Siechem is leading manufacturer & exporter of Flexible Cables. These cables are manufactured with EC grade copper having PVC or Rubber (Elastomeric compound) insulation & sheathed with excellent Zero Halogen, HR, FR & FRLS properties.
Product Details:
Conductor Material | Copper |
Insulation | PVC Compound |
Temperature Range (Flexible) | - 25 C to +80 C |
Temperature Range(Fixed) | - 40 C to +80 C |
Test Voltage | 2.5 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 6 x Cable Diameter |
Bending Radius (Static) | 4 x Cable Diameter |
Rated Voltage: (U /U) | 300/500 V |
Core Material | PVC |
Part Number | Conductor | Thickness of Insulation (Nom.) | Thickness of inner Sheath (Nom.) | Thickness of outer Sheath (Nom.) | Overall diameter (Nom.) | |
Area | Number and dia. of Wire | |||||
Sq.mm | No./mm | mm | mm | mm | mm | |
1781303 | 3C x 1.5 | 30/0.25 | 0.6 | 1 | 1.2 | 10.8 |
1781603 | 3C x 2.5 | 50/0.25 | 0.7 | 1 | 1.2 | 13.2 |
1781903 | 3C x 4 | 56/0.30 | 0.8 | 1 | 1.2 | 14.2 |
1782303 | 3C x 6 | 84/0.30 | 0.8 | 1 | 1.4 | 16.5 |
1782703 | 3C x 10 | 140/0.30 | 1 | 1 | 1.4 | 19.1 |
1782803 | 3C x 16 | 126/0.4 | 1 | 1 | 1.4 | 23.5 |
1783003 | 3C x 25 | 196/0.4 | 1.2 | 1 | 1.6 | 28.5 |
1783203 | 3C x 35 | 276/0.4 | 1.2 | 1 | 2 | 30.5 |
Product Details:
Conductor Material | Copper |
Voltage | 600/1000 V |
Insulation | PVC Compound |
Temperature Range (Flexible) | - 25 C to +80 C |
Temperature Range (Fixed) | - 40 C to +80 C |
Test Voltage | 2.5 kV |
Protective Conductor(PC) | G-With green/yellow |
Bending Radius (Flexing) | 6 x Cable Diameter |
Bending Radius (Static) | 4 x Cable Diameter |
Rated Voltage(U /U) | 300/500 V |
Part Number | Conductor | Insulation | Sheath | Conductor Resistance @ 20°C (Max.) | Current Carrying Capacity @ 40°C | ||
Area (Nom.) | No/dia. of strands | Thickness (Nom.) | Thickness (Nom.) | Overall dimensions (Approx.) (W x T) | |||
Sq.mm | No./mm | mm | mm | mm | Ohms/Km | Amps | |
1391303 | 1.5 | 22/0.3 | 0.6 | 0.9 | 11.0 x 5.0 | 12.1 | 16 |
1391603 | 2.5 | 36/0.3 | 0.7 | 1 | 13.0 x 6.0 | 7.41 | 22 |
1391903 | 4 | 56/0.3 | 0.8 | 1 | 15.3 x 6.7 | 4.95 | 29 |
1392303 | 6 | 84/0.3 | 1 | 1.15 | 18.6 x 8.0 | 3.3 | 37 |
1392703 | 10 | 80/0.4 | 1 | 1.4 | 23.4 x 10.0 | 1.91 | 51 |
1392803 | 16 | 126/0.4 | 1 | 1.4 | 28.0 x 11.4 | 1.21 | 68 |
1393003 | 25 | 196/0.4 | 1.2 | 2 | 35.4 x 14.8 | 0.78 | 86 |
Product Details:
Number of Core | 1 |
Conductor Material | Copper |
Insulation Material | PVC |
Braiding | Tinned Copper wires |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Sheath | Transparent Special PVC Material |
Temperature Range (Flexible) | - 50 C to +700 C |
Temperature Range (Fixed) | - 400 C to +800 C |
Test Voltage | 4 kV |
Protective Conductor(PC) | G- With green/yellow PC |
Bending Radius (Flexing) | 20 x Cable Diameter |
Bending Radius (Static) | 6 x Cable Diameter |
Rated Voltage | 300/500 V |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Total Weight Kg/Km approx. |
6030602 | 2C x 0.5 | 7.4 | 41 | 88 |
6030603G | 3 G 0.5 | 8.4 | 46 | 109 |
6030604G | 4 G 0.5 | 8.9 | 55 | 126 |
6030605G | 5 G 0.5 | 9.5 | 66 | 148 |
6030607G | 7 G 0.5 | 10.1 | 80 | 162 |
6030802G | 2C x 0.75 | 8.8 | 46 | 117 |
6030803G | 3 G 0.75 | 9.2 | 57 | 134 |
6030804G | 4 G 0.75 | 9.9 | 64 | 153 |
6030805G | 5 G 0.75 | 10.6 | 77 | 179 |
6030807G | 7 G 0.75 | 11.4 | 102 | 203 |
Product Details:
Number of Core | 1 |
Insulation Material | PVC |
Cable Conductor | Copper |
Brand | Siechem |
Temperature Range | - 300 C to +700 C |
Test Voltage | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 15 x Cable Diameter |
Bending Radius (Static) | 4 x Cable Diameter |
Rated Voltage(U /U) | 600/1000V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6060602 | 2C x 0 .5 | 4.9 | 9.6 | 36 |
6060603G | 3G x 0 .5 | 5.16 | 1 4 .4 | 43 |
60606 03 | 3C x 0 .5 | 5.2 | 1 4 .4 | 43 |
6060604G | 4G x 0 .5 | 5.7 | 1 9 .0 | 53 |
6060604 | 4C x 0 .5 | 5.7 | 1 9 .0 | 53 |
6060605G | 5G x 0 .5 | 6.2 | 2 4 .0 | 65 |
Product Details:
Conductor Material | Copper |
Insulation | PVC Compound |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Sheath | PVC Material |
Temperature Range (Flexible) | - 50 C to +700 C |
Temperature Range (Fixed) | - 400 C to +800 C |
Test Voltage | 4 kV |
Protective Conductor(PC) | G- With green/yellow PC |
Bending Radius (Flexing) | 15 x Cable Diameter |
Bending Radius (Static) | 4 x Cable Diameter |
Rated Voltage | 300/500 V |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Total Weight Kg/Km approx. |
6010602 | 2C x 0.5 | 5.5 | 9.6 | 43 |
6010603G | 3 G 0.5 | 5.8 | 14.4 | 51 |
6010603 | 3C x 0.5 | 5.8 | 15 | 51 |
6010604G | 4 G 0.5 | 6.4 | 19.2 | 62 |
6010604 | 4C x 0.5 | 6.4 | 19.2 | 62 |
6010605G | 5 G 0.5 | 7 | 24 | 76 |
6010605 | 5C x 0.5 | 7 | 24 | 76 |
6010606G | 6 G 0.5 | 7.6 | 29 | 90 |
6010607G | 7 G 0.5 | 7.6 | 33.6 | 83 |
6010608G | 8 G 0.5 | 8.3 | 38.4 | 91 |
6010610G | 10 G 0.5 | 9.7 | 48 | 116 |
6010612G | 12 G 0.5 | 9.9 | 58 | 131 |
Product Details:
Number of Core | 1 |
Insulation Material | PVC |
Conductor Material | Copper |
Temperature Range (Flexible) | - 300 C to +700 C |
Fixed Installation | - 400 C to +800 C |
Test Voltage | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Flexing | 15 x Cable Diameter |
Static | 4 x Cable Diameter |
Rated Voltage | 600/1000 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6050602 | 2C x 0.5 | 6.5 | 9.6 | 57 |
6050603G | 3 G 0.5 | 6.8 | 14.4 | 66 |
6050604G | 4 G 0.5 | 7.4 | 19.2 | 80 |
6050605G | 5 G 0.5 | 8.1 | 24 | 96 |
6050607G | 7 G 0.5 | 8.8 | 34 | 117 |
6050612G | 12 G 0.5 | 11.5 | 58 | 201 |
6051002 | 2C x 1 | 7.6 | 19.2 | 83 |
Product Details:
Conductor | Strands of bare Copper wires |
Insulation | Electron Beam Cross Linked Polyolefin (Halogen Free) |
Temperature Range (Flexible) | - 50 C to +1250 C |
Temperature Range(Fixed) | -250 C to +1250 C |
Test Voltage | 6 kV at 50 Hz, 5 min |
Bending Radius (Flexing) | 10 x Cable Diameter |
Static | 6 x Cable Diameter |
Rated Voltage (U /U) | 1.8/3 kV |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6411304 | 1.5 | 6.99 | 14.4 | 67.55 |
6411604 | 2.5 | 7.45 | 24 | 82.79 |
6411904 | 4 | 8.8 | 38 | 119.18 |
6412304 | 6 | 9.39 | 58 | 147.51 |
6412704 | 10 | 10.72 | 96 | 208.08 |
6412804 | 16 | 11.81 | 154 | 282.43 |
6413004 | 25 | 13.7 | 240 | 405.73 |
6413204 | 35 | 14.91 | 336 | 521.46 |
6413404 | 50 | 16.43 | 480 | 690.26 |
Product Details:
Brand | Siechem |
Length | 7.1mm |
Power/Voltage | 750 kv |
Test voltage | 2kV |
Conductor resistance | EN 60228 |
Working voltage | 450/750 V |
Max Operating temperature | 900C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max Conductor resistance at 200C | Weight approx. | |||
Single layer | Dual layers | Minimum | Maximum | ||||||||
Inner layers | Outer layer | ||||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | mm | mm | Ω/Km | Kg/Km | |
A02313XX | 1 | 1.5 | 1.6 | 0.8 | 1.4 | – | – | 5.7 | 7.1 | 13.3 | 66 |
A02316XX | 1 | 2.5 | 2 | 0.9 | 1.4 | – | – | 6.3 | 7.9 | 7.98 | 84 |
Product Details:
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 450/750 V |
Max. Operating temperature | 600 C |
Part Number | Conductor Construction | Insulation Thickness Nom. | Core diameter | Core diameter | Cable diameter | |||||
Nominal Cross- Section | No. of Strands | Strand dia max. | Conductor Diameter Nom. | Min | Max | Min. | Max. | |||
mm2/AWG | Nos. | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 mm2 | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 mm2 | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Brand | Siechem |
Conductor | Soft / annealed Plain Copper |
Conductor resistance | EN 60228 |
Max. Operating temperature | 1100 C |
Test voltage | 2 kV |
Working voltage(u /u) | 300/500 V |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter (Height X Width ) | Max Conductor resistance at 200C | Weight approx. | |||||||||
Minimum | Maximum | ||||||||||||||||
mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | ||||||||||
A0280802 | 2 | 0.75 | 1.14 | 0.6 | 0.8 | 3.7 X 6.0 | 4.7 X 7.4 | 26 | 58 | ||||||||
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering | |||||||||||||||||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 | Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 | White – 09 | Orange – 10 | Violet – 11 |
Product Details:
Insulation Material | PVC |
Conductor Type | Solid |
Number of Core | 2 Core |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 1100 C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max resistance at 200C. | Weight approx. | |
Minimum | Maximum | ||||||||
Nos | mm2 | mm | mm | mm | mm | mm | Ω/Km | Kg/Km | |
A0270802 | 2 | 0.75 | 1.14 | 0.6 | 0.8 | 5.7 | 7.4 | 26 | 76 |
A0271002 | 2 | 1 | 1.32 | 0.6 | 0.9 | 6.1 | 8 | 19.5 | 89 |
A0271302 | 2 | 1.5 | 1.6 | 0.8 | 1 | 7.6 | 9.8 | 13.3 | 126 |
A0271602 | 2 | 2.5 | 2 | 0.9 | 1.1 | 9 | 11.6 | 7.98 | 174 |
Product Details:
Brand | Siechem |
Conductor | Copper |
Conductor resistance | EN 60228 |
Max. Operating temperature | 900 C |
Test voltage | 2 kV |
Working voltage(u /u) | 300/500 V |
Part Number | Numberof Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max conductor resistance | Weight | |
Minimum | Maximum | approx. | |||||||
mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | ||
A0220802 | 2 | 0.75 | 1.14 | 0.6 | 0.8 | 5.7 | 7.4 | 26 | 66 |
A0221002 | 2 | 1 | 1.32 | 0.6 | 0.9 | 6.1 | 8 | 19.5 | 78 |
A0220803 | 3 | 0.75 | 1.14 | 0.8 | 0.9 | 6.2 | 8.1 | 26 | 81 |
Product Details:
Brand | Siechem |
Conductor | Copper |
Conductor resistance | EN 60228 |
Max. Operating temperature | 700 deg C |
Test voltage | 2 kV |
Working voltage(u /u) | 300/300 V |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter (Height x Width) | Max. Conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0310602 | 2 | 0.5 | 0.93 | 0.5 | 0.6 | 3.0 X 4.9 | 3.7 X 5.9 | 39 | 36 |
A0310802 | 2 | 0.75 | 1.14 | 0.5 | 0.6 | 3.2 X 5.2 | 3.8 X 6.3 | 26 | 43 |
Product Details:
Conductor | Copper |
Insulation | PVC |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage | 300/500 V |
Max. Operating temperature | 900 C |
Max short circuit temp | 150 C |
Part Number | Conductor Construction | Insulation Thickness Nom. | Core diameter | Core diameter | Cable diameter | |||||
Nominal Cross- Section | No. of Strands | Strand dia max. | Conductor Diameter Nom. | Min | Max | Min. | Max. | |||
mm2/AWG | Nos. | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 mm2 | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 mm2 | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Conductor | Copper |
Insulation | PVC |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/300 V |
Max. Operating temperature | 900 C |
Part Number | Conductor Construction | Insulation Thickness Nom. | Core diameter | Core diameter | Cable diameter | |||||
Nominal Cross- Section | No. of Strands | Strand dia max. | Conductor Diameter Nom. | Min | Max | Min. | Max. | |||
mm2/AWG | Nos. | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 mm2 | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 mm2 | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Conductor | Copper |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Insulation | Halogen Free Compound |
Temperature Range (Flexible) | - 300 C to +700 C |
Fixed | - 400 C to +800 C |
Voltage for Testing | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 15 x Cable Diameter |
Static | 4 x Cable Diameter |
Rated Voltage(U /U) | 450/750 V |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
61306 02 | 2C x0.5 | 4.9 | 9.6 | 35.54 |
6130603G | 3G 0.5 | 5.2 | 14.4 | 43.04 |
6130603 | 3C x0.5 | 5.2 | 14.4 | 43.04 |
6130604G | 4G 0.5 | 5.9 | 19.2 | 56.01 |
6130604 | 4C x0.5 | 5.9 | 19.2 | 56.01 |
6130605G | 5G 0.5 | 6.4 | 24 | 67.68 |
6130605 | 5C x0.5 | 6.4 | 24 | 67.68 |
6130607G | 7G 0.5 | 7 | 33.6 | 84.52 |
613062G | 12G 0.5 | 9.1 | 57.6 | 155.45 |
6130802 | 2C x0.75 | 5.9 | 14.4 | 52.28 |
6130803G | 3G 0.75 | 6.3 | 21.6 | 63.4 |
6130803 | 3C x0.75 | 6.3 | 21.6 | 63.4 |
Product Details:
Conductor | Finely Stranded Bare Copper Wires |
Bending Radius (Static) | 4 x Cable Diameter |
Rated Voltage(U /U) | 300/500 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Insulation | PVC Compound |
Outer Sheath | PVC Material and with Orange Color |
Core identification | Orange Colored cores |
Temperature Range | - 50 deg C to +700 deg C |
Fixed Installation | - 400 deg C to +800 deg C |
Voltage for Testing | 4 kV |
Protective Conductor (PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 15 x Cable Diameter |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6121002 | 2Cx1 | 5.62 | 19.19 | 52.91 |
6121003G | 3G1 | 5.99 | 28.78 | 65.81 |
6121003 | 3Cx1 | 5.99 | 28.78 | 65.81 |
6121004G | 4G1 | 6.59 | 38.38 | 82.55 |
6121004 | 4Cx1 | 6.59 | 38.38 | 82.55 |
6121005G | 5G1 | 7.24 | 47.97 | 100.94 |
6121302 | 2Cx1.5 | 6.18 | 28.99 | 68.67 |
Product Details:
Conductor Material | Copper |
Rated Voltage: (U /U) | 300/500 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Insulation | PVC compound |
Braiding | Tinned Copper Wire |
Temperature Range (Flexible) | - 50 C to +700 C |
Fixed Installation | - 400 deg C to +800 deg C |
Voltage for Testing | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 20 x Cable Diameter |
Bending Radius (Static) | 6 x Cable Diameter |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6090602 | 2C x0.5 | 8.11 | 41.04 | 99.62 |
6090603G | 3G 0.5 | 8.45 | 45.45 | 108.6 |
6090603 | 3C x0.5 | 8.45 | 45.45 | 108.6 |
6090604G | 4G 0.5 | 9 | 54.98 | 126.8 |
6090604 | 4C x0.5 | 9 | 54.98 | 126.8 |
6090605G | 5G 0.5 | 9.6 | 61.39 | 143.46 |
6090605 | 5C x0.5 | 9.6 | 61.39 | 143.46 |
6090607G | 7G 0.5 | 10.24 | 80.52 | 173.47 |
6090607 | 7C x0.5 | 10.24 | 80.52 | 173.47 |
Product Details:
Conductor | Finely Stranded Bare Copper Wires |
Static | 6 x Cable Diameter |
Rated Voltage: (U /U) | 600/1000 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Insulation | Black PVC Compound |
Braiding | Tinned Copper Wire |
Outer Sheath | Black PVC Material |
Temperature Range (Flexible) | - 50 C to +700 C |
Temperature Range (Fixed) | - 400 C to +800 C |
Voltage for Testing | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 20 x Cable Diameter |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6100602 | 2C x0.5 | 9.06 | 38.19 | 136.89 |
6100603G | 3G 0.5 | 9.46 | 45.03 | 153.78 |
6100603 | 3C x0.5 | 9.46 | 45.03 | 153.78 |
6100604G | 4G 0.5 | 10.12 | 53.11 | 178.15 |
6100604 | 4C x0.5 | 10.12 | 53.11 | 178.15 |
6100605G | 5G 0.5 | 10.83 | 61.06 | 204.68 |
6100605 | 5C x0.5 | 10.83 | 61.06 | 204.68 |
6100607G | 7G 0.5 | 12.19 | 75.01 | 258.86 |
6100607 | 7C x0.5 | 12.19 | 75.01 | 258.86 |
6100612G | 12G 0.5 | 14.86 | 130.21 | 376.68 |
6100612 | 12C x0.5 | 14.86 | 130.21 | 376.68 |
6100618G | 18G 0.5 | 17.15 | 169.97 | 499.18 |
6100625G | 25G 0.5 | 19.88 | 223.07 | 631.42 |
Product Details:
Conductor | Copper |
Insulation | PVC |
Flexible applications | - 250 C to +800 C |
Fixed Installation | - 400 C to +800 C |
Test Voltage | 2.5 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 6 x Cable Diameter |
Static | 4 x Cable Diameter |
Rated Voltage(U /U) | 300/500 V |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
63319XX | 1Cx4 | 7 | 38 | 87 |
63323XX | 1Cx6 | 7.6 | 58 | 112 |
63327XX | 1Cx10 | 9.3 | 96 | 176 |
63328XX | 1Cx16 | 10.4 | 154 | 247 |
63330XX | 1Cx25 | 12.5 | 240 | 371 |
63332XX | 1Cx35 | 13.7 | 336 | 483 |
6331303G | 3G1.5 | 9.1 | 43 | 131 |
6331304G | 4G1.5 | 10 | 58 | 162 |
Product Details:
Flexible applications | - 300 C to +800 C |
Fixed Installation | - 500 C to +800 C |
Voltage for Testing | 2.5 kV |
Rated Voltage | 450/750 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6321303G | 3G1.5 | 8.5 | 39.8 | 116 |
6321303 | 3Cx1.5 | 8.5 | 39.8 | 116 |
6321304G | 4G1.5 | 9.4 | 53 | 145 |
6321603G | 3G2.5 | 10 | 66.7 | 168 |
6321603 | 3Cx2.5 | 10 | 66.7 | 168 |
6321604G | 4G2.5 | 11 | 88.9 | 211 |
6321903 | 3Cx4 | 11.4 | 143.2 | 263 |
6321904G | 4G4 | 12.5 | 143.2 | 295 |
6322303 | 3Cx6 | 13.4 | 161.3 | 337 |
6322304G | 4G6 | 14.8 | 215 | 425 |
Product Details:
Conductor | Annealed Copper Conductor Class 5 Flexible |
Outer Sheath | PVC |
Cable Type | BS EN 50525-2-11:2011 BS-6500 |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/300 V |
Number of Core | 2 Core |
Insulation Material | PVC |
Conductor Type | Solid |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max. Conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0300602 | 2 | 0.5 | 0.93 | 0.5 | 0.6 | 4.6 | 5.9 | 39 | 45 |
A0300802 | 2 | 0.75 | 1.14 | 0.5 | 0.6 | 4.9 | 6.3 | 26 | 54 |
A0300603 | 3 | 0.5 | 0.93 | 0.5 | 0.6 | 4.9 | 6.3 | 39 | 52 |
A0300803 | 3 | 0.75 | 1.14 | 0.5 | 0.6 | 5.2 | 6.7 | 26 | 63 |
Product Details:
Conductor Material | Copper |
Standard | BS EN 50525-2-11:2011 BS-6500 |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 600 C |
Part Number | Conductor Construction | Insulation Thickness Nom. | Core diameter | Core diameter | Cable diameter | |||||
Nominal Cross- Section | No. of Strands | Strand dia max. | Conductor Diameter Nom. | Min | Max | Min. | Max. | |||
mm2/AWG | Nos. | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 mm2 | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 mm2 | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Conductor | Copper Wires |
Bending Radius (Flexing) | 20 x Cable Diameter |
Static | 6 x Cable Diameter |
Rated Voltage (U /U) | 300/500 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Insulation | PVC |
Braiding | Tinned Copper Wire |
Outer Sheath | Silver Grey PVC Compound |
Temperature (Flexible) | - 50 C to +700 C |
Temperature (Fixed) | - 400 C to +800 C |
Test Voltage (Core/Core) | 4 kV |
Test Voltage (Core/Shielding) | 2 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6150602 | 2 C x 0 .5 | 6 .3 1 | 3 6 .0 0 | 6 7 .3 5 |
6150603G | 3 G 0 .5 | 6 .6 2 | 4 3 .0 0 | 7 7 .1 0 |
6150603 | 3 C x 0 .5 | 6 .6 2 | 4 3 .0 0 | 7 7 .1 0 |
6150604G | 4 G 0 .5 | 7 .1 2 | 4 9 .0 0 | 8 8 .7 4 |
6150604 | 4 C x 0 .5 | 7 .1 2 | 4 9 .0 0 | 8 8 .7 4 |
6150605G | 5 G 0 .5 | 7 .6 6 | 5 7 .0 0 | 1 0 3 .5 4 |
6150605 | 5 C x 0 .5 | 7 .6 6 | 5 7 .0 0 | 1 0 3 .5 4 |
6150607G | 7 G 0 .5 | 8 .2 4 | 6 9 .0 0 | 1 2 2 .6 0 |
6150607 | 7 C x 0 .5 | 8 .2 4 | 6 9 .0 0 | 1 2 2 .6 0 |
6150612G | 1 2 G 0 .5 | 9 .9 8 | 1 0 4 .0 0 | 1 9 5 .2 7 |
6150612 | 1 2 C x 0 .5 | 9 .9 8 | 1 0 4 .0 0 | 1 9 5 .2 7 |
Product Details:
Conductor | Copper |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Braiding | Tinned Copper Wire |
Temperature Range (Flexible) | - 300 C to +700 C |
Fixed Installation | - 400 C to +800 C |
Voltage for Testing | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Flexing | 10 x Cable Diameter |
Static | 4 x Cable Diameter |
Rated Voltage(U /U) | 300/500 V |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6140602 | 2 C x0 .5 | 7 .0 1 | 2 9 .1 0 | 7 5 .8 4 |
6140603G | 3 G 0 .5 | 7 .3 2 | 3 5 .1 0 | 8 5 .5 6 |
6140603 | 3 C x0 .5 | 7 .3 2 | 3 5 .1 0 | 8 5 .5 6 |
6140604G | 4 G 0 .5 | 8 .0 2 | 4 1 .4 0 | 1 0 2 .7 0 |
6140604 | 4 C x0 .5 | 8 .0 2 | 4 1 .4 0 | 1 0 2 .7 0 |
6140605G | 5 G 0 .5 | 8 .5 6 | 4 8 .0 0 | 1 1 7 .9 5 |
6140607G | 7 G 0 .5 | 9 .1 4 | 5 9 .9 0 | 1 3 9 .0 0 |
6140612G | 1 2 G 0 .5 | 1 0 .8 8 | 9 1 .4 0 | 2 1 5 .9 1 |
6140802 | 2 C x0 .7 5 | 7 .8 3 | 3 5 .4 0 | 9 3 .7 1 |
6140803G | 3 G 0 .7 5 | 8 .2 0 | 4 3 .8 0 | 1 0 7 .0 9 |
6140803 | 3 C x0 .7 5 | 8 .2 0 | 4 3 .8 0 | 1 0 7 .0 9 |
Product Details:
Insulation Material | PVC |
Number of Core | 2 Core |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 600 C |
Part Number | Conductor Construction | Insulation Thickness Nom. | Core diameter | Core diameter | Cable diameter | |||||
Nominal Cross- Section | No. of Strands | Strand dia max. | Conductor Diameter Nom. | Min | Max | Min. | Max. | |||
mm2/AWG | Nos. | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 mm2 | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 mm2 | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Conductor | Annealed copper conductor |
Insulation | PVC |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 900 C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall dimension (Height x Width) | Max. Conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0370802 | 2 | 0.75 | 0.93 | 0.6 | 0.8 | 3.7 X 6.0 | 4.5 X 7.2 | 26 | 54 |
A0371002 | 2 | 1 | 1.14 | 0.6 | 0.8 | 3.9 X 6.2 | 4.7 X 7.5 | 19.5 | 61 |
A0371302 | 2 | 1.5 | 1.32 | 0.7 | 0.8 | 4.2 X 7.0 | 5.2 X 8.6 | 13.3 | 80 |
Product Details:
Conductor | Annealed copper |
Insulation | PVC |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 700 deg C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max. Conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0330802 | 2 | 0.75 | 1.14 | 0.6 | 0.8 | 3.7 X 6.0 | 4.5 X 7.2 | 26 | 54 |
A0331002 | 2 | 1 | 1.32 | 0.6 | 0.8 | 3.9 X 6.2 | 4.7 X 7.5 | 19.5 | 61 |
A0331302 | 2 | 1.5 | 1.6 | 0.7 | 0.8 | 4.2 X 7.0 | 5.2 X 8.6 | 13.3 | 80 |
Product Details:
Conductor Material | Copper |
Insulation | PVC Compound |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 450/750 V |
Max. Operating temperature | 700 C |
Part Number | Size | Conductor diameter | Thickness of insulation | Overall diameter | Max. conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||
mm2 | mm | mm | mm | mm | Ω/Km | Kg/Km | |
A04713XX | 1.5 | 1.6 | 0.7 | 2.8 | 3.4 | 13.3 | 23 |
A04716XX | 2.5 | 2 | 0.8 | 3.4 | 4.1 | 7.98 | 35 |
A04719XX | 4 | 2.6 | 0.8 | 3.9 | 4.8 | 4.95 | 49 |
A04723XX | 6 | 3.3 | 0.8 | 4.4 | 5.3 | 3.3 | 68 |
A04727XX | 10 | 4.2 | 1 | 5.7 | 6.8 | 1.91 | 112 |
Product Details:
Conductor | Annealed copper conductor, class 5 |
Insulation | PVC Compound |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 450/750 V |
Max. Operating temperature | 700 C |
Part Number | Size | Conductor diameter | Thickness of insulation | Conductor diameter | Overall diameter | Max conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | |||||||
mm2 | mm | mm | mm | mm | mm | Ω/Km | Kg/Km | |
A04113XX | 1.5 | 1.6 | 0.7 | 0.7 | 2.8 | 3.4 | 13.3 | 23 |
A04116XX | 2.5 | 2 | 0.8 | 0.8 | 3.4 | 4.1 | 7.98 | 35 |
A04119XX | 4 | 2.6 | 0.8 | 0.8 | 3.9 | 4.8 | 4.95 | 49 |
A04123XX | 6 | 3.3 | 0.8 | 0.8 | 4.4 | 5.3 | 3.3 | 68 |
A04127XX | 10 | 4.2 | 1 | 1 | 5.7 | 6.8 | 1.91 | 112 |
Product Details:
Conductor | Copper |
Insulation | PVC |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 900 C |
Part Number | Size | Conductor diameter | Thickness of insulation | overall diameter | Max conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||
mm2 | mm | mm | mm | mm | Ω/Km | Kg/Km | |
A05006XX | 0.5 | 0.93 | 0.6 | 2.1 | 2.5 | 39 | 11 |
A05008XX | 0.75 | 1.14 | 0.6 | 2.2 | 2.7 | 26 | 14 |
A05010XX | 1 | 1.32 | 0.6 | 2.4 | 2.8 | 19.5 | 16 |
Product Details:
Conductor Material | Copper |
Insulation | PVC |
Standard | BS EN 50525-2-11:2011 BS-6500 |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 700 C |
Part Number | Size | Conductor diameter | Thickness of insulation | Overall diameter | Max. conductor resistance at a 200C | Weight approx. | |
Minimum | Maximum | ||||||
mm2 | mm | mm | mm | mm | Ω/Km | Kg/Km | |
A04406XX | 0.5 | 0.5 | 0.6 | 2.1 | 2.5 | 39 | 11 |
A04408XX | 0.75 | 0.75 | 0.6 | 2.2 | 2.7 | 26 | 14 |
A04410XX | 1 | 1 | 0.6 | 2.4 | 2.8 | 19.5 | 16 |
Product Details:
Insulation | PVC Compound |
Braiding | Protected Steel Wire |
Temperature Range (Flexing) | - 50 C to +700 C |
Fixed Installation | - 400 C to +800 C |
Voltage for Testing | 4 kV |
Bending Radius (Flexing) | 20 x Cable Diameter |
Static | 6 x Cable Diameter |
Rated Voltage | 300/500 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6110602 | 2C x0.5 | 7.76 | 9.63 | 81.14 |
6110603G | 3G 0.5 | 8.1 | 14.45 | 89.54 |
6110604G | 4G 0.5 | 8.45 | 19.17 | 102.51 |
6110605G | 5G 0.5 | 9.15 | 23.96 | 118.52 |
6110607G | 7G 0.5 | 9.69 | 33.64 | 133.39 |
6110610G | 10G 0.5 | 11.62 | 48.06 | 179.82 |
6110612G | 12G 0.5 | 11.86 | 58.05 | 205.66 |
6110614G | 14G 0.5 | 12.49 | 67.1 | 231.07 |
611068G | 18G 0.5 | 13.85 | 86.27 | 283.85 |
6110621G | 21G 0.5 | 14.85 | 101.12 | 329.23 |
Product Details:
Insulation Material | PVC |
Number of Core | 2 Core |
Conductor | Annealed copper conductor, class 5 flexible |
Insulation | Cross linked elastomeric compound Type EI 7 |
Outer Sheath | Cross linked elastomeric compound type EM 7 to EN 50363-2-1 |
Cable Type | BS EN 50525-2-11:2011 BS-6500 |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 450/750 V |
Max. Operating temperature | 900 C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max conductor resistance 0 at 20 C | Weight approx. | |||
Single layer | Double layer | Minimum | Maximum | ||||||||
Inner layer | Outer layer | ||||||||||
Nos | mm2 | mm | mm | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0241306 | 6 | 1.5 | 1.6 | 0.8 | 2.6 | 1 | 14.5 | 13.4 | 17.2 | 13.3 | 347 |
A0241307 | 7 | 1.5 | 1.6 | 0.8 | 2.6 | 1 | 1.6 | 14.7 | 18.7 | 13.3 | 373 |
Product Details:
Conductor Material | Annealed copper |
Insulation | PVC Type TI 2 |
Outer Sheath | PVC Type TM 2 |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 300/500 V |
Max. Operating temperature | 700 C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall diameter | Max. Conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0320802 | 2 | 0.75 | 1.14 | 0.6 | 0.8 | 5.7 | 7.2 | 26 | 66 |
A0321002 | 2 | 1 | 1.32 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 75 |
A0321302 | 2 | 1.5 | 1.6 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 97 |
A0321602 | 2 | 2.5 | 2 | 0.8 | 1 | 8.4 | 10.6 | 7.98 | 148 |
Product Details:
Conductor | Finely Stranded tinned Copper Wires |
Rated Voltage (U /U) | 600/1000 V |
Specific Insulation Resistance | Greater than 1 G Ohm x cm |
Insulation | Electron Beam Cross Linked Polyolefin |
Cores | Twisted |
Temperature Range | - 250 C to +1250 C |
Test Voltage | 3 kV |
Protective Conductor(PC) | G- With green/yellow PC |
Bending Radius (Flexing) | 10 x Cable Diameter |
Bending Radius (Static) | 5 x Cable Diameter |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6391303G | 3G 1 .5 | 10.92 | 43 | 173.14 |
6391304G | 4 G 1 .5 | 11.8 | 58 | 208.26 |
6391305G | 5 G 1 .5 | 12.75 | 72 | 246.25 |
6391603G | 3 G 2 .5 | 12.75 | 72 | 246.6 |
6391604G | 4 G 2 .5 | 13.8 | 96 | 297.9 |
6391605G | 5 G 2 .5 | 14.94 | 120 | 354.66 |
6391607G | 7 G 2 .5 | 16.15 | 168 | 435.89 |
6391612G | 1 2 G 2 .5 | 20.85 | 288 | 732.52 |
Product Details:
Conductor | Annealed copper conductor |
Insulation | Cross-linked elastomeric compound Type EI 4 |
Outer Sheath | Cross-linked elastomeric compound type EM 2 to EN 50363-2-1 |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage(u /u) | 450/750 V |
Part Number | Conductor Construction | Insulation Thickness Nom. | Core diameter | Core diameter | Cable diameter | |||||
Nominal Cross- Section | No. of Strands | Strand dia max. | Conductor Diameter Nom. | Min | Max | Min. | Max. | |||
mm2/AWG | Nos. | mm | mm | mm | mm | mm | mm | mm | mm | |
A0710601P* | 0.5 mm2 | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
A0716001P | 0.8 mm2 | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718101P | 18 AWG | 19 | 0.23 | 1.16 | 0.4 | 2.03 | 3.05 | 1 | 5.3 | 8.2 |
A0718201P | 20 AWG | 7 | 0.32 | 0.98 | 0.4 | 1.9 | 2.8 | 0.8 | 5.08 | 7.6 |
Product Details:
Temperature Range | - 250 C to +700 C |
Test voltage | 2 kV |
Conductor resistance | EN 60228 |
Working voltage | 300/500 V |
Max. Operating temperature | 900 C |
Part Number | Number of Cores | Size | Conductor diameter | Thickness of insulation | Thickness of Sheath | Overall dimension (Height x Width) | Max. Conductor resistance at 200C | Weight approx. | |
Minimum | Maximum | ||||||||
Nos. | mm2 | mm | mm | mm | mm | mm | Ω/km | Kg/Km | |
A0330802 | 2 | 0.75 | 1.14 | 0.6 | 0.8 | 3.7 X 6.0 | 4.5 X 7.2 | 26 | 54 |
A0331002 | 2 | 1 | 1.32 | 0.6 | 0.8 | 3.9 X 6.2 | 4.7 X 7.5 | 19.5 | 61 |
A0331302 | 2 | 1.5 | 1.6 | 0.7 | 0.8 | 4.2 X 7.0 | 5.2 X 8.6 | 13.3 | 80 |
Product Details:
Number of Core | 1 |
Conductor Material | Copper |
Insulation | PVC Compound |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Braiding | Galvanized Steel Wires |
Temperature range (Flexible) | - 50 C to +700 C |
Fixed Installation | - 400 C to +800 C |
Test Voltage | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 20 x Cable Diameter |
Bending Radius (Static) | 6 x Cable Diameter |
Rated Voltage | 300/500 V |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Total Weight Kg/Km approx. |
6040602 | 2C x 0.5 | 7.7 | 9.6 | 84 |
6040603G | 3 G 0.5 | 8 | 14.4 | 93 |
6040604G | 4 G 0.5 | 8.6 | 19.2 | 108 |
6040605G | 5 G 0.5 | 9.2 | 24 | 120 |
6040607G | 7 G 0.5 | 10 | 33.6 | 148 |
6040608G | 8 G 0.5 | 10.7 | 38 | 169 |
6040610G | 10 G 0.5 | 11.9 | 48 | 191 |
6040612G | 12 G 0.5 | 12.3 | 58 | 213 |
6040614G | 14 G 0.5 | 13 | 67 | 242 |
Product Details:
Conductor | Copper |
Rated Voltage(U /U) | 600/1000 V |
Specific Insulation Resistance | Greater than 20 G Ohm x cm |
Insulation | PVC compound |
Outer Sheath | Black PVC Material |
Temperature Range (Flexible) | - 50 C to +700 C |
Fixed | - 400 C to +800 C |
Voltage for Testing | 4 kV |
Protective Conductor(PC) | G-With green/yellow PC |
Bending Radius (Flexing) | 15 x Cable Diameter |
Static | 4 x Cable Diameter |
Part Number | Number of Cores and mm2 Per Conductor | Outer Diameter in mm approx. | Copper Index Kg/Km | Weight Kg/Km approx. |
6080802 | 2C x0.75 | 7.48 | 14.42 | 77.09 |
6080803G | 3G 0.75 | 7.72 | 21.63 | 86.94 |
6080803 | 3C x0.75 | 7.72 | 21.63 | 86.94 |
6080804G | 4G 0.75 | 8.43 | 28.95 | 111.47 |
6080804 | 4C x0.75 | 8.43 | 28.95 | 111.47 |
6080805G | 5G 0.75 | 9.2 | 36.03 | 134.17 |
608087G | 7G 0.75 | 10.72 | 50.96 | 184.72 |
6080812G | 12G 0.75 | 13.21 | 86.02 | 253.93 |
6080818G | 18G 0.75 | 15.5 | 130.03 | 360.22 |
6080825G | 25G 0.75 | 18.34 | 180.08 | 452.75 |
6080834G | 34G 0.75 | 20.48 | 245.14 | 620.49 |
6080841G | 41G 0.75 | 21.75 | 295.9 | 718.43 |