 |
Temperature Range | - 40 deg C to +90 deg C |
Standard | Volvo type |
Rated Voltage | 750 V |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Nominal Thickness of sheath | Cable | Max. Conductor Resistance at 200C | Current Carrying Capacity | Standard Length* | |||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Overall Diameter Nom | Weight Approx. | ||||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | Amps | mtrs | |
86406XX* | 10 | 74 | 0.41 | 0.7 | 0.8 | 7.3 | 121 | 1.78 | 60 | 500 |
86408XX | 16 | 118 | 0.41 | 0.7 | 0.8 | 8.3 | 180 | 1.21 | 76 | 500 |
86410XX | 25 | 183 | 0.41 | 0.7 | 0.8 | 9.7 | 280 | 0.78 | 96 | 500 |
86413XX | 35 | 259 | 0.41 | 0.7 | 0.8 | 10.9 | 360 | 0.554 | 120 | 500 |
86416XX | 50 | 382 | 0.41 | 0.8 | 1 | 13 | 510 | 0.386 | 155 | 500 |
Product Details:
Color | Black |
Conductor material | Copper |
Insulation | PVC |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +125 deg C |
Standard | Volvo type |
Rated Voltage | 50 V |
Part Number | Conductor Construction | Insulation Wall Thickness Normal | Cable | Max. Conductor Resistance at 200 C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire max. | Conductor Diameter Normal | Overall Diameter Max | Weight Approx. | ||||
mm2 | nos. | mm | mm | mm | mm | kg/km | ???/km | mtrs | |
86928XX* | 16 | 536 | 0.2 | 5.5 | 1 | 7.5 | 177 | 1.16 | 1000 |
86930XX | 25 | 826 | 0.2 | 9.7 | 1.3 | 9.7 | 275 | 0.74 | 1000 |
86932XX | 35 | 1184 | 0.2 | 11.2 | 1.3 | 11.2 | 369 | 0.527 | 1000 |
86934XX | 50 | 1144 | 0.23 | 13 | 1.5 | 13 | 525 | 0.368 | 500 |
Product Details:
Length | 12mm |
Temperature Rating | -40 deg C to +260 deg C |
Power/Voltage | 600 V |
Brand | Siechem |
Conductor | Soft-annealed electrolytic copper |
Insulation | EBXL-XLPO, EBXL-PVC, PVC, PE, TPE, PFA & PTFE |
Siechem is India’s No.1 manufacturer & exporter of Battery Cables for the Automotive Industry. These cables are manufactured with Electrolytic grade high purity copper insulated with thermoplastic and elastomeric compound, electron beam irradiated and having thin wall and ultra thin wall thickness. Some of details are listed below.
Types of Cable: AV, Auto 100, Auto 125-TW, Auto 125, Auto 125P, Auto 150, Auto 150TW, Auto 175, Auto 175 TW, Auto 200G AL, Auto 200G, Auto 85, Auto 85 TW, CPE-FR, EB, FLRYW-B, FLY, FLYK, FLYOY-FLYKOY, FLYW, HDEB, Battery Cable, HEB, R2, RK, RXKB, SGT, SGX, SK, STT, STX & SXKB.
Features:
Applications:
Product Construction:
Approvals:
Leading Customers:
Product Details:
Conductor | Soft / annealed Plain Copper |
No. of Cores | Single core |
Temperature Range | - 40 deg C to +125 deg C |
Standard | ISO 6722 Class D |
Test Voltage | 3 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Current Carrying Capacity | Max. Conductor Resistance at 200C | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single wire Max. | Conductor Diameter Max. | Overall Diameter Max | Weight Approx. | |||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | kg /km | mtrs | |
A81306XX* | 0.5 | 19 | 0.19 | 1.1 | 0.6 | 2.3 | 10 | 18 | 37.1 | 1000 |
A81308XX | 0.75 | 19 | 0.24 | 1.3 | 0.6 | 2.5 | 13 | 23 | 24.7 | 1000 |
A81310XX | 1 | 19 | 0.27 | 1.5 | 0.6 | 2.7 | 15 | 28 | 18.5 | 1000 |
A81313XX | 1.5 | 19 | 0.33 | 1.8 | 0.6 | 3 | 21 | 35 | 12.7 | 1000 |
Product Details:
Brand | Siechem |
Conductor | Soft-annealed electrolytic copper E-Cu ETP1 |
Insulation | Electron beam cross-linked polyolefin |
Standard | SAE J1127 |
Temperature Range | - 40 deg C to +120 deg C |
Test Voltage | 1 kV |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 20°C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single Wire Max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
Sq.mm | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
82261XX | 13 | 133 | 0.36 | 4.83 | 1.09 | 7.8 | 147 | 1.4 | 126 | 500 |
82262XX | 19 | 133 | 0.46 | 6.09 | 1.12 | 9.5 | 230 | 0.94 | 161 | 500 |
82263XX | 32 | 133 | 0.57 | 7.67 | 1.12 | 11 | 341 | 0.56 | 217 | 500 |
82258XX | 40 | 259 | 0.46 | 8.49 | 1.12 | 12 | 421 | 0.42 | 254 | 500 |
Product Details:
Conductor | Copper |
Temperature Range | - 40 deg C to +120 deg C |
Test Voltage | 1 kV |
Standard | SAE J1127 |
Part Number | Conductor Construction | Insulation Wall Thickness Nom. | Cable | Max. Conductor Resistance at 20°C | Current Carrying Capacity | Standard Length* | ||||
Nominal Cross- Section | No. of Strands | Diameter of Single Wire Max. | Conductor Diameter Nom. | Overall Diameter Max. | Weight Approx. | |||||
Sq.mm | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
82561XX | 13 | 133 | 0.36 | 4.83 | 1.52 | 8.6 | 166 | 1.4 | 93 | 500 |
82562XX | 19 | 133 | 0.46 | 6.09 | 1.65 | 10.5 | 257 | 0.94 | 119 | 500 |
82563XX | 32 | 133 | 0.57 | 7.67 | 1.65 | 12 | 373 | 0.56 | 161 | 500 |
82558XX | 40 | 259 | 0.46 | 8.49 | 1.65 | 13 | 455 | 0.42 | 190 | 500 |