Siechem is India’s No.1 leading manufacturer & exporter of Instrumentation Cables. These cables are manufactured with EC grade copper conductor with PVC/PE for insulation and outer sheath with shielding or screened with Aluminum mylar tape plus drain wire or copper wire braiding to achieve excellent noise immunity and very low electromagnetic interference.
Product Details:
Brand | Siechem |
Length | 12mm |
Power/Voltage | 600 V |
Conductor | Annealed Tinned copper as per ASTM B33 |
Insulation | EBXL-XLPE 120 C |
Temperature Rating | 120 deg C |
Part Number | Conductor Size | Conductor Strand | Insulation Thickness (Normal) | Cable Diameter (Normal) | Copper Index (approx) | Cable Weight (approx) |
(AWG) | mm | mm | kg/km | kg/km | ||
952 79 XX | 14 | 7/0.615 | 1.14 | 4.14 | 19 | 33 |
952 78 XX | 12 | 7/0.775 | 1.14 | 4.62 | 30 | 47 |
952 77 XX | 10 | 7/0.978 | 1.14 | 5.21 | 48 | 68 |
952 76 XX | 8 | 07/01/34 | 1.52 | 6.76 | 76 | 110 |
952 75 XX | 6 | 07/01/54 | 1.52 | 7.7 | 121 | 162 |
952 74 XX | 4 | 07/01/61 | 1.52 | 8.89 | 192 | 242 |
952 73 XX | 2 | 07/02/74 | 1.52 | 10.4 | 305 | 368 |
Product Details:
Brand | Siechem |
Length | 18mm |
Power/Voltage | 600 V |
Temperature Rating | 120 deg C |
Outer sheath | Heavy-duty chlorosulfonated polyethylene (CSPE) |
Conductor | Annealed Tinned copper as per ASTM B33 |
Part Number | No.of Conductor | Conductor Size | Conductor Strand | Insulation Thickness | Jacket Thickness | Cable Diameter | Copper Index (approx.) | Cable Weight (approx.) |
mm | mm | mm | kg/km | kg/km | ||||
95581XX | 2/C | 18 | 7/0.386 | 0.64 | 1.14 | 7.75 | 15 | 76 |
95581XX | 3/C | 18 | 7/0.386 | 0.64 | 1.14 | 8 | 23 | 85 |
95581XX | 4/C | 18 | 7/0.386 | 0.64 | 1.14 | 8.64 | 30 | 106 |
95581XX | 5/C | 18 | 7/0.386 | 0.64 | 1.14 | 9.4 | 38 | 118 |
95581XX | 7/C | 18 | 7/0.386 | 0.64 | 1.14 | 10.16 | 53 | 146 |
Product Details:
Length | 10mm |
Power/Voltage | 500V |
Product Details:
Minimum Order Quantity | 5000 Meter |
Brand | Siechem |
Core | Single and Multi |
Conductor | Annealed Tinned copper as per ASTM B33 |
Insulation | EBXL-XLPE |
Outer sheath | Heavy-duty chlorous phonated polyethylene |
Temperature Rating | 120 deg C |
Product Details:
Length | 10mm |
Power/Voltage | 500V |
Cable Type | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 |
Normal Thickness of sheath/ Bedding (mm) | 1.1 | 1.1 | 1.2 | 1.2 | 1.3 | 1.3 | 1.5 | 1.5 | 1.5 | 1.5 | 1.7 | 1.7 | 2.2 | 2.2 |
Normal Diameter over Sheath/ Bedding (mm) | 11 | 11 | 14.2 | 14.2 | 20.1 | 20.1 | 23.5 | 23.5 | 26.3 | 26.3 | 31.3 | 31.3 | 40.7 | 40.7 |
Normal Size of Armour wire (mm) | 0.9 | 1.25 | 1.6 | 1.6 | 1.6 | 2 | 2.5 |
Product Details:
Length | 12mm |
Power/Voltage | 600 V |
Part Number | No.of Conductor | Conductor Size | Conductor Strand | Insulation Thickness | Jacket Thickness | Cable Diameter | Copper Index (approx.) | Cable Weight (approx.) |
mm | mm | mm | kg/km | kg/km | ||||
95581XX | 2/C | 18 | 7/0.386 | 0.64 | 1.14 | 7.75 | 15 | 76 |
95581XX | 3/C | 18 | 7/0.386 | 0.64 | 1.14 | 8 | 23 | 85 |
95581XX | 4/C | 18 | 7/0.386 | 0.64 | 1.14 | 8.64 | 30 | 106 |
95581XX | 5/C | 18 | 7/0.386 | 0.64 | 1.14 | 9.4 | 38 | 118 |
95581XX | 7/C | 18 | 7/0.386 | 0.64 | 1.14 | 10.16 | 53 | 146 |
3.4/5
Reviewed by 9 Users
Most Relevant Reviews